﻿<?xml version="1.0" encoding="utf-8"?><Regulation regulation-type="SOR" xml:lang="en" startdate="20070701"><Identification Code="id=&quot;&quot;" hasPreviousVersion="true"><LimsAuthority><Alpha>C-10.15</Alpha><AuthorityTitle>Canada Shipping Act, 2001</AuthorityTitle></LimsAuthority><InstrumentNumber>SOR/90-264</InstrumentNumber><RegistrationDate><Date><YYYY>1990</YYYY><MM>5</MM><DD>1</DD></Date></RegistrationDate><ConsolidationDate><Date><YYYY>2013</YYYY><MM>01</MM><DD>28</DD></Date></ConsolidationDate><LastModifiedDate><Date><YYYY>2006</YYYY><MM>10</MM><DD>5</DD></Date></LastModifiedDate><EnablingAuthority Code="id=&quot;&quot;,ea=&quot;&quot;"><XRefExternal reference-type="act">CANADA SHIPPING ACT, 2001</XRefExternal></EnablingAuthority><ShortTitle Code="id=&quot;&quot;,st=&quot;&quot;">Marine Machinery Regulations</ShortTitle><LongTitle Code="id=&quot;&quot;,lt=&quot;&quot;">Regulations Respecting the Construction, Installation and Inspection of Marine Machinery</LongTitle><RegulationMakerOrder><RegulationMaker>P.C.</RegulationMaker><OrderNumber>1990-744 </OrderNumber><Date><YYYY> 1990</YYYY><MM>4</MM><DD>26</DD></Date></RegulationMakerOrder></Identification><Order Code="od=&quot;&quot;"><Provision format-ref="indent-1-0" language-align="yes" list-item="no" Code="od=&quot;&quot;,pv=&quot;&quot;,nb=&quot;1&quot;"><Text>His Excellency the Governor General in Council, on the recommendation of the Minister of Transport, pursuant to section 338<FootnoteRef idref="footnote1_e">*</FootnoteRef> of the <XRefExternal reference-type="act" link="S-9">Canada Shipping Act</XRefExternal>, is pleased hereby to revoke the <XRefExternal reference-type="regulation">Liquified Petroleum Gas Regulations</XRefExternal>, C.R.C., c. 1437, the <XRefExternal reference-type="regulation">Steamship Machinery Construction Order</XRefExternal>, C.R.C., c. 1490, the <XRefExternal reference-type="regulation">Steamship Machinery Construction Regulations</XRefExternal>, C.R.C., c. 1491 and the <XRefExternal reference-type="regulation">Steamship Machinery Inspection Regulations</XRefExternal>, C.R.C., c. 1492, and to make the annexed <XRefExternal reference-type="regulation">Regulations respecting the construction, installation and inspection of marine machinery</XRefExternal>, in substitution therefor.</Text><Footnote id="footnote1_e" placement="page" status="official"><Label>*</Label><Text>R.S., c. 6 (3rd Supp.), s. 47</Text></Footnote></Provision></Order><Body><Heading Code="ga=&quot;s_1&quot;,h1=&quot;&quot;" level="1"><TitleText Code="ga=&quot;s_1&quot;,h1=&quot;&quot;,t1=&quot;&quot;,nb=&quot;1&quot;">SHORT TITLE</TitleText></Heading><Section Code="se=&quot;1&quot;"><Label>1.</Label><Text>These Regulations may be cited as the <XRefExternal reference-type="regulation" link="SOR-90-264">Marine Machinery Regulations</XRefExternal>.</Text></Section><Heading Code="ga=&quot;s_2&quot;,h1=&quot;&quot;" level="1"><TitleText Code="ga=&quot;s_2&quot;,h1=&quot;&quot;,t1=&quot;&quot;,nb=&quot;1&quot;">INTERPRETATION</TitleText></Heading><Section Code="se=&quot;2&quot;"><Label>2.</Label><Subsection Code="se=&quot;2&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>In these Regulations,</Text><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{Act}{Loi}&quot;"><Text><DefinedTermEn>Act</DefinedTermEn> means the <XRefExternal reference-type="act" link="S-9">Canada Shipping Act</XRefExternal>; (<DefinedTermFr>Loi</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{approved classification society}{société de classification agréée}&quot;"><Text><DefinedTermEn>approved classification society</DefinedTermEn> means the American Bureau of Shipping, Bureau Veritas (Canada), Det norske Veritas, Lloyd’s Register of Shipping or Germanischer Lloyd; (<DefinedTermFr>société de classification agréée</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{assigned working pressure}{pression de service effective}&quot;"><Text><DefinedTermEn>assigned working pressure</DefinedTermEn> means the maximum fluid pressure to which the component with the lowest design working pressure in a system may be subjected and above which the system is protected from overpressure; (<DefinedTermFr>pression de service effective</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{auxiliary steering gear}{appareil à gouverner auxiliaire}&quot;"><Text><DefinedTermEn>auxiliary steering gear</DefinedTermEn> means the arrangements provided for effecting movement of the rudder of a ship in the event of failure of the main steering gear, but does not include the rudder stock, tiller or quadrant, or the component serving the same purpose as the tiller or quadrant, or, where fitted, the automatic-pilot system; (<DefinedTermFr>appareil à gouverner auxiliaire</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{boiler}{chaudière}&quot;"><Text><DefinedTermEn>boiler</DefinedTermEn> means a plant that generates steam or hot water under pressure by means of a flame, combustion gases or electrical heating elements, and includes the superheaters, economizers, valves and components necessary for the safety and operation of the plant; (<DefinedTermFr>chaudière</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{classification society}{société de classification}&quot;"><Text><DefinedTermEn>classification society</DefinedTermEn> means a society or association for the classification of ships; (<DefinedTermFr>société de classification</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{component}{élément}&quot;"><Text><DefinedTermEn>component</DefinedTermEn> means a unit or part of a unit that is identified in rules or codes and is to be installed as part of machinery; (<DefinedTermFr>élément</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{component inspection certificate}{certificat d’inspection d’élément}&quot;"><Text><DefinedTermEn>component inspection certificate</DefinedTermEn> means a certificate referred to in section 16; (<DefinedTermFr>certificat d’inspection d’élément</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{design working pressure}{pression de service nominale}&quot;"><Text><DefinedTermEn>design working pressure</DefinedTermEn> means the maximum fluid pressure to which a component may be subjected during operating conditions; (<DefinedTermFr>pression de service nominale</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{fluid}{fluide}&quot;"><Text><DefinedTermEn>fluid</DefinedTermEn> means a gas, vapour or liquid; (<DefinedTermFr>fluide</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{fuel oil unit}{appareil à mazout}&quot;"><Text><DefinedTermEn>fuel oil unit</DefinedTermEn> means the facility, including pressure pumps, filters and heaters, dealing with oil at a pressure in excess of 180 kPa and used in the preparation of fuel oil for delivery to an oil-fired boiler or, where the oil is heated prior to delivery, to an internal combustion engine; (<DefinedTermFr>appareil à mazout</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{harmful substance}{substance nocive}&quot;"><Text><DefinedTermEn>harmful substance</DefinedTermEn> means waste as defined in the <XRefExternal reference-type="act" link="A-12">Arctic Waters Pollution Prevention Act</XRefExternal> or pollutant as defined in section 673 of the Act; (<DefinedTermFr>substance nocive</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{inspection certificate}{certificat d’inspection}&quot;"><Text><DefinedTermEn>inspection certificate</DefinedTermEn> means an inspection certificate referred to in Part V of the Act; (<DefinedTermFr>certificat d’inspection</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{inspector}{inspecteur}&quot;"><Text><DefinedTermEn>inspector</DefinedTermEn> means a person appointed as a steamship inspector pursuant to section 301 of the Act; (<DefinedTermFr>inspecteur</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{launch}{chaloupe}&quot;"><Text><DefinedTermEn>launch</DefinedTermEn> means a ship that has an open cockpit or a cockpit covered by a light trunk cabin in which passengers may be carried; (<DefinedTermFr>chaloupe</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{length}{longueur}&quot;"><Text><DefinedTermEn>length</DefinedTermEn> means</Text><Paragraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{length}{longueur}&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>in the case of a Safety Convention passenger ship, the horizontal distance measured between perpendiculars erected at the extreme ends of the deepest subdivision load line,</Text></Paragraph><Paragraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{length}{longueur}&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>in the case of a ship, other than a Safety Convention passenger ship, that is required to be registered pursuant to the Act,</Text><Subparagraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{length}{longueur}&quot;,p1=&quot;b&quot;,p2=&quot;i&quot;"><Label>(i)</Label><Text>the distance measured from the fore-part of the uppermost end of the stem to the aft side of the head of the stern post, except that where a stern post is not fitted to the ship, it is the distance from the fore-part of the uppermost end of the stem to the foreside of the head of the rudder stock,</Text></Subparagraph><Subparagraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{length}{longueur}&quot;,p1=&quot;b&quot;,p2=&quot;ii&quot;"><Label>(ii)</Label><Text>where the ship has no rudder stock or has a rudder stock situated outside the hull at the stern, the distance measured from the foreside of the foremost permanent structure to the aft side of the aftermost permanent structure of the ship, but not including guards or rubbing strakes, or</Text></Subparagraph><Subparagraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{length}{longueur}&quot;,p1=&quot;b&quot;,p2=&quot;iii&quot;"><Label>(iii)</Label><Text>where the ship is a double-ended ship, the distance measured from the aft side of the forward rudder stock to the foreside of the aft rudder stock, and</Text></Subparagraph></Paragraph><Paragraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{length}{longueur}&quot;,p1=&quot;c&quot;"><Label>(<Emphasis style="italic">c</Emphasis>)</Label><Text>in the case of a ship that is not required to be registered pursuant to the Act, the horizontal distance measured between perpendiculars erected at the extreme outside ends of the hull; (<DefinedTermFr>longueur</DefinedTermFr>)</Text></Paragraph></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{liquefied petroleum gas}{gaz de pétrole liquéfié}&quot;"><Text><DefinedTermEn>liquefied petroleum gas</DefinedTermEn> means a liquefied inflammable gas that is composed predominantly of hydrocarbons or mixtures of hydrocarbons such as propane, propylene, butane, butylene or butadene, and that has a Reid vapour pressure exceeding 276 kPa absolute at 38° C; (<DefinedTermFr>gaz de pétrole liquéfié</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{local steering gear control system}{système local de commande de 1‘appareil à gouverner}&quot;"><Text><DefinedTermEn>local steering gear control system</DefinedTermEn> means a system by which required rudder movements are transmitted to the steering gear power unit controls from a position within the steering gear compartment; (<DefinedTermFr>système local de commande de 1‘appareil à gouverner</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{machinery spaces}{tranche des machines}&quot;"><Text><DefinedTermEn>machinery spaces</DefinedTermEn> means machinery spaces of category A and all other spaces containing propelling machinery, steering gears, boilers, steam and internal combustion engines, generators and major electrical machinery, oil filling stations, refrigerating, stabilizing, ventilation and air-conditioning machinery, and similar spaces, and trunks to the spaces; (<DefinedTermFr>tranche des machines</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{machinery spaces of category A}{tranche des machines de catégorie A}&quot;"><Text><DefinedTermEn>machinery spaces of category A</DefinedTermEn> means</Text><Paragraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{machinery spaces of category A}{tranche des machines de catégorie A}&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>spaces that contain</Text><Subparagraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{machinery spaces of category A}{tranche des machines de catégorie A}&quot;,p1=&quot;a&quot;,p2=&quot;i&quot;"><Label>(i)</Label><Text>internal combustion-type machinery used for main propulsion or, where the aggregate of total power output is not less than 373 kW, for purposes other than main propulsion,</Text></Subparagraph><Subparagraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{machinery spaces of category A}{tranche des machines de catégorie A}&quot;,p1=&quot;a&quot;,p2=&quot;ii&quot;"><Label>(ii)</Label><Text>an oil-fired boiler, or</Text></Subparagraph><Subparagraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{machinery spaces of category A}{tranche des machines de catégorie A}&quot;,p1=&quot;a&quot;,p2=&quot;iii&quot;"><Label>(iii)</Label><Text>a fuel oil unit, and</Text></Subparagraph></Paragraph><Paragraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{machinery spaces of category A}{tranche des machines de catégorie A}&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>trunks to spaces referred to in paragraph (<Emphasis style="italic">a</Emphasis>); (<DefinedTermFr>tranche des machines de catégorie A</DefinedTermFr>)</Text></Paragraph></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{main steering gear}{appareil à gouverner principal}&quot;"><Text><DefinedTermEn>main steering gear</DefinedTermEn> means the main steering gear power unit and actuator by which torque is applied to the rudder stock for the purposes of effecting movement of the rudder to steer a ship; (<DefinedTermFr>appareil à gouverner principal</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{major repairs}{réparations majeures}&quot;"><Text><DefinedTermEn>major repairs</DefinedTermEn> means repairs or alterations to machinery that substantially alter the capacity, size or type of the machinery; (<DefinedTermFr>réparations majeures</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{material test certificate}{certificat d’essai de matériau}&quot;"><Text><DefinedTermEn>material test certificate</DefinedTermEn> means a certificate referred to in section 10; (<DefinedTermFr>certificat d’essai de matériau</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{periodic general inspection}{inspection périodique générale}&quot;"><Text><DefinedTermEn>periodic general inspection</DefinedTermEn> means a periodic general inspection described in subsection 19(2); (<DefinedTermFr>inspection périodique générale</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{periodic special inspection}{inspection périodique spéciale}&quot;"><Text><DefinedTermEn>periodic special inspection</DefinedTermEn> means a periodic special inspection described in subsection 20(1); (<DefinedTermFr>inspection périodique spéciale</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{pressure vessel}{récipient sous pression}&quot;"><Text><DefinedTermEn>pressure vessel</DefinedTermEn> means a boiler or an unfired pressure vessel; (<DefinedTermFr>récipient sous pression</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{remote steering gear control system}{système de commande à distance de l’appareil à gouverner}&quot;"><Text><DefinedTermEn>remote steering gear control system</DefinedTermEn> means the system by which required rudder movements are transmitted to the steering gear power unit controls from the bridge or another location in a ship, excluding the steering gear compartment; (<DefinedTermFr>système de commande à distance de l’appareil à gouverner</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{rudder actuator}{actionneur de gouvernail}&quot;"><Text><DefinedTermEn>rudder actuator</DefinedTermEn> means a unit transmitting torque to a rudder stock</Text><Paragraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{rudder actuator}{actionneur de gouvernail}&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>through an externally connected tiller, quadrant or similar component, or</Text></Paragraph><Paragraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{rudder actuator}{actionneur de gouvernail}&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>directly through an integrally housed vane or similar component; (<DefinedTermFr>actionneur de gouvernail</DefinedTermFr>)</Text></Paragraph></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{rules or codes}{règles ou codes}&quot;"><Text><DefinedTermEn>rules or codes</DefinedTermEn> means rules, regulations or codes relating to the construction, installation and inspection of marine machinery, issued by an approved classification society; (<DefinedTermFr>règles ou codes</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{shipside door-operating mechanism}{mécanisme de manoeuvre des portes de muraille}&quot;"><Text><DefinedTermEn>shipside door-operating mechanism</DefinedTermEn> means machinery employed in the opening and closing of a hull door, visor or roll on/roll off ramp of a ship, but does not include the door, visor or ramp or any locking device; (<DefinedTermFr>mécanisme de manoeuvre des portes de muraille</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{steering gear power unit}{groupe moteur d’appareil à gouverner}&quot;"><Text><DefinedTermEn>steering gear power unit</DefinedTermEn> means</Text><Paragraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{steering gear power unit}{groupe moteur d’appareil à gouverner}&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>in the case of an electric steering gear, an electric motor and its associated electrical arrangements,</Text></Paragraph><Paragraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{steering gear power unit}{groupe moteur d’appareil à gouverner}&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>in the case of an electro-hydraulic steering gear, an electric motor, and its associated electrical arrangements and the connected hydraulic pump, and</Text></Paragraph><Paragraph Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{steering gear power unit}{groupe moteur d’appareil à gouverner}&quot;,p1=&quot;c&quot;"><Label>(<Emphasis style="italic">c</Emphasis>)</Label><Text>in the case of a hydraulic steering gear, the driving engine and connected hydraulic pump; (<DefinedTermFr>groupe moteur d’appareil à gouverner</DefinedTermFr>)</Text></Paragraph></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{test pressure}{pression d’essai}&quot;"><Text><DefinedTermEn>test pressure</DefinedTermEn> means the maximum pressure to which the fluid in a component or system may be subjected during inspection; (<DefinedTermFr>pression d’essai</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{unfired pressure vessel}{récipient sous pression non chauffé}&quot;"><Text><DefinedTermEn>unfired pressure vessel</DefinedTermEn> means a container subjected to internal or external pressure, where the pressure is produced without the application of heat from an external source or by the application of heat from an indirect source or by any combination thereof, and includes condensers, evaporators, air receivers, hydro-pneumatic tanks, hydraulic accumulators, heat exchangers and similar components, but does not include cooling or heating spaces of engines, pumps, compressors, piping and similar components; (<DefinedTermFr>récipient sous pression non chauffé</DefinedTermFr>)</Text></Definition><Definition Code="se=&quot;2&quot;,ss=&quot;1&quot;,df=&quot;{windlass}{guindeau}&quot;"><Text><DefinedTermEn>windlass</DefinedTermEn> means the machinery and arrangements principally employed in the lowering and raising of the anchors of a ship, but does not include the anchors and cables. (<DefinedTermFr>guindeau</DefinedTermFr>)</Text></Definition></Subsection><Subsection Code="se=&quot;2&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>The units of measurement used in these Regulations are as defined in the <Emphasis style="italic">Metric Practice Guide</Emphasis> published by the Canadian Standards Association.</Text></Subsection><Subsection Code="se=&quot;2&quot;,ss=&quot;3&quot;"><Label>(3)</Label><Text>Unless specifically stated otherwise, all prescribed pressures are gauge pressures.</Text></Subsection><HistoricalNote><ul><li>SOR/2002-428, s. 1.</li></ul></HistoricalNote></Section><Heading Code="ga=&quot;s_3&quot;,h1=&quot;&quot;" level="1"><TitleText Code="ga=&quot;s_3&quot;,h1=&quot;&quot;,t1=&quot;&quot;,nb=&quot;1&quot;">APPLICATION</TitleText></Heading><Section Code="se=&quot;3&quot;"><Label>3.</Label><Subsection Code="se=&quot;3&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>Subject to subsection (2), these Regulations apply in respect of every ship as defined in Part XV of the Act.</Text></Subsection><Subsection Code="se=&quot;3&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>These Regulations do not apply in respect of a pleasure yacht or a non-passenger, non-self-propelled ship, except in respect of</Text><Paragraph Code="se=&quot;3&quot;,ss=&quot;2&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>propulsion system boilers on board a pleasure yacht, where the yacht is in excess of five tons gross tonnage; and</Text></Paragraph><Paragraph Code="se=&quot;3&quot;,ss=&quot;2&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>boilers and compressed air receivers on board a non-passenger, non-self-propelled ship carrying a crew where the ship</Text><Subparagraph Code="se=&quot;3&quot;,ss=&quot;2&quot;,p1=&quot;b&quot;,p2=&quot;i&quot;"><Label>(i)</Label><Text>may operate or ply on voyages more than 15 miles from land, or</Text></Subparagraph><Subparagraph Code="se=&quot;3&quot;,ss=&quot;2&quot;,p1=&quot;b&quot;,p2=&quot;ii&quot;"><Label>(ii)</Label><Text>does not operate or ply on voyages more than 15 miles from land and the boilers or compressed air receivers have an assigned working pressure in excess of 103 kPa.</Text></Subparagraph></Paragraph></Subsection></Section><Heading Code="ga=&quot;s_4&quot;,h1=&quot;&quot;" level="1"><TitleText Code="ga=&quot;s_4&quot;,h1=&quot;&quot;,t1=&quot;&quot;,nb=&quot;1&quot;">CONSTRUCTION AND INSTALLATION STANDARDS</TitleText></Heading><Section Code="se=&quot;4&quot;"><Label>4.</Label><Subsection Code="se=&quot;4&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>Any machinery referred to in Schedules I to XV that is constructed after the coming into force of these Regulations shall be constructed and installed in a ship in accordance with the following standards or specifications in force at the time the construction is commenced:</Text><Paragraph Code="se=&quot;4&quot;,ss=&quot;1&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>the standards or specifications in the rules or codes under which the machinery is being constructed; and</Text></Paragraph><Paragraph Code="se=&quot;4&quot;,ss=&quot;1&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>the design specifications set out in each item of Part I of the applicable schedule of Schedules I to XV and the general design specifications set out in Schedule XVI.</Text></Paragraph></Subsection><Subsection Code="se=&quot;4&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>In the event of any inconsistency between the standards or specifications referred to in paragraph (1)(<Emphasis style="italic">a</Emphasis>) and the specifications referred to in paragraph (1)(<Emphasis style="italic">b</Emphasis>), the specifications referred to in paragraph (1)(<Emphasis style="italic">b</Emphasis>) shall prevail.</Text></Subsection><Subsection Code="se=&quot;4&quot;,ss=&quot;3&quot;"><Label>(3)</Label><Text>Any machinery referred to in subsection (1) that has been constructed in accordance with the standards or specifications in rules or codes of an approved classification society may be installed in a ship in accordance with the rules or codes of another approved classification society.</Text></Subsection></Section><Section Code="se=&quot;5&quot;"><Label>5.</Label><Subsection Code="se=&quot;5&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>Subject to subsection (2), major repairs to machinery referred to in Schedules I to XV that was constructed before or after the coming into force of these Regulations, including the reinstallation of components associated with the machinery following the major repairs, shall be made in accordance with the standards or specifications referred to in subsection 4(1) in force at the time the major repairs are commenced.</Text></Subsection><Subsection Code="se=&quot;5&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>Where making major repairs in accordance with subsection (1) would be impracticable or inappropriate, the major repairs may be made in accordance with the standards or specifications relating to construction set out in the regulations in force at the time construction of the machinery commenced.</Text></Subsection></Section><Heading Code="ga=&quot;s_6&quot;,h1=&quot;&quot;" level="1"><TitleText Code="ga=&quot;s_6&quot;,h1=&quot;&quot;,t1=&quot;&quot;,nb=&quot;1&quot;">PLANS</TitleText></Heading><Section Code="se=&quot;6&quot;"><Label>6.</Label><Subsection Code="se=&quot;6&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>Subject to subsection (5), plans of machinery referred to in Schedules I to XV required by these Regulations to be inspected shall be submitted to the Board prior to the commencement of any inspection.</Text></Subsection><Subsection Code="se=&quot;6&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>Where machinery is constructed or installed after the coming into force of these Regulations, the plans shall be submitted to the Board prior to the commencement of construction or installation of the machinery, as the case may be.</Text></Subsection><Subsection Code="se=&quot;6&quot;,ss=&quot;3&quot;"><Label>(3)</Label><Text>The plans shall</Text><Paragraph Code="se=&quot;6&quot;,ss=&quot;3&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>be in quadruplicate unless the Board specifies that fewer than four plans are required, in English or French and in fully dimensioned form;</Text></Paragraph><Paragraph Code="se=&quot;6&quot;,ss=&quot;3&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>include the information set out in each item of Part II of the applicable schedule of Schedules I to XV;</Text></Paragraph><Paragraph Code="se=&quot;6&quot;,ss=&quot;3&quot;,p1=&quot;c&quot;"><Label>(<Emphasis style="italic">c</Emphasis>)</Label><Text>indicate the approved classification society in accordance with the rules or codes of which the machinery will be or was constructed or installed; and</Text></Paragraph><Paragraph Code="se=&quot;6&quot;,ss=&quot;3&quot;,p1=&quot;d&quot;"><Label>(<Emphasis style="italic">d</Emphasis>)</Label><Text>reflect the standards and specifications referred to in subsection 4(1).</Text></Paragraph></Subsection><Subsection Code="se=&quot;6&quot;,ss=&quot;4&quot;"><Label>(4)</Label><Text>The Board may require that additional information referred to in Part II of the applicable schedule of Schedules I to XV be included in the plans.</Text></Subsection><Subsection Code="se=&quot;6&quot;,ss=&quot;5&quot;"><Label>(5)</Label><Text>The plans need not be submitted to the Board if plans that conform to these Regulations for identical machinery have previously been submitted to the Board.</Text></Subsection><Subsection Code="se=&quot;6&quot;,ss=&quot;6&quot;"><Label>(6)</Label><Text>The submitted plans shall be inspected by an inspector and where the plans meet the requirements set out in paragraphs (3)(<Emphasis style="italic">a</Emphasis>) to (<Emphasis style="italic">d</Emphasis>) and subsection (4) shall be stamped to indicate that the plans comply with those requirements.</Text></Subsection></Section><Heading Code="ga=&quot;s_7&quot;,h1=&quot;&quot;" level="1"><TitleText Code="ga=&quot;s_7&quot;,h1=&quot;&quot;,t1=&quot;&quot;,nb=&quot;1&quot;">MATERIAL TESTING AND MARKING</TitleText></Heading><Section Code="se=&quot;7&quot;"><Label>7.</Label><Text>Specimen pieces of any material to be used in the construction of or repairs to machinery referred to in subsection 4(1) and required by the rules or codes under which the machinery is to be constructed to be tested prior to use shall be identified and shall, in the presence of an inspector, undergo, prior to the commencement of construction or repairs, the test set out in those rules or codes.</Text></Section><Section Code="se=&quot;8&quot;"><Label>8.</Label><Subsection Code="se=&quot;8&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>An inspector referred to in section 7 shall, prior to the commencement of a test, be provided with evidence that shows that all the material testing equipment to be used is in correct operational condition and adjustment.</Text></Subsection><Subsection Code="se=&quot;8&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>The evidence referred to in subsection (1) may consist of current reports or certificates issued by an equipment testing organization that is accredited by the Standards Council of Canada.</Text></Subsection></Section><Section Code="se=&quot;9&quot;"><Label>9.</Label><Text>On completion of the tests in the presence of an inspector, referred to in section 7, the material shall be permanently marked in the presence of that inspector with</Text><Paragraph Code="se=&quot;9&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>the information on the material test certificate set out in Schedule XVII under the heading “MARKING — MARQUES”; and</Text></Paragraph><Paragraph Code="se=&quot;9&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>the Federal Identity Symbol as printed on a stamp provided by the inspector.</Text></Paragraph></Section><Section Code="se=&quot;10&quot;"><Label>10.</Label><Text>An inspector shall issue a material test certificate in respect of a material in the form set out in Schedule XVII where</Text><Paragraph Code="se=&quot;10&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>the specimen pieces of the material meet the test requirements set out in the rules or codes referred to in section 7; and</Text></Paragraph><Paragraph Code="se=&quot;10&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>the material has been marked in accordance with section 9.</Text></Paragraph></Section><Section Code="se=&quot;11&quot;"><Label>11.</Label><Subsection Code="se=&quot;11&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>Notwithstanding sections 7 and 9, an exclusive surveyor to an approved classification society or a metallurgist certified by a provincial government or by any other authority having similar certification standards may witness the tests and marking referred to in those sections.</Text></Subsection><Subsection Code="se=&quot;11&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>Where an exclusive surveyor or metallurgist referred to in subsection (1) witnesses the tests and marking of a material,</Text><Paragraph Code="se=&quot;11&quot;,ss=&quot;2&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>the material test certificate shall include all testing information, bear the identification symbol of the employer of the exclusive surveyor or metallurgist and be signed by the exclusive surveyor or metallurgist; and</Text></Paragraph><Paragraph Code="se=&quot;11&quot;,ss=&quot;2&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>the permanent marking on the material shall include the identification symbol of the employer of the exclusive surveyor or metallurgist.</Text></Paragraph></Subsection></Section><Heading Code="ga=&quot;s_12&quot;,h1=&quot;&quot;" level="1"><TitleText Code="ga=&quot;s_12&quot;,h1=&quot;&quot;,t1=&quot;&quot;,nb=&quot;1&quot;">CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Section Code="se=&quot;12&quot;"><Label>12.</Label><Subsection Code="se=&quot;12&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>Subject to section 15, all machinery referred to in subsections 4(1) and 5(1) shall be inspected by an inspector during construction, installation and major repair.</Text></Subsection><Subsection Code="se=&quot;12&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>An inspection referred to in subsection (1) shall consist of the completion of each item set out in Part III of the applicable schedule of Schedules I to XV.</Text></Subsection></Section><Section Code="se=&quot;13&quot;"><Label>13.</Label><Text>No inspection of machinery shall be carried out unless the tests and marking referred to in sections 7 to 9 have been completed and the material test certificates referred to in section 10 or 11 have been provided to the inspector.</Text></Section><Section Code="se=&quot;14&quot;"><Label>14.</Label><Text>No pressure vessel referred to in Schedules I to III shall be inspected unless the following conditions have been met:</Text><Paragraph Code="se=&quot;14&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>the manufacturer’s construction and testing facilities have, prior to the commencement of construction of the pressure vessel in accordance with these Regulations, been inspected by an inspector and the inspector has submitted a report thereon to the Board; and</Text></Paragraph><Paragraph Code="se=&quot;14&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>the Board has determined on the basis of the report that the facilities are, in accordance with the state of the art, suitable for the construction or testing of boilers or unfired pressure vessels of Class 1, 2 or 3, as the case may be.</Text></Paragraph></Section><Section Code="se=&quot;15&quot;"><Label>15.</Label><Subsection Code="se=&quot;15&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>No inspection of standardized and mass-produced machinery is required where</Text><Paragraph Code="se=&quot;15&quot;,ss=&quot;1&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>the manufacturer has established and continuously applied, throughout the construction and testing of the machinery, quality control procedures that meet the requirements of paragraphs (2)(<Emphasis style="italic">b</Emphasis>) and (<Emphasis style="italic">c</Emphasis>); and</Text></Paragraph><Paragraph Code="se=&quot;15&quot;,ss=&quot;1&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>the manufacturer provides to the Board in respect of the machinery the following documentary information:</Text><Subparagraph Code="se=&quot;15&quot;,ss=&quot;1&quot;,p1=&quot;b&quot;,p2=&quot;i&quot;"><Label>(i)</Label><Text>the model and serial number of the machinery,</Text></Subparagraph><Subparagraph Code="se=&quot;15&quot;,ss=&quot;1&quot;,p1=&quot;b&quot;,p2=&quot;ii&quot;"><Label>(ii)</Label><Text>confirmation that materials testing was carried out and that the materials meet the requirements of the rules or codes under which the machinery was constructed,</Text></Subparagraph><Subparagraph Code="se=&quot;15&quot;,ss=&quot;1&quot;,p1=&quot;b&quot;,p2=&quot;iii&quot;"><Label>(iii)</Label><Text>confirmation that the machinery was constructed in accordance with these Regulations,</Text></Subparagraph><Subparagraph Code="se=&quot;15&quot;,ss=&quot;1&quot;,p1=&quot;b&quot;,p2=&quot;iv&quot;"><Label>(iv)</Label><Text>confirmation that the machinery was tested in accordance with these Regulations on completion of the construction, and</Text></Subparagraph><Subparagraph Code="se=&quot;15&quot;,ss=&quot;1&quot;,p1=&quot;b&quot;,p2=&quot;v&quot;"><Label>(v)</Label><Text>the permanent identification marking of the manufacturer and the location of the marking on the machinery.</Text></Subparagraph></Paragraph></Subsection><Subsection Code="se=&quot;15&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>The Board may approve the quality control procedures of a manufacturer where</Text><Paragraph Code="se=&quot;15&quot;,ss=&quot;2&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>the manufacturer has submitted to the Board full documentation covering the quality control procedures being applied, including periodic auditing arrangements;</Text></Paragraph><Paragraph Code="se=&quot;15&quot;,ss=&quot;2&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>the quality control procedures and the construction and testing facilities have been inspected</Text><Subparagraph Code="se=&quot;15&quot;,ss=&quot;2&quot;,p1=&quot;b&quot;,p2=&quot;i&quot;"><Label>(i)</Label><Text>by an inspector and the inspector has submitted a report thereon to the Board, or</Text></Subparagraph><Subparagraph Code="se=&quot;15&quot;,ss=&quot;2&quot;,p1=&quot;b&quot;,p2=&quot;ii&quot;"><Label>(ii)</Label><Text>by an exclusive surveyor to an approved classification society and the surveyor has submitted a report thereon to the approved classification society, the society has accepted the report and issued an acceptance certificate in respect of the inspection and a copy of the certificate has been submitted to the Board; and</Text></Subparagraph></Paragraph><Paragraph Code="se=&quot;15&quot;,ss=&quot;2&quot;,p1=&quot;c&quot;"><Label>(<Emphasis style="italic">c</Emphasis>)</Label><Text>the Board has determined on the basis of the documentation submitted that the manufacturer’s facilities and quality control procedures are, in accordance with the state of the art, suitable for the construction and testing of the machinery.</Text></Paragraph></Subsection></Section><Heading Code="ga=&quot;s_16&quot;,h1=&quot;&quot;" level="1"><TitleText Code="ga=&quot;s_16&quot;,h1=&quot;&quot;,t1=&quot;&quot;,nb=&quot;1&quot;">COMPONENT INSPECTION CERTIFICATE AND MARKING</TitleText></Heading><Section Code="se=&quot;16&quot;"><Label>16.</Label><Text>Subject to section 17, where an inspector has carried out a construction inspection of machinery in accordance with subsection 12(2), the inspector shall issue a component inspection certificate in the form set out in Schedule XVIII for each component of that machinery that is constructed in accordance with these Regulations.</Text></Section><Section Code="se=&quot;17&quot;"><Label>17.</Label><Text>Before issuing a component inspection certificate, an inspector shall ensure that the component is marked with the information on the certificate referred to in section 16 under the heading “MARKING — MARQUES”, including the Federal Identity Symbol.</Text></Section><Section Code="se=&quot;18&quot;"><Label>18.</Label><Subsection Code="se=&quot;18&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>The marking referred to in section 17 shall be conspicuous and not readily effaced, covered or removed, and shall be located</Text><Paragraph Code="se=&quot;18&quot;,ss=&quot;1&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>in the case of a hot-water boiler or a steam boiler, adjacent to an access or visual inspection opening;</Text></Paragraph><Paragraph Code="se=&quot;18&quot;,ss=&quot;1&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>in the case of an unfired pressure vessel, on an end plate;</Text></Paragraph><Paragraph Code="se=&quot;18&quot;,ss=&quot;1&quot;,p1=&quot;c&quot;"><Label>(<Emphasis style="italic">c</Emphasis>)</Label><Text>in the case of a shaft, on the flange rim;</Text></Paragraph><Paragraph Code="se=&quot;18&quot;,ss=&quot;1&quot;,p1=&quot;d&quot;"><Label>(<Emphasis style="italic">d</Emphasis>)</Label><Text>in the case of a propeller, on the hub; and</Text></Paragraph><Paragraph Code="se=&quot;18&quot;,ss=&quot;1&quot;,p1=&quot;e&quot;"><Label>(<Emphasis style="italic">e</Emphasis>)</Label><Text>in the case of any other component, adjacent to the manufacturer’s permanent identification marking.</Text></Paragraph></Subsection><Subsection Code="se=&quot;18&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>Where a component cannot be marked on a location referred to in subsection (1) because marking on the location would be physically impossible or unsafe or the marking would not be readily visible, the inspector may accept another suitable location for the marking.</Text></Subsection></Section><Heading Code="ga=&quot;s_19&quot;,h1=&quot;&quot;" level="1"><TitleText Code="ga=&quot;s_19&quot;,h1=&quot;&quot;,t1=&quot;&quot;,nb=&quot;1&quot;">PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Section Code="se=&quot;19&quot;"><Label>19.</Label><Subsection Code="se=&quot;19&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>No inspection, other than an inspection referred to in sections 24 and 25, shall be carried out pursuant to section 316 of the Act unless a component inspection certificate has been issued for each component.</Text></Subsection><Subsection Code="se=&quot;19&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>Where machinery referred to in Schedules I to XV is subject to an inspection referred to in subsection (1) at one year or four year intervals, an inspector shall carry out a periodic general inspection that consists of an external inspection of the machinery comprising an inspection or the completion of each item set out in Division I of Part IV of the applicable schedule of Schedules I to XV.</Text></Subsection></Section><Section Code="se=&quot;20&quot;"><Label>20.</Label><Subsection Code="se=&quot;20&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>Machinery referred to in Schedules I to XV is subject to a periodic special inspection by an inspector in accordance with subsection (2) and shall consist of an external and an internal inspection of the machinery comprising an inspection of each item set out in Subdivision I of Division II of Part IV of the applicable schedule of Schedules I to XV.</Text></Subsection><Subsection Code="se=&quot;20&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>Periodic special inspections shall be carried out</Text><Paragraph Code="se=&quot;20&quot;,ss=&quot;2&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>at the intervals set out in Subdivision II of Division II of Part IV of the applicable schedule of Schedules I to XV; and</Text></Paragraph><Paragraph Code="se=&quot;20&quot;,ss=&quot;2&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>at the time of the periodic general inspection, where during the periodic general inspection the inspector has reasonable grounds to believe that there are internal defects in the machinery.</Text></Paragraph></Subsection></Section><Section Code="se=&quot;21&quot;"><Label>21.</Label><Text>Where a periodic special inspection is required in accordance with paragraph 20(2)(<Emphasis style="italic">a</Emphasis>), a periodic general inspection shall be carried out, as soon as practicable, subsequent to the reassembly of the machinery that was inspected.</Text></Section><Section Code="se=&quot;22&quot;"><Label>22.</Label><Text>Where machinery is to be inspected in accordance with these Regulations, the ship owner shall ensure that the machinery is opened up and cleaned and the removable components are removed, as required by the inspector.</Text></Section><Heading Code="ga=&quot;s_23&quot;,h1=&quot;&quot;" level="1"><TitleText Code="ga=&quot;s_23&quot;,h1=&quot;&quot;,t1=&quot;&quot;,nb=&quot;1&quot;">CONTINUOUS PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Section Code="se=&quot;23&quot;"><Label>23.</Label><Subsection Code="se=&quot;23&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>On a written request to the Board by a ship owner, the Board may approve a system of continuous periodic special inspections where the inspection requirements referred to in paragraph 20(2)(<Emphasis style="italic">a</Emphasis>) are complied with according to a cycle in which approximately the same number of components is inspected in each 12-month period.</Text></Subsection><Subsection Code="se=&quot;23&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>An up-to-date record indicating the status of the continuous periodic special inspection of the various components on board a ship shall be maintained by the Board and a copy of the record shall be forwarded to the ship or owner of the ship, on request.</Text></Subsection><Subsection Code="se=&quot;23&quot;,ss=&quot;3&quot;"><Label>(3)</Label><Text>Where, in the course of a continuous periodic special inspection, a defect is found in a component and the nature of the defect and the operational conditions indicate that there may be a similar defect in a related or similar component on board the ship, the inspector may require that the related or similar component also be inspected during the inspection.</Text></Subsection></Section><Heading Code="ga=&quot;s_24&quot;,h1=&quot;&quot;" level="1"><TitleText Code="ga=&quot;s_24&quot;,h1=&quot;&quot;,t1=&quot;&quot;,nb=&quot;1&quot;">FOREIGN MACHINERY</TitleText></Heading><Section Code="se=&quot;24&quot;"><Label>24.</Label><Subsection Code="se=&quot;24&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>Subject to subsection (3), machinery referred to in Schedules I to XV that is installed in a foreign ship which ship has never been registered in Canada and is registered in Canada for the first time after the coming into force of these Regulations shall, prior to the ship’s service as a Canadian ship, be subject to a first periodic general inspection and a first periodic special inspection.</Text></Subsection><Subsection Code="se=&quot;24&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>Subject to subsection (3), machinery referred to in Schedules I to XV that is constructed in a foreign country and is brought into Canada for installation in a Canadian ship shall be subject to a first periodic general inspection and a first periodic special inspection prior to its use.</Text></Subsection><Subsection Code="se=&quot;24&quot;,ss=&quot;3&quot;"><Label>(3)</Label><Text>A first periodic special inspection of any machinery referred to in subsections (1) and (2) is not required where</Text><Paragraph Code="se=&quot;24&quot;,ss=&quot;3&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>a certificate is submitted to the Board showing</Text><Subparagraph Code="se=&quot;24&quot;,ss=&quot;3&quot;,p1=&quot;a&quot;,p2=&quot;i&quot;"><Label>(i)</Label><Text>that the construction and, as applicable, the installation of the machinery were inspected by an exclusive surveyor to an approved classification society,</Text></Subparagraph><Subparagraph Code="se=&quot;24&quot;,ss=&quot;3&quot;,p1=&quot;a&quot;,p2=&quot;ii&quot;"><Label>(ii)</Label><Text>that the machinery conforms to the rules or codes under which the machinery was constructed that were in force at the time the machinery was constructed, and</Text></Subparagraph><Subparagraph Code="se=&quot;24&quot;,ss=&quot;3&quot;,p1=&quot;a&quot;,p2=&quot;iii&quot;"><Label>(iii)</Label><Text>the form and location of identification symbols of the approved classification society on the machinery;</Text></Subparagraph></Paragraph><Paragraph Code="se=&quot;24&quot;,ss=&quot;3&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>in the case of machinery that has been installed in a ship, valid certificates of periodic class survey by an exclusive surveyor to an approved classification society are submitted to the Board;</Text></Paragraph><Paragraph Code="se=&quot;24&quot;,ss=&quot;3&quot;,p1=&quot;c&quot;"><Label>(<Emphasis style="italic">c</Emphasis>)</Label><Text>the inspector determines, on the basis of the first periodic general inspection,</Text><Subparagraph Code="se=&quot;24&quot;,ss=&quot;3&quot;,p1=&quot;c&quot;,p2=&quot;i&quot;"><Label>(i)</Label><Text>in the case of machinery referred to in subsection (1), that the machinery conforms to standards and specifications set out in regulations in force at the time the machinery was constructed, and</Text></Subparagraph><Subparagraph Code="se=&quot;24&quot;,ss=&quot;3&quot;,p1=&quot;c&quot;,p2=&quot;ii&quot;"><Label>(ii)</Label><Text>in the case of machinery referred to in subsection (2), that the machinery conforms to design specifications set out in regulations in force at the time the machinery was constructed; and</Text></Subparagraph></Paragraph><Paragraph Code="se=&quot;24&quot;,ss=&quot;3&quot;,p1=&quot;d&quot;"><Label>(<Emphasis style="italic">d</Emphasis>)</Label><Text>in the case of a pressure vessel, certificates of an approved classification society under the rules and codes of which the pressure, vessel was constructed, showing that the manufacturer’s construction and testing facilities were in compliance with those rules or codes, are submitted to the Board.</Text></Paragraph></Subsection><Subsection Code="se=&quot;24&quot;,ss=&quot;4&quot;"><Label>(4)</Label><Text>Where a first periodic special inspection is not required pursuant to subsection (3), a periodic special inspection shall be carried out on the due date of the next periodic special survey of the approved classification society under which the ship is classed.</Text></Subsection><Subsection Code="se=&quot;24&quot;,ss=&quot;5&quot;"><Label>(5)</Label><Text>Notwithstanding subsection 6(1), a first periodic general inspection of machinery referred to in subsection (1) may take place prior to submission of the plans of the machinery where the applicable certificates referred to in subsection (3) have been submitted to the Board.</Text></Subsection><Subsection Code="se=&quot;24&quot;,ss=&quot;6&quot;"><Label>(6)</Label><Text>Plans of machinery referred to in subsection (1) shall be submitted to the Board on a day that is not later than three months prior to the first periodic special inspection of the machinery.</Text></Subsection><Subsection Code="se=&quot;24&quot;,ss=&quot;7&quot;"><Label>(7)</Label><Text>Where, in accordance with paragraph (3)(<Emphasis style="italic">a</Emphasis>), a certificate has been submitted to the Board and the machinery bears the identification symbol of the approved classification society, the component inspection certificate set out in Schedule XVIII is not required to be issued.</Text></Subsection></Section><Section Code="se=&quot;25&quot;"><Label>25.</Label><Subsection Code="se=&quot;25&quot;,ss=&quot;1&quot;"><Label>(1)</Label><Text>Subject to subsections (2) and (3), machinery referred to in Schedules I to XV that is installed in a foreign ship that was previously registered in Canada before the coming into force of these Regulations and is re-registered in Canada after the coming into force of these Regulations shall be subject to a periodic general inspection and a periodic special inspection.</Text></Subsection><Subsection Code="se=&quot;25&quot;,ss=&quot;2&quot;"><Label>(2)</Label><Text>The periodic special inspection referred to in subsection (1) is not required where</Text><Paragraph Code="se=&quot;25&quot;,ss=&quot;2&quot;,p1=&quot;a&quot;"><Label>(<Emphasis style="italic">a</Emphasis>)</Label><Text>the inspector determines on the basis of the periodic general inspection that the machinery conforms to standards and specifications set out in regulations in force at the time the machinery was constructed; and</Text></Paragraph><Paragraph Code="se=&quot;25&quot;,ss=&quot;2&quot;,p1=&quot;b&quot;"><Label>(<Emphasis style="italic">b</Emphasis>)</Label><Text>valid certificates of periodic class survey by an exclusive surveyor to an approved classification society are submitted to the Board.</Text></Paragraph></Subsection><Subsection Code="se=&quot;25&quot;,ss=&quot;3&quot;"><Label>(3)</Label><Text>Where a periodic special inspection is not required pursuant to subsection (2), a periodic special inspection shall be carried out on the due date of the next periodic special survey of the approved classification society under which the ship is classed.</Text></Subsection></Section></Body><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;1&quot;"><ScheduleFormHeading><Label>SCHEDULE I</Label><TitleText>STEAM BOILERS HAVING A DESIGN WORKING PRESSURE EXCEEDING 350 kPa</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.34*" htmlwidth="10%" /><colspec colname="2" colwidth="89.66*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colsep="0" rowsep="1" valign="bottom" id="t5480h0">Item</entry><entry colsep="0" rowsep="1" valign="bottom" id="t5480h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5480h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5480h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5481h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5481h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5481h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5481h1">General arrangement of the installation of the steam boiler in the ship showing means of support.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5481h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5481h1">Design working pressure, temperature and evaporation rate.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5481h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5481h1">Heating surface area of the steam boiler, and where fitted, of the superheater and economizer.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5481h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5481h1">Materials, sizes and arrangement of parts under pressure, including superheaters, economizers and valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5481h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5481h1">Details of welded seams, openings, connections, attachments and supports, including details of welding materials, methods and procedures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5481h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5481h1">Details of the heat treatment process and testing procedures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5481h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5481h1">Pressure setting, relieving capacity and venting arrangements of safety valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5481h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5481h1">Arrangements and details of steam boiler feed-water controls, monitors and alarms, including emergency controls.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5481h0">9.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5481h1">Materials, components, sizes and arrangements of fuel combustion systems, including fuel supply, combustion air supply, air preheaters, exhaust uptakes and combustion controls, monitors and alarms, including emergency controls.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5482h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5482h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5482h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5482h1">Identification from material test certificates, before construction is commenced, of materials to be used, including welding metal, and of physical properties and mechanical test results obtained from material testing carried out in accordance with these Regulations.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5482h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5482h1">Verification that welding was carried out by welders certified by a Provincial Government of Canada, or another authority having similar standards where the welding was carried out outside Canada, for the class of work to be done.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5482h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5482h1">Inspection of welds including non-destructive test examination and verification of the heat treatment process in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5482h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5482h1">Verification of plate preparation and alignment prior to assembly and, on completion of all construction operations, confirmation of circularity of shells.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5482h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5482h1">Identification from the component inspection certificates of components related to the safety of the boiler.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5482h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5482h1">Inspection of components and their installation, including tubes and tube plates.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5482h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5482h1">Inspection of the constructed steam boiler.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5482h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5482h1">Witnessing of hydrostatic pressure tests in accordance with rules or codes.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Installation Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.34*" htmlwidth="10%" /><colspec colname="2" colwidth="89.66*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5483h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5483h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5483h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5483h1">Verification of correct alignment of securing arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5483h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5483h1">Verification of correct adjustment and operational condition of the connection of the steam boiler to steam, feed-water, blowdown and surface blow systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5483h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5483h1">Verification of correct adjustment and operational condition of fuel, combustion air supply and exhaust gas systems, including burners, air fans and air preheaters.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5483h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5483h1">Verification of correct adjustment and operational condition of safety, control and monitoring devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5483h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5483h1">Inspection of safety valve relieving capacity in respect of the maximum evaporation capacity of the steam boiler.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5483h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5483h1">Witnessing of hydrostatic pressure tests at the assigned working pressure.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5483h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5483h1">Verification of reliability and sufficiency under trials up to full power under normal working conditions for a suitable endurance period of not less than 2 hours, taking into consideration the size and complexity of the steam boiler.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5484h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5484h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5484h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5484h1">Correct adjustment and operational condition of safety valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5484h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5484h1">Correct adjustment and operational condition of water gauges and steam boiler valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5484h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5484h1">Locations where fluid leakage, metal overheating or metal wastage may occur.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5484h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5484h1">Correct adjustment and operational condition of emergency fuel shut-off valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5484h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5484h1">Correct adjustment of controls and monitoring systems of feed-water and fuel and its combustion.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5484h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5484h1">Operational condition of alarm systems, particularly where the boiler is designed for non-continuous local supervision.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic Special Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5485h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5485h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5485h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5485h1">Internal steam and liquid spaces, as far as practicable, of the boiler, superheater and economizer, with all spaces cleaned and removable components removed and where, due to construction features, an adequate internal inspection cannot be carried out, a hydrostatic pressure test of 1.25 times the assigned working pressure of the boiler.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5485h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5485h1">Access and inspection openings.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5485h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5485h1">Boiler mountings, including safety valves and water-level gauges, following opening up and cleaning.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5485h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5485h1">Float chambers and float mechanisms on feed-water regulators, following opening up and cleaning.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5485h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5485h1">Pipes, actuators and other components, incorporated in self regulating and monitoring systems, as far as practicable, without dismantling if the general condition of the component shows that it is suitable for further service.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5485h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5485h1">Emergency fuel shut-off devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5485h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5485h1">Combustion spaces following cleaning, excluding uptakes and air preheaters unless there is apparent damage, improper operation or deteriorated condition of the uptakes or air preheaters.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5485h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5485h1">Seams, mountings, seatings, rolling stays, collision chocks and welded attachments, following the removal of insulation and sheathing to the extent considered necessary by the inspector on the basis of the general condition of the boiler.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5485h0">9.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5485h1">Plate thickness testing or hydrostatic pressure testing or other non-destructive testing, if there is apparent damage, improper operation or deteriorated condition of the boiler.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5486h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5486h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5486h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5486h1">Combustion air fans and driving components, at intervals not exceeding 5 years and all other components, at intervals not exceeding 24 months.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;2&quot;"><ScheduleFormHeading><Label>SCHEDULE II</Label><TitleText>LOW-PRESSURE STEAM BOILERS HAVING A DESIGN WORKING PRESSURE NOT EXCEEDING 350 kPa AND HOT-WATER BOILERS HAVING A DESIGN WORKING PRESSURE NOT EXCEEDING 1 100 kPa OR A DESIGN TEMPERATURE NOT EXCEEDING 120°C</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="right" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" align="left" valign="bottom" id="t5487h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5487h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5487h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5487h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="0.85*" align="right" htmlwidth="11%" /><colspec colname="COLSPEC22" colwidth="0.55*" htmlwidth="7%" /><colspec colname="COLSPEC21" colwidth="6.69*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" align="left" valign="bottom" id="t5488h0">Item</entry><entry namest="COLSPEC22" nameend="COLSPEC21" colsep="0" rowsep="1" valign="bottom" id="t5488h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5488h0">1.</entry><entry namest="COLSPEC22" nameend="COLSPEC21" colsep="0" rowsep="0" headers="t5488h1">General arrangement of the installation of the boiler in the ship, showing means of support.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5488h0">2.</entry><entry namest="COLSPEC22" nameend="COLSPEC21" colsep="0" rowsep="0" headers="t5488h1">Design working pressure, temperature and evaporation rate for steam or flow rate for water.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5488h0">3.</entry><entry namest="COLSPEC22" nameend="COLSPEC21" colsep="0" rowsep="0" headers="t5488h1">Heating surface area of the boiler.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5488h0">4.</entry><entry namest="COLSPEC22" nameend="COLSPEC21" colsep="0" rowsep="0" headers="t5488h1">Materials, sizes and arrangements of parts under pressure, including valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5488h0">5.</entry><entry namest="COLSPEC22" nameend="COLSPEC21" colsep="0" rowsep="0" headers="t5488h1">Details of welded seams, openings, connections, attachments and supports, including details of welding materials, methods and procedures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5488h0">6.</entry><entry namest="COLSPEC22" nameend="COLSPEC21" colsep="0" rowsep="0" headers="t5488h1">Pressure setting, relieving capacity and venting arrangement of safety valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5488h0">7.</entry><entry namest="COLSPEC22" nameend="COLSPEC21" colsep="0" rowsep="0" headers="t5488h1">Arrangements and details of boiler feed-water controls, monitors and alarms, including emergency controls.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5488h0">8.</entry><entry namest="COLSPEC22" nameend="COLSPEC21" colsep="0" rowsep="0" headers="t5488h1">Diagrammatic arrangements of fuel supply, combustion air supply, combustion controls, monitors and alarms, including emergency controls and a written description of the combustion controls.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5488h0">9.</entry><entry namest="COLSPEC22" nameend="COLSPEC21" colsep="0" rowsep="0" headers="t5488h1">Where a manufacturer of a boiler certifies that the boiler was constructed in accordance with rules or codes, information set out in items 2 to 7 is not required to be submitted</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5488h0"></entry><entry colsep="0" rowsep="0" headers="t5488h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5488h1">where the boiler is a steam boiler if the design working pressure of the boiler does not exceed 103 kPa; and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5488h0"></entry><entry colsep="0" rowsep="0" headers="t5488h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5488h1">where the boiler is a hot-water boiler if the design working pressure of the boiler does not exceed 210 kPa and the temperature of the hot water in the boiler will not exceed 98°C.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="right" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" align="left" valign="bottom" id="t5489h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5489h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5489h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5489h1">Identification from material test certificates, before construction is commenced, of materials to be used, including welding metal, and of physical properties and mechanical test results obtained from material testing carried out in accordance with these Regulations.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5489h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5489h1">Verification that welding was carried out by welders certified by a Provincial Government of Canada, or another authority having similar standards where the welding was carried out outside Canada, for the class of work to be done.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5489h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5489h1">Inspection of welds, including non-destructive test examination and verification of the heat treatment process in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5489h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5489h1">Verification of plate preparation and alignment prior to assembly and, on completion of all construction operations, confirmation of circularity of shells of the low-pressure steam boiler or of the hot-water boiler.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5489h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5489h1">Identification from the component inspection certificates of components related to the safety of the low-pressure boiler.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5489h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5489h1">Inspection of components and their installation, including tubes and tube plates.</entry></row><row><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5489h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5489h1">Inspection of the constructed low-pressure boiler.</entry></row><row topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="0" align="left" valign="top" headers="t5489h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5489h1">Witnessing of an hydrostatic pressure test in accordance with rules or codes.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Installation Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5490h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5490h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5490h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5490h1">Verification of correct alignment of securing arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5490h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5490h1">Verification of correct adjustment and operational condition of the connection of the boiler to associated systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5490h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5490h1">Verification of correct adjustment and operational condition of safety, control and monitoring devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5490h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5490h1">Witnessing of hydrostatic pressure tests at the assigned working pressure.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5490h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5490h1">Verification of reliability and sufficiency under trials up to full power under normal working conditions for a suitable endurance period of not less than 2 hours, taking into consideration the size and complexity of the boiler.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5491h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5491h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5491h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5491h1">Correct adjustment and operational condition of safety valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5491h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5491h1">Operational condition of water gauges and boiler valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5491h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5491h1">Locations where fluid leakage, metal overheating or metal wastage may occur.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5491h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5491h1">Correct adjustment and operational condition of emergency fuel shut-off valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5491h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5491h1">Correct adjustment of controls and monitoring systems of feed-water and fuel and its combustion.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5491h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5491h1">Operational condition of alarm systems, particularly where the boiler is designed for non-continuous local supervision.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic Special Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="19.80*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC1" colwidth="13.10*" htmlwidth="7%" /><colspec colname="2" colwidth="156.75*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5492h0">Item</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5492h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5492h0">1.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5492h1">Internal steam and liquid spaces, as far as practicable, with all spaces cleaned and removable components removed and where, due to construction features, an adequate internal inspection cannot be carried out, a hydrostatic pressure test of 1.25 times the assigned working pressure of the boiler.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5492h0">2.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5492h1">Access and inspection openings.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5492h0">3.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5492h1">Boiler mountings, including safety valves and water-level gauges, following opening up and cleaning.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5492h0">4.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5492h1">Float chambers and float mechanisms on feed-water regulators, following opening up and cleaning.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5492h0">5.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5492h1">Pipes, actuators and other components, incorporated in self-regulating and monitoring systems, as far as practicable, without dismantling, where the general condition of the pipes, actuators and other components is adequate for further use.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5492h0">6.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5492h1">Emergency fuel shut-off devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5492h0">7.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5492h1">Combustion spaces following cleaning, excluding uptakes unless there is apparent damage, improper operation or deteriorated condition of the uptakes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5492h0">8.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5492h1">Seams, mountings, seatings and welded attachments, following the removal of insulation and sheathing to the extent considered necessary by the inspector on the basis of the general condition of the boiler.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5492h0">9.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5492h1">Plate thickness testing or hydrostatic pressure testing or other non-destructive testing, if there is apparent damage, improper operation or deteriorated condition of the boiler.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5492h0">10.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5492h1">Except where, on the basis of the periodic general inspection, there is apparent damage, improper operation or deteriorated condition of components, items 1 to 9 do not apply to</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5492h0"></entry><entry colsep="0" rowsep="0" headers="t5492h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5492h1">a steam boiler, the design working pressure of which does not exceed 103 kPa; and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5492h0"></entry><entry colsep="0" rowsep="0" headers="t5492h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5492h1">a hot-water boiler, the design working pressure of which does not exceed 210 kPa pressure and temperature of the hot water does not exceed 98°C.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5493h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5493h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5493h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5493h1">At intervals not exceeding 24 months.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;3&quot;"><ScheduleFormHeading><Label>SCHEDULE III</Label><TitleText>UNFIRED PRESSURE VESSELS</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="11.90*" align="left" htmlwidth="12%" /><colspec colname="2" colwidth="88.10*" htmlwidth="88%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5494h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5494h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5494h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5494h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.86*" align="left" htmlwidth="11%" /><colspec colname="COLSPEC2" colwidth="7.32*" htmlwidth="7%" /><colspec colname="2" colwidth="92.74*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5495h0">Item</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5495h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0">1.</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5495h1">General arrangement of the installation of the unfired pressure vessel in the ship, showing means of support.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0">2.</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5495h1">Design working pressure, temperature, volume and nature of fluid under pressure.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0">3.</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5495h1">Materials, sizes and arrangement of parts under pressure, including valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0">4.</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5495h1">Details of welded seams, openings, connections, attachments and supports, including details of welding materials, methods and procedures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0">5.</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5495h1">Details of the heat treatment process and testing procedures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0">6.</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5495h1">Diagrammatic arrangement and a written description of the pressure source and heat exchange, as applicable, including cut-offs and alarms.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0">7.</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5495h1">Pressure setting, relieving capacity and venting arrangements of safety or liquid relief valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0">8.</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5495h1">Details of fusible plugs or similar devices required to protect vessels from over-pressure caused by fire or other heat hazards.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0">9.</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5495h1">Where a manufacturer of an unfired pressure vessel or a hydro-pneumatic tank certifies that the unfired pressure vessel or hydro-pneumatic tank was constructed in accordance with rules or codes, information set out in items 2 to 8 is not required to be submitted for</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0"></entry><entry colsep="0" rowsep="0" headers="t5495h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5495h1">the unfired pressure vessel if it contains only non-flammable liquid with a design working pressure not exceeding 700 kPa and a temperature not exceeding 98°C;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0"></entry><entry colsep="0" rowsep="0" headers="t5495h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5495h1">the hydro-pneumatic tank if the tank has a design working pressure not exceeding 700 kPa and a temperature not exceeding 98°C, except sprinkler and foam tanks for use in fire-fighting;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0"></entry><entry colsep="0" rowsep="0" headers="t5495h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5495h1">the unfired pressure vessel has a design working pressure not exceeding 103 kPa;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0"></entry><entry colsep="0" rowsep="0" headers="t5495h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5495h1">the unfired pressure vessel has a volume under pressure not exceeding 150 L and a design working pressure not exceeding 700 kPa;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0"></entry><entry colsep="0" rowsep="0" headers="t5495h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5495h1">the unfired pressure vessel has an internal volume not exceeding 45 L that has no limit on pressure;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0"></entry><entry colsep="0" rowsep="0" headers="t5495h1">(<Emphasis style="italic">f</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5495h1">the unfired pressure vessel has an internal diameter not exceeding 150 mm that has no limit on pressure; or</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5495h0"></entry><entry colsep="0" rowsep="0" headers="t5495h1">(<Emphasis style="italic">g</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5495h1">the unfired pressure vessel is a component in a refrigerating gas system in which the compressor does not absorb power in excess of 10 kW.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5496h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5496h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5496h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5496h1">Identification from material test certificates, before construction is commenced, of materials to be used, including welding metal, and of physical properties and mechanical test results obtained from material testing carried out in accordance with these Regulations.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5496h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5496h1">Verification that welding was carried out by welders certified by a Provincial Government of Canada, or another authority having similar standards where the welding was carried out outside Canada, for the class of work to be done.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5496h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5496h1">Inspection of welds including non-destructive test examination and verification of the heat treatment process in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5496h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5496h1">Verification of plate preparation and alignment prior to assembly and, on completion of all construction operations, confirmation of circularity of shells.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5496h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5496h1">Identification from component inspection certificates of components related to the safety of the unfired pressure vessel.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5496h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5496h1">Inspection of components and their installation, including tubes and tube plates.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5496h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5496h1">Inspection of the constructed unfired pressure vessel.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5496h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5496h1">Witnessing of hydrostatic pressure tests in accordance with rules or codes.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Installation Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5497h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5497h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5497h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5497h1">Verification of correct alignment of securing arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5497h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5497h1">Verification of correct adjustment and operational condition of the connection of the unfired pressure vessel to associated systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5497h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5497h1">Verification of correct adjustment and operational condition of safety, control and monitoring devices.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5497h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5497h1">Verification of reliability and sufficiency under trials up to the assigned working pressure under normal working conditions for a suitable endurance period, taking into consideration the size and complexity of the unfired pressure vessel and its pressure source.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.34*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.66*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5498h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5498h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5498h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5498h1">Correct adjustment and operational condition of safety devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5498h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5498h1">Operational condition of liquid gauges and attached valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5498h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5498h1">Locations where fluid leakage, metal wastage or metal deformation may occur.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5498h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5498h1">Correct adjustment of controls and monitoring systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5498h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5498h1">Operational condition of alarm systems, particularly where the unfired pressure vessel is designed for non-continuous local supervision.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic Special Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="19.60*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC3" colwidth="13.67*" htmlwidth="7%" /><colspec colname="COLSPEC4" colwidth="14.70*" htmlwidth="8%" /><colspec colname="2" colwidth="146.39*" htmlwidth="75%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5499h0">Item</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5499h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5499h0">1.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5499h1">Internal fluid spaces as far as practicable with all spaces clean and removable components removed and where, due to construction features, an adequate internal inspection cannot be carried out, a hydrostatic pressure test of 1.25 times the assigned working pressure of the spaces.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5499h0">2.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5499h1">Access and inspection openings and fusible plugs where fitted.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5499h0">3.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5499h1">Pressure-vessel mountings, including safety valves and liquid-level gauges, without opening up and cleaning unless there is apparent damage, improper operation or deteriorated condition of those components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5499h0">4.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5499h1">Float chambers and float mechanisms on liquid-level regulators, following opening up and cleaning.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5499h0">5.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5499h1">Pipes, actuators and other components, incorporated in self-regulating and monitoring systems, as far as is practicable, without dismantling where their general condition shows that they are suitable for further service.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5499h0">6.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5499h1">Seams, mountings, seatings and welded attachments, following the removal of insulation and sheathing, to the extent considered necessary by the inspector, on the basis of the general condition of the unfired pressure vessel.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5499h0">7.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5499h1">Except where, on the basis of the periodic general inspection, there is apparent damage, improper operation or deteriorated condition of components, items 1 to 6 do not apply where</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5499h0"></entry><entry colsep="0" rowsep="0" headers="t5499h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5499h1">the assigned working pressure does not exceed 103 kPa;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5499h0"></entry><entry colsep="0" rowsep="0" headers="t5499h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5499h1">the internal diameter does not exceed 150 mm;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5499h0"></entry><entry colsep="0" rowsep="0" headers="t5499h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5499h1">the volume or part thereof above the normal working level of a liquid does not exceed</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5499h0"></entry><entry colsep="0" rowsep="0" headers="t5499h1"></entry><entry colsep="0" rowsep="0" headers="t5499h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5499h1">45 L, or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5499h0"></entry><entry colsep="0" rowsep="0" headers="t5499h1"></entry><entry colsep="0" rowsep="0" headers="t5499h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5499h1">150 L when the assigned working pressure does not exceed 700 kPa; or</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5499h0"></entry><entry colsep="0" rowsep="0" headers="t5499h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5499h1">the unfired pressure vessel is a component in a refrigerating gas system in which the gas compressor does not absorb power in excess of 10 kW.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5500h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5500h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5500h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5500h1">Steam-heated steam generators, at intervals not exceeding 2 years.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5500h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5500h1">Water evaporators and steam condensers, at intervals not exceeding 5 years.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5500h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5500h1">Unfired pressure vessels containing air or air and water under pressure, at intervals not exceeding 5 years.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5500h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5500h1">Unfired pressure vessels containing non-corrosive liquid or non-corrosive liquid and gas under pressure, at intervals not exceeding 20 years.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5500h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5500h1">Liquid tubular heat exchangers with one fluid side opened up, at intervals not exceeding 5 years, and without further dismantling unless dismantling is considered necessary by the inspector on the basis of the general condition of the heat exchangers.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;4&quot;"><ScheduleFormHeading><Label>SCHEDULE IV</Label><TitleText>RECIPROCATING ENGINES</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Internal Combustion Oil Engines</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5501h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5501h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5501h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5501h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Steam Reciprocating Engines</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5502h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5502h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5502h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5502h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Internal Combustion Oil Engines</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="21.62*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC6" colwidth="14.43*" htmlwidth="7%" /><colspec colname="2" colwidth="18.65*" htmlwidth="9%" /><colspec colname="COLSPEC5" colwidth="154.36*" htmlwidth="74%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5503h0">Item</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="1" valign="bottom" id="t5503h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">1.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">General arrangement of the installation of the engine in the ship, showing all connected systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">2.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">General arrangement and sectional elevation of the engine, including crankcase doors and means of engine support.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">3.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">Specifications indicating maximum continuous brake power and corresponding revolutions per minute, number of strokes per cycle, number and firing order of cylinders, bore and stroke dimensions, maximum and mean indicated pressures, full details of balance weights, full details of flywheel and physical properties of the principal parts.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">4.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">Details of pressure charging, scavenging and exhaust arrangements including mechanisms, piping and pipe connections, type and amount of insulation and method of securing to allow for thermal expansion and vibration.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">5.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">Details of all cylinders, cylinder covers, pistons, piston rods, connecting rods and bearings and of the crankshaft and bedplate.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">6.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">Details of the fuel injection system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">7.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">Details of lubricating-oil, cooling-water and other attached pumping systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">8.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">Details of starting arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">9.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">Details of controls including reversing arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">10.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">Details of speed-regulating governors and other safety devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">11.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">Details of temperature-monitoring devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">12.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">Details of crankcase venting, crankcase explosion relief valves and other protection devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">13.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">Details of engine turning gear.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">14.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">Torsional vibration analysis of shafting system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0">15.</entry><entry namest="COLSPEC6" nameend="COLSPEC5" colsep="0" rowsep="0" headers="t5503h1">Information set out in items 2 to 14 is not required to be submitted for the following internal combustion oil engines, namely, an engine</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0"></entry><entry colsep="0" rowsep="0" headers="t5503h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="2" nameend="COLSPEC5" colsep="0" rowsep="0" valign="top" headers="t5503h1">with a continuous brake power not in excess of 112 kW;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0"></entry><entry colsep="0" rowsep="0" headers="t5503h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="2" nameend="COLSPEC5" colsep="0" rowsep="0" valign="top" headers="t5503h1">with a continuous brake power in excess of 112 kW but not in excess of 375 kW, where the manufacturer submits the following documented information, namely,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0"></entry><entry colsep="0" rowsep="0" headers="t5503h1"></entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5503h1">(i)</entry><entry colsep="0" rowsep="0" headers="t5503h1">model and serial number and type of engine,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0"></entry><entry colsep="0" rowsep="0" headers="t5503h1"></entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5503h1">(ii)</entry><entry colsep="0" rowsep="0" headers="t5503h1">number of cylinders, bore and stroke dimensions,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0"></entry><entry colsep="0" rowsep="0" headers="t5503h1"></entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5503h1">(iii)</entry><entry colsep="0" rowsep="0" headers="t5503h1">maximum continuous brake power and the corresponding revolutions per minute,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0"></entry><entry colsep="0" rowsep="0" headers="t5503h1"></entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5503h1">(iv)</entry><entry colsep="0" rowsep="0" headers="t5503h1">volume of the engine crankcase and full details of crankcase explosion relief valves, where the cylinder bore is in excess of 200 mm,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0"></entry><entry colsep="0" rowsep="0" headers="t5503h1"></entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5503h1">(v)</entry><entry colsep="0" rowsep="0" headers="t5503h1">name of the manufacturer and model of the speed-regulating governor,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0"></entry><entry colsep="0" rowsep="0" headers="t5503h1"></entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5503h1">(vi)</entry><entry colsep="0" rowsep="0" headers="t5503h1">relieving pressure and capacity of cylinder-head relief valves, and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0"></entry><entry colsep="0" rowsep="0" headers="t5503h1"></entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5503h1">(vii)</entry><entry colsep="0" rowsep="0" headers="t5503h1">test data up to full power taken from a representative engine of the same model;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0"></entry><entry colsep="0" rowsep="0" headers="t5503h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="2" nameend="COLSPEC5" colsep="0" rowsep="0" valign="top" headers="t5503h1">that is a portable equipment prime mover, unless of unusual design; or</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5503h0"></entry><entry colsep="0" rowsep="0" headers="t5503h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="2" nameend="COLSPEC5" colsep="0" rowsep="0" valign="top" headers="t5503h1">that is a lifeboat engine that meets the requirements of the <XRefExternal reference-type="regulation">Lifesaving Equipment Regulations</XRefExternal>.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Steam Reciprocating Engines</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="top" id="t5504h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="top" id="t5504h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5504h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5504h1">General arrangement of the installation of the engine in the ship, showing all connected systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5504h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5504h1">General arrangement and sectional elevation of the engine and means of support.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5504h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5504h1">Specifications showing the indicated power and corresponding revolutions per minute, number of cylinders, bore and stroke dimensions, maximum pressure per cylinder, full details of flywheel and physical properties of principal parts.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5504h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5504h1">Details of all cylinders, cylinder covers, pistons, piston rods, connecting rods and bearings and of the crankshaft and bedplate.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5504h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5504h1">Details of lubricating oil systems and other attached pumping systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5504h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5504h1">Details of controls, including reversing arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5504h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5504h1">Details of speed-regulating governors and other safety devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5504h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5504h1">Details of crankcase venting.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5504h0">9.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5504h1">Details of engine turning gear.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5504h0">10.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5504h1">Where a manufacturer of a steam reciprocating engine certifies that the engine was constructed in accordance with rules or codes, information set out in items 2 to 9 is not required to be submitted for the steam reciprocating engine if it is not in excess of 375 kW continuous brake power.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.67*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC7" colwidth="7.51*" htmlwidth="7%" /><colspec colname="2" colwidth="92.74*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5505h0">Item</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5505h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5505h0">1.</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="0" headers="t5505h1">Identification from material test certificates, before construction is commenced, of materials to be used, including welding metal, for the following parts:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5505h0"></entry><entry colsep="0" rowsep="0" headers="t5505h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5505h1">crankshafts, bearings and bolts;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5505h0"></entry><entry colsep="0" rowsep="0" headers="t5505h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5505h1">pistons, piston rods, connecting rods, guides, crossheads, bearings and bolts;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5505h0"></entry><entry colsep="0" rowsep="0" headers="t5505h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5505h1">cylinders, cylinder liners, covers, valves, valve mechanisms, pillars and bolts;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5505h0"></entry><entry colsep="0" rowsep="0" headers="t5505h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5505h1">bedplates and frames; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5505h0"></entry><entry colsep="0" rowsep="0" headers="t5505h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5505h1">pressure charging and scavenging mechanisms for internal combustion oil engines.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5505h0">2.</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="0" headers="t5505h1">Verification that welding was carried out by welders certified by a Provincial Government of Canada, or another authority having similar standards where the welding was carried out outside Canada, for the class of work to be done.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5505h0">3.</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="0" headers="t5505h1">Inspection of welds including non-destructive test examination and verification of any heat treatment required in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5505h0">4.</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="0" headers="t5505h1">Identification of components from component inspection certificates and inspection of components and their installation, including engine-driven pumps.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5505h0">5.</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="0" headers="t5505h1">Witnessing of hydrostatic pressure tests of components in accordance with rules or codes.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5505h0">6.</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="0" headers="t5505h1">Inspection of the constructed engine and witnessing of the engine under test.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Installation Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5506h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5506h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5506h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5506h1">Verification of correct alignment of securing arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5506h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5506h1">Verification of correct adjustment and operational condition of the connection of the engine to associated systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5506h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5506h1">Verification of correct adjustment and operational condition of safety, control and monitoring devices.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5506h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5506h1">Verification of reliability and sufficiency under trials up to full power under normal working conditions for a suitable endurance period of not less than 2 hours, taking into consideration the size and the complexity of the steam reciprocating engine or the internal combustion oil engine.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5507h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5507h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5507h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5507h1">Operational condition of the engine.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5507h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5507h1">Correct adjustment and operational condition of safety devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5507h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5507h1">Locations where fluid leakage, metal wastage, overheating, heavy vibration or excessive bearing clearances may occur.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5507h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5507h1">Correct adjustment of controls and monitoring systems.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5507h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5507h1">Operational condition of alarm systems.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic Special Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5508h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5508h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5508h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5508h1">Crankcase, crankshaft, bearings and bolts.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5508h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5508h1">Pistons, piston rods, connecting rods, guides, cross-heads, bearings and bolts except that removal of thrust bearing components that are an integral part of an engine is not required if tolerances meet the manufacturer’s specifications and there is no apparent damage or deterioration.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5508h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5508h1">Cylinders, covers, valves, and valve mechanisms.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5508h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5508h1">Crankcase doors, explosion relief devices and other safety devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5508h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5508h1">Crankcase venting arrangement.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5508h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5508h1">Pressure charging, scavenging and exhaust systems for internal combustion oil engines.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5508h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5508h1">Attached pumps.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5508h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5508h1">Starting mechanisms and clutch gears for internal combustion oil engines.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5508h0">9.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5508h1">Reversing and speed-regulating mechanisms.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5508h0">10.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5508h1">Bedplate, engine structure and fastenings, without dismantling if a general examination indicates that the condition of the components is adequate for further service.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5508h0">11.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5508h1">No periodic special inspection is required for speed-regulating governors and other complex mechanisms, where written information is provided to the inspector by firms specializing in the reconditioning of these parts indicating that the parts are in good order and adjustment.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5508h0">12.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5508h1">For an internal combustion engine not in excess of 450 kW continuous brake power, the removal of pistons and dismantling of bearings is not required if examination of the cylinder cover and crankcase indicates that the condition of the engine is adequate for further service.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.37*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC8" colwidth="7.70*" htmlwidth="7%" /><colspec colname="2" colwidth="91.51*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5509h0">Item</entry><entry namest="COLSPEC8" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5509h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5509h0">1.</entry><entry namest="COLSPEC8" nameend="2" colsep="0" rowsep="0" headers="t5509h1">For steam reciprocating engines, at intervals not exceeding 5 years.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5509h0">2.</entry><entry namest="COLSPEC8" nameend="2" colsep="0" rowsep="0" headers="t5509h1">Subject to item 3, for internal combustion oil engines, at intervals of not more than 5 years.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5509h0">3.</entry><entry namest="COLSPEC8" nameend="2" colsep="0" rowsep="0" headers="t5509h1">For internal combustion oil engines on the following ships, namely,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5509h0"></entry><entry colsep="0" rowsep="0" headers="t5509h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5509h1">passenger ships on voyages not beyond Home Trade Class IV and Minor Waters Class I;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5509h0"></entry><entry colsep="0" rowsep="0" headers="t5509h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5509h1">multi-engined passenger ships, on voyages not beyond Home Trade Class III or Inland Waters Class I;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5509h0"></entry><entry colsep="0" rowsep="0" headers="t5509h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5509h1">non-passenger ships, excluding tankers, chemical carriers and liquefied gas carriers, on voyages not beyond Home Trade Class II;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5509h0"></entry><entry colsep="0" rowsep="0" headers="t5509h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5509h1">tankers, chemical carriers and liquefied gas carriers on voyages not beyond Home Trade Class IV and Minor Waters Class I; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5509h0"></entry><entry colsep="0" rowsep="0" headers="t5509h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5509h1">multi-engined tankers, chemical carriers and liquefied gas carriers, on voyages not beyond Home Trade Class III or Inland Waters Class I,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5509h0"></entry><entry namest="COLSPEC8" nameend="2" colsep="0" rowsep="0" headers="t5509h1">after completion of the manufacturer’s recommended running hours but at intervals of not less than 5 years, on the basis of documentary evidence presented to the inspector, or at intervals of 8 years, whichever comes first, if, where the periodic general inspection is carried out annually, at the fifth and subsequent periodic general inspections the engine is in good order based on</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5509h0"></entry><entry colsep="0" rowsep="0" headers="t5509h1">(<Emphasis style="italic">f</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5509h1">engine operation;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5509h0"></entry><entry colsep="0" rowsep="0" headers="t5509h1">(<Emphasis style="italic">g</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5509h1">engine operation records indicating total engine running hours, lubricating oil analysis and maintenance work carried out; and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5509h0"></entry><entry colsep="0" rowsep="0" headers="t5509h1">(<Emphasis style="italic">h</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5509h1">a crankcase inspection where considered necessary by the inspector.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;5&quot;"><ScheduleFormHeading><Label>SCHEDULE V</Label><TitleText>TURBINE ENGINES</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Steam Turbine Engines</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.34*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.66*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5510h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5510h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5510h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5510h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Gas Turbine Engines</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5511h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5511h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5511h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5511h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Steam Turbine Engines</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.24*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.76*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5512h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5512h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5512h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5512h1">General arrangement of the installation of the engine in the ship, showing all connected systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5512h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5512h1">General arrangement and sectional elevation of the engine and means of support.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5512h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5512h1">Specifications for ahead and astern turbines indicating maximum continuous brake power and corresponding revolutions per minute, steam pressures and temperatures at turbine inlet and exhaust, full details of cylinders, rotors, nozzles, blades, couplings and clutches, full details of physical properties of principal parts, details of forgings, castings and weldments, details of the heat treatment process and testing procedures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5512h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5512h1">Details of bearings and lubricating oil systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5512h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5512h1">Details of controls including reversing arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5512h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5512h1">Details of speed-regulating governors, lubricating oil failure-protection arrangements and other safety devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5512h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5512h1">Details of engine turning gear.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5512h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5512h1">Details of critical speeds of rotating assemblies including vibration analyses.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Gas Turbine Engines</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.55*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC9" colwidth="7.51*" htmlwidth="7%" /><colspec colname="2" colwidth="92.86*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5513h0">Item</entry><entry namest="COLSPEC9" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5513h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0">1.</entry><entry namest="COLSPEC9" nameend="2" colsep="0" rowsep="0" headers="t5513h1">General arrangement of the installation of the engine in the ship, showing all connected systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0">2.</entry><entry namest="COLSPEC9" nameend="2" colsep="0" rowsep="0" headers="t5513h1">General arrangement and sectional elevation of the engine and means of support.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0">3.</entry><entry namest="COLSPEC9" nameend="2" colsep="0" rowsep="0" headers="t5513h1">Specifications of the turbine and compressor indicating maximum continuous brake power and corresponding revolutions per minute, gas pressures and temperatures, full details of casings, combustion chambers, rotors, nozzles, blades, heat exchangers, couplings and clutches, full details of physical properties of principal parts, details of forgings, castings and weldments, details of the heat treatment process and testing procedures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0">4.</entry><entry namest="COLSPEC9" nameend="2" colsep="0" rowsep="0" headers="t5513h1">Details of fuel system including fuel oil viscosities required for starting and running.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0">5.</entry><entry namest="COLSPEC9" nameend="2" colsep="0" rowsep="0" headers="t5513h1">Details of air inlet and exhaust arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0">6.</entry><entry namest="COLSPEC9" nameend="2" colsep="0" rowsep="0" headers="t5513h1">Details of controls including means of starting and of fuel ignition.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0">7.</entry><entry namest="COLSPEC9" nameend="2" colsep="0" rowsep="0" headers="t5513h1">Details of bearings and of lubricating oil systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0">8.</entry><entry namest="COLSPEC9" nameend="2" colsep="0" rowsep="0" headers="t5513h1">Details of speed-regulating governors, lubricating oil failure protection arrangements and other safety devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0">9.</entry><entry namest="COLSPEC9" nameend="2" colsep="0" rowsep="0" headers="t5513h1">Details of engine turning gear.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0">10.</entry><entry namest="COLSPEC9" nameend="2" colsep="0" rowsep="0" headers="t5513h1">Details of critical speeds of rotating assemblies including vibration analyses.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0">11.</entry><entry namest="COLSPEC9" nameend="2" colsep="0" rowsep="0" headers="t5513h1">Information set out in items 1 to 10 is not required to be submitted for</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0"></entry><entry colsep="0" rowsep="0" headers="t5513h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5513h1">gas turbine engines not in excess of 375 kW continuous brake power;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0"></entry><entry colsep="0" rowsep="0" headers="t5513h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5513h1">portable gas turbine engines; or</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5513h0"></entry><entry colsep="0" rowsep="0" headers="t5513h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5513h1">gas turbine engines driven by exhaust gases from a reciprocating-type internal combustion oil engine, except that information respecting a gas turbine for a reciprocating-type internal combustion oil engine shall be submitted in accordance with Schedule IV.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.66*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC10" colwidth="7.52*" htmlwidth="7%" /><colspec colname="2" colwidth="92.74*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5514h0">Item</entry><entry namest="COLSPEC10" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5514h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5514h0">1.</entry><entry namest="COLSPEC10" nameend="2" colsep="0" rowsep="0" headers="t5514h1">Identification from material test certificates, before construction is commenced, of materials to be used, including welding metal, for the following parts:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5514h0"></entry><entry colsep="0" rowsep="0" headers="t5514h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5514h1">turbine cylinder assembly, including covers, discs, nozzles, blades and bolts;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5514h0"></entry><entry colsep="0" rowsep="0" headers="t5514h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5514h1">turbine rotor assembly including discs, blades and bolts;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5514h0"></entry><entry colsep="0" rowsep="0" headers="t5514h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5514h1">valves, pipes, couplings, clutches, bearings and bolts;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5514h0"></entry><entry colsep="0" rowsep="0" headers="t5514h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5514h1">compressor cylinder and rotor assembly for a gas turbine; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5514h0"></entry><entry colsep="0" rowsep="0" headers="t5514h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5514h1">combustion chamber and heat exchanger for a gas turbine.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5514h0">2.</entry><entry namest="COLSPEC10" nameend="2" colsep="0" rowsep="0" headers="t5514h1">Verification that welding was carried out by welders certified by a Provincial Government of Canada, or another authority having similar standards where the welding was carried out outside Canada, for the class of work to be done.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5514h0">3.</entry><entry namest="COLSPEC10" nameend="2" colsep="0" rowsep="0" headers="t5514h1">Inspection of welds, including non-destructive test examination and verification of any required heat treatment process in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5514h0">4.</entry><entry namest="COLSPEC10" nameend="2" colsep="0" rowsep="0" headers="t5514h1">Verification of rotor balance and thermal stability testing in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5514h0">5.</entry><entry namest="COLSPEC10" nameend="2" colsep="0" rowsep="0" headers="t5514h1">Identification of components from component inspection certificates and inspection of components and their installation.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5514h0">6.</entry><entry namest="COLSPEC10" nameend="2" colsep="0" rowsep="0" headers="t5514h1">Witnessing of hydrostatic pressure tests of components in accordance with rules or codes.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5514h0">7.</entry><entry namest="COLSPEC10" nameend="2" colsep="0" rowsep="0" headers="t5514h1">Inspection of the constructed engine and witnessing of the engine operation under test.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Installation Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5515h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5515h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5515h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5515h1">Verification of correct alignment of securing arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5515h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5515h1">Verification of correct adjustment and operational condition of the connection of the engine to associated systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5515h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5515h1">Verification of correct adjustment and operational condition of safety, control and monitoring devices.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5515h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5515h1">Verification of reliability and sufficiency under trials up to full power under normal working conditions for a suitable endurance period of not less than 2 hours, taking into consideration the size and the complexity of the gas turbine engine or steam turbine engine.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL AND SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5516h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5516h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5516h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5516h1">Operational condition of the engine.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5516h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5516h1">Correct adjustment and operational condition of safety devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5516h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5516h1">Locations where fluid leakage, metal wastage, overheating, heavy vibration or excessive bearing clearance may occur.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5516h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5516h1">Correct adjustment of controls and monitoring systems.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5516h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5516h1">Operational condition of alarm systems, particularly where the engine is designed for non-continuous local supervision.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic Special Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5517h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5517h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5517h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5517h1">Casings, glands, nozzles, blades, valves and valve mechanisms.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5517h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5517h1">Rotors, blades, couplings, thrusts, bearings and bolts.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5517h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5517h1">Speed-regulating governors and other safety devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5517h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5517h1">Attached pumps.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5517h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5517h1">Compressors, combustion chambers, heat exchangers, air inlet, fuel and exhaust, and starting system for a gas turbine engine.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5517h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5517h1">Engine structure and fastenings without dismantling if a general examination shows that the condition of the components is adequate for further service.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5517h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5517h1">No inspection is required for speed-regulating governors and other complex mechanisms where written information is provided to the inspector by firms specializing in the reconditioning of those mechanisms, indicating that the parts are in good order and adjustment.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5518h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5518h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5518h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5518h1">For gas turbine engines and steam turbine engines, at intervals not exceeding 5 years.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5518h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5518h1">Notwithstanding item 1, the first lifting of the casing and rotor of a steam turbine engine that has more than one propulsion ahead turbine with an emergency crossover arrangement is deferred until the engine is 10 years old if the inspector is satisfied that the turbine is in good operating condition based on the records of the vibration indicator, the rotor position indicator and the turbine operation.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;6&quot;"><ScheduleFormHeading><Label>SCHEDULE VI</Label><TitleText>REVERSING AND REDUCTION GEARING, SHAFTING SYSTEMS AND PROPELLERS</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Reversing and Reduction Gearing</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5519h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5519h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5519h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5519h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Shafting Systems</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="12.43*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC16" colwidth="8.42*" htmlwidth="7%" /><colspec colname="COLSPEC17" colwidth="9.05*" htmlwidth="7%" /><colspec colname="2" colwidth="91.25*" htmlwidth="75%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5520h0">Item</entry><entry namest="COLSPEC16" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5520h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5520h0">1.</entry><entry namest="COLSPEC16" nameend="2" colsep="0" rowsep="0" headers="t5520h1">Screw shafts shall be made of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5520h0"></entry><entry colsep="0" rowsep="0" headers="t5520h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC17" nameend="2" colsep="0" rowsep="0" headers="t5520h1">carbon steel protected from exposure to water in the stern bearing by a corrosion-resistant continuous liner, or non-continuous liners between each of which is a welded joint or a suitable bonded coating;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5520h0"></entry><entry colsep="0" rowsep="0" headers="t5520h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC17" nameend="2" colsep="0" rowsep="0" headers="t5520h1">carbon steel protected from exposure to water by means of an oil lubricated stern bearing with internal and external glands;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5520h0"></entry><entry colsep="0" rowsep="0" headers="t5520h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC17" nameend="2" colsep="0" rowsep="0" headers="t5520h1">corrosion resistant metal in accordance with rules or codes; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5520h0"></entry><entry colsep="0" rowsep="0" headers="t5520h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC17" nameend="2" colsep="0" rowsep="0" headers="t5520h1">carbon steel not fitted with the methods of water exposure protection referred to in subitem (<Emphasis style="italic">a</Emphasis>) or (<Emphasis style="italic">b</Emphasis>).</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5520h0">2.</entry><entry namest="COLSPEC16" nameend="2" colsep="0" rowsep="0" headers="t5520h1">The screw shaft shall have the propeller attached by means of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5520h0"></entry><entry colsep="0" rowsep="0" headers="t5520h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC17" nameend="2" colsep="0" rowsep="0" headers="t5520h1">a suitable shaft taper with a keyway that is</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5520h0"></entry><entry colsep="0" rowsep="0" headers="t5520h1"></entry><entry colsep="0" rowsep="0" headers="t5520h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5520h1">in sled runner form, or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5520h0"></entry><entry colsep="0" rowsep="0" headers="t5520h1"></entry><entry colsep="0" rowsep="0" headers="t5520h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5520h1">in a form where the top end is well rounded and smoothed off, with an adequate root radius;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5520h0"></entry><entry colsep="0" rowsep="0" headers="t5520h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC17" nameend="2" colsep="0" rowsep="0" headers="t5520h1">a suitable shaft taper with no keyway; or</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5520h0"></entry><entry colsep="0" rowsep="0" headers="t5520h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC17" nameend="2" colsep="0" rowsep="0" headers="t5520h1">a coupling flange.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division III</Label><TitleText>Propellers</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5521h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5521h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5521h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5521h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Reversing and Reduction Gearing</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="12.30*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC19" colwidth="8.55*" htmlwidth="7%" /><colspec colname="COLSPEC18" colwidth="10.35*" htmlwidth="9%" /><colspec colname="2" colwidth="89.95*" htmlwidth="74%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5522h0">Item</entry><entry namest="COLSPEC19" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5522h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5522h0">1.</entry><entry namest="COLSPEC19" nameend="2" colsep="0" rowsep="0" headers="t5522h1">General arrangement of the installation of the gearing in the ship, showing all connected systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5522h0">2.</entry><entry namest="COLSPEC19" nameend="2" colsep="0" rowsep="0" headers="t5522h1">General arrangement and sectional elevation of the gearing unit, including means of gearcase support.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5522h0">3.</entry><entry namest="COLSPEC19" nameend="2" colsep="0" rowsep="0" headers="t5522h1">Specifications indicating maximum input torque and corresponding revolutions per minute for each pinion, details of pinions and wheels, number of teeth, pitch, form and helix angles, details of wheel-rim attachment, gear-cutting and post-cutting processes, physical properties of principal parts, details of forgings, castings and weldments, details of the heat treatment process and testing procedures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5522h0">4.</entry><entry namest="COLSPEC19" nameend="2" colsep="0" rowsep="0" headers="t5522h1">Details of gearcase, including access openings and venting arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5522h0">5.</entry><entry namest="COLSPEC19" nameend="2" colsep="0" rowsep="0" headers="t5522h1">Details of shafting systems, including couplings, clutches, reversing gear where fitted, and balancing and vibration analyses.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5522h0">6.</entry><entry namest="COLSPEC19" nameend="2" colsep="0" rowsep="0" headers="t5522h1">Details of bearings, lubricating oil systems and temperature monitoring devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5522h0">7.</entry><entry namest="COLSPEC19" nameend="2" colsep="0" rowsep="0" headers="t5522h1">Information set out in items 2 to 6 are not required to be submitted for a gearing system</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5522h0"></entry><entry colsep="0" rowsep="0" headers="t5522h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC18" nameend="2" colsep="0" rowsep="0" headers="t5522h1">not in excess of 225 kW continuous brake power; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5522h0"></entry><entry colsep="0" rowsep="0" headers="t5522h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC18" nameend="2" colsep="0" rowsep="0" headers="t5522h1">over 225 kW and not in excess of 375 kW continuous brake power, where the manufacturer submits the following documented information:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5522h0"></entry><entry colsep="0" rowsep="0" headers="t5522h1"></entry><entry colsep="0" rowsep="0" headers="t5522h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5522h1">model and serial number and type of gearing,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5522h0"></entry><entry colsep="0" rowsep="0" headers="t5522h1"></entry><entry colsep="0" rowsep="0" headers="t5522h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5522h1">maximum continuous input torque and corresponding revolutions per minute,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5522h0"></entry><entry colsep="0" rowsep="0" headers="t5522h1"></entry><entry colsep="0" rowsep="0" headers="t5522h1">(iii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5522h1">gearing reduction, and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5522h0"></entry><entry colsep="0" rowsep="0" headers="t5522h1"></entry><entry colsep="0" rowsep="0" headers="t5522h1">(iv)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5522h1">test data up to full power taken from a representative gearing system of the same model.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Shafting Systems for Propulsion, Electrical Generators and Motors</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.54*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC20" colwidth="7.76*" htmlwidth="7%" /><colspec colname="2" colwidth="92.62*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5523h0">Item</entry><entry namest="COLSPEC20" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5523h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5523h0">1.</entry><entry namest="COLSPEC20" nameend="2" colsep="0" rowsep="0" headers="t5523h1">General arrangement of the propulsion shafting, the electrical generator shafting and motor shafting in the ship, showing all connected systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5523h0">2.</entry><entry namest="COLSPEC20" nameend="2" colsep="0" rowsep="0" headers="t5523h1">General arrangement and sectional elevation of the shafting systems, detailing attachments to driving and driven members and means of support.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5523h0">3.</entry><entry namest="COLSPEC20" nameend="2" colsep="0" rowsep="0" headers="t5523h1">Specifications indicating maximum input power and corresponding revolutions per minute, alignment of shafting system and bearing type and loading, physical properties of materials and testing procedures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5523h0">4.</entry><entry namest="COLSPEC20" nameend="2" colsep="0" rowsep="0" headers="t5523h1">For ship propulsion shafting systems, details of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5523h0"></entry><entry colsep="0" rowsep="0" headers="t5523h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5523h1">intermediate, thrust and screw shafts including liners, in particular protective coating for carbon steel screw shafts with non-continuous liners;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5523h0"></entry><entry colsep="0" rowsep="0" headers="t5523h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5523h1">intermediate, thrust, stern and “A” bracket bearings;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5523h0"></entry><entry colsep="0" rowsep="0" headers="t5523h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5523h1">stern bushes and stern glands including their attachments to the ship;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5523h0"></entry><entry colsep="0" rowsep="0" headers="t5523h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5523h1">shaft lubrication arrangements; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5523h0"></entry><entry colsep="0" rowsep="0" headers="t5523h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5523h1">critical speed of rotating assembly including vibration analysis.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5523h0">5.</entry><entry namest="COLSPEC20" nameend="2" colsep="0" rowsep="0" headers="t5523h1">Information set out in items 2 to 4 is not required to be submitted for shafting systems</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5523h0"></entry><entry colsep="0" rowsep="0" headers="t5523h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5523h1">not in excess of 225 kW continuous brake power on ship propulsion systems; or</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5523h0"></entry><entry colsep="0" rowsep="0" headers="t5523h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5523h1">not in excess of 375 kW continuous brake power in ship service electrical generators and motors.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division III</Label><TitleText>Fixed Pitch, Controllable Pitch and Directional Propellers</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.34*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.66*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5524h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5524h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5524h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5524h1">General arrangement of the propeller, including details of fastening arrangement to the shafting systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5524h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5524h1">Specifications indicating maximum input power and corresponding revolutions per minute, physical properties of materials, stress calculations and testing procedures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5524h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5524h1">Details of hub, hub mechanisms, seals, blade connections, control devices and locations.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5524h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5524h1">Details of blade form and degree of controllability of pitch.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5524h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5524h1">Information set out in items 2 to 4 is not required to be submitted for propellers not in excess of 225 kW continuous brake power.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.55*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC24" colwidth="7.75*" htmlwidth="7%" /><colspec colname="2" colwidth="92.63*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5525h0">Item</entry><entry namest="COLSPEC24" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5525h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5525h0 t5525h1"><Emphasis style="italic">Reversing and Reduction Gearing</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0">1.</entry><entry namest="COLSPEC24" nameend="2" colsep="0" rowsep="0" headers="t5525h1">Identification from material test certificates, before construction is commenced, of materials to be used, including welding metal, for the following parts:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0"></entry><entry colsep="0" rowsep="0" headers="t5525h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5525h1">shafting, pinions, wheels, couplings, clutches, and bolts; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0"></entry><entry colsep="0" rowsep="0" headers="t5525h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5525h1">gearcase, bearings, piping, valves, and bolts.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0">2.</entry><entry namest="COLSPEC24" nameend="2" colsep="0" rowsep="0" headers="t5525h1">Verification that welding was carried out by welders certified by a Provincial Government of Canada, or another authority having similar standards where the welding was carried out outside Canada, for the class of work to be done.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0">3.</entry><entry namest="COLSPEC24" nameend="2" colsep="0" rowsep="0" headers="t5525h1">Inspection of welds, including non-destructive test examination and verification of any required heat treatment process in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0">4.</entry><entry namest="COLSPEC24" nameend="2" colsep="0" rowsep="0" headers="t5525h1">Verification of correct wheel-rim cutting, gear-cutting and post-cutting processes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0">5.</entry><entry namest="COLSPEC24" nameend="2" colsep="0" rowsep="0" headers="t5525h1">Verification of correct balance of rotating components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0">6.</entry><entry namest="COLSPEC24" nameend="2" colsep="0" rowsep="0" headers="t5525h1">Identification of components from component inspection certificates and inspection of components and their installation.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0">7.</entry><entry namest="COLSPEC24" nameend="2" colsep="0" rowsep="0" headers="t5525h1">Inspection of the completed gearcase and witnessing of the gearing operation under test conditions.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5525h0 t5525h1"><Emphasis style="italic">Shafting Systems for Propulsion, Electrical Generators and Motors</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0">8.</entry><entry namest="COLSPEC24" nameend="2" colsep="0" rowsep="0" headers="t5525h1">Identification from material test or component inspection certificates, before construction is commenced, of materials to be used for the following parts:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0"></entry><entry colsep="0" rowsep="0" headers="t5525h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5525h1">electrical generator and motor shafts, ship propulsion intermediate, thrust and screw shafts, including liners and bolts; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0"></entry><entry colsep="0" rowsep="0" headers="t5525h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5525h1">intermediate, thrust, stern and “A” bracket bearings and stern bushes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0">9.</entry><entry namest="COLSPEC24" nameend="2" colsep="0" rowsep="0" headers="t5525h1">Inspection of the constructed components and confirmation of correct liner installation.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5525h0 t5525h1"><Emphasis style="italic">Fixed Pitch, Controllable Pitch and Directional Propellers</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0">10.</entry><entry namest="COLSPEC24" nameend="2" colsep="0" rowsep="0" headers="t5525h1">Identification from material test or component inspection certificates, before construction is commenced, of materials to be used for propellers, nuts, glands, keys, cones and, as applicable, hubs, blades, nuts, pitch and directional control mechanisms.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5525h0">11.</entry><entry namest="COLSPEC24" nameend="2" colsep="0" rowsep="0" headers="t5525h1">Inspection of assembled components, including non-destructive test examination as required by the inspector.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Installation Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.34*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.66*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5526h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5526h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5526h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5526h1">Verification of correct alignment of securing arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5526h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5526h1">Verification of correct adjustment and operational condition the gearing, shafting systems, propellers and their connections to associated systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5526h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5526h1">Verification of correct adjustment and operational condition of safety, control and monitoring devices.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5526h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5526h1">Verification of reliability and sufficiency under trials up to full power capacity under normal working conditions for a suitable endurance period of not less than 2 hours, taking into consideration the size and complexity of the reversing and reduction gearing, shafting systems and propellers.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5527h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5527h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5527h0 t5527h1"><Emphasis style="italic">Reversing and Reduction Gearing</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Operational condition of the gearing system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Operational condition of the reversing system in reversing and reduction gearing.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Operational condition of the lubricating oil system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Correct adjustment and operational condition of safety devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Locations where fluid leakage, overheating, heavy vibration or excessive gland or bearing clearances may occur.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Correct adjustment of controls and monitoring systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Operational condition of alarm systems, particularly where the reversing and reduction gearing is designed for non-continuous local supervision.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5527h0 t5527h1"><Emphasis style="italic">Shafting Systems for Propulsion, Electrical Generators and Motors</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Operational condition of the lubricating fluid system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">9.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Locations where overheating, vibration, fractures, excessive gland or bearing clearances may occur.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">10.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Screw shaft inspection, as far as practicable, without withdrawal, at the time of each dry-docking with the stern bearing wear-down being determined and recorded.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5527h0 t5527h1"><Emphasis style="italic">Fixed Pitch, Controllable Pitch and Directional Propellers</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">11.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Operational condition of the propellers.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">12.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Correct adjustment of all controls and monitoring systems of controllable pitch and directional propellers.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">13.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Controllable pitch and directional propellers for any evidence of control fluid leakage.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5527h0">14.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5527h1">Operational condition of all alarm systems for controllable pitch and directional propellers.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic Special Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" align="left" htmlwidth="11%" /><colspec colname="COLSPEC25" colwidth="7.43*" htmlwidth="7%" /><colspec colname="2" colwidth="92.62*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5528h0">Item</entry><entry namest="COLSPEC25" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5528h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5528h0 t5528h1"><Emphasis style="italic">Reversing and Reduction Gearing</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0">1.</entry><entry namest="COLSPEC25" nameend="2" colsep="0" rowsep="0" headers="t5528h1">Subject to item 2, casing, pinions, wheels, shafts, couplings, clutches, glands, thrust bearing and selected other bearings, following removal of casing main cover.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0">2.</entry><entry namest="COLSPEC25" nameend="2" colsep="0" rowsep="0" headers="t5528h1">Removal of casing main cover is not required if vibration or oil analysis, inspection through inspection doors and condition monitoring shows that the condition of the components is adequate for further service.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0">3.</entry><entry namest="COLSPEC25" nameend="2" colsep="0" rowsep="0" headers="t5528h1">Gear-case ventilating system and safety devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0">4.</entry><entry namest="COLSPEC25" nameend="2" colsep="0" rowsep="0" headers="t5528h1">Oil-flow indicating, filtering and temperature monitoring devices.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5528h0 t5528h1"><Emphasis style="italic">Shafting Systems for Propulsion, Electrical Generators and Motors</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0">5.</entry><entry namest="COLSPEC25" nameend="2" colsep="0" rowsep="0" headers="t5528h1">For intermediate shafts, thrust shafts, electrical generators and motor shafts</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0"></entry><entry colsep="0" rowsep="0" headers="t5528h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5528h1">bearings, thrust pads and shaft surfaces following lifting of the upper half of the bearing and removal of thrust pads, and the lower half of the bearing shall be exposed if alignment and wear are unacceptable in accordance with rules or codes and the manufacturer’s recommendations;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0"></entry><entry colsep="0" rowsep="0" headers="t5528h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5528h1">bearing securing arrangements; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0"></entry><entry colsep="0" rowsep="0" headers="t5528h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5528h1">lubricating oil system and temperature monitoring devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0">6.</entry><entry namest="COLSPEC25" nameend="2" colsep="0" rowsep="0" headers="t5528h1">For screw shafts,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0"></entry><entry colsep="0" rowsep="0" headers="t5528h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5528h1">shaft surfaces, liners, glands, key and keyway, nuts, locking devices and, as far as practicable, the stern bearing and tube, following shaft withdrawal; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0"></entry><entry colsep="0" rowsep="0" headers="t5528h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5528h1">uncoated surfaces of water lubricated carbon steel shafts adjacent to the ends of the non-continuous liners and at the forward end of the sharp edged keyway by means of a magnetic-particle, dye-penetrant or other crack detection method.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5528h0 t5528h1"><Emphasis style="italic">Fixed Pitch, Controllable Pitch and Directional Propellers</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0">7.</entry><entry namest="COLSPEC25" nameend="2" colsep="0" rowsep="0" headers="t5528h1">For fixed pitch propellers,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0"></entry><entry colsep="0" rowsep="0" headers="t5528h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5528h1">the propeller, the nut, locking devices and cone, following removal from the shaft; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0"></entry><entry colsep="0" rowsep="0" headers="t5528h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5528h1">installation of the propeller to the shaft in respect of correct propeller reassembly on the shaft.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0">8.</entry><entry namest="COLSPEC25" nameend="2" colsep="0" rowsep="0" headers="t5528h1">For controllable pitch or directional propellers,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0"></entry><entry colsep="0" rowsep="0" headers="t5528h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5528h1">operating-fluid systems and blade-position control devices;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0"></entry><entry colsep="0" rowsep="0" headers="t5528h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5528h1">blades, hub and internal gearing;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0"></entry><entry colsep="0" rowsep="0" headers="t5528h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5528h1">installation in respect of correct reassembly and operation; and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5528h0"></entry><entry colsep="0" rowsep="0" headers="t5528h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5528h1">all items, where applicable, set out in Division I, following completion of special periodic inspection.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" align="left" htmlwidth="11%" /><colspec colname="COLSPEC26" colwidth="7.55*" htmlwidth="7%" /><colspec colname="2" colwidth="92.50*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5529h0">Item</entry><entry namest="COLSPEC26" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5529h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5529h0 t5529h1"><Emphasis style="italic">Reversing and Reduction Gearing</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0">1.</entry><entry namest="COLSPEC26" nameend="2" colsep="0" rowsep="0" headers="t5529h1">At intervals not exceeding 5 years.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5529h0 t5529h1"><Emphasis style="italic">Shafting Systems for Propulsion, Electrical Generators and Motors</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0">2.</entry><entry namest="COLSPEC26" nameend="2" colsep="0" rowsep="0" headers="t5529h1">Intermediate shafts, thrust shafts, electrical generators and motor shafts, at intervals not exceeding 5 years.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0">3.</entry><entry namest="COLSPEC26" nameend="2" colsep="0" rowsep="0" headers="t5529h1">Subject to items 4 to 7, screw shafts at intervals not exceeding 5 years.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0">4.</entry><entry namest="COLSPEC26" nameend="2" colsep="0" rowsep="0" headers="t5529h1">Screw shafts in ships referred to in subsection 407(1) of the Act, at intervals not exceeding 4 years.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0">5.</entry><entry namest="COLSPEC26" nameend="2" colsep="0" rowsep="0" headers="t5529h1">Screw shafts that meet the requirements of subitem 1(<Emphasis style="italic">d</Emphasis>) of Division II of Part I, at intervals not exceeding 2 years except for screw shafts in ships operating on voyages in fresh water only or between inland waters of Canada and not beyond Home Trade Class II limits where the ship operates in fresh water at least 3 months of the year, at intervals not exceeding 5 years.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0">6.</entry><entry namest="COLSPEC26" nameend="2" colsep="0" rowsep="0" headers="t5529h1">For an oil-lubricated screw shaft having a keyless taper or flange for propeller attachment, a partial inspection without shaft withdrawal, at alternate periodic special inspections, if</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0"></entry><entry colsep="0" rowsep="0" headers="t5529h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5529h1">the lubricating oil analysis shows that the oil is suitable for further service;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0"></entry><entry colsep="0" rowsep="0" headers="t5529h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5529h1">the stern bearing wear-down is within safe limits; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0"></entry><entry colsep="0" rowsep="0" headers="t5529h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5529h1">the external oil gland is disassembled and the area at the top of the taper or flange fillet is subjected to a magnetic-particle, dye-penetrant or other crack detection method.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0">7.</entry><entry namest="COLSPEC26" nameend="2" colsep="0" rowsep="0" headers="t5529h1">For a water-lubricated, corrosion-resistant metal screw shaft having a keyless taper or flange for propeller attachment, a partial inspection with limited shaft withdrawal, at alternate periodic special inspections, if</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0"></entry><entry colsep="0" rowsep="0" headers="t5529h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5529h1">the stern bearing wear-down is within safe limits; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0"></entry><entry colsep="0" rowsep="0" headers="t5529h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5529h1">the shaft is withdrawn to a sufficient distance to expose the stern bearing contact area and the area at the top of the taper or flange fillet is subjected to a magnetic-particle, dye-penetrant or other crack detection method.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5529h0 t5529h1"><Emphasis style="italic">Fixed Pitch, Controllable Pitch and Directional Propellers</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0">8.</entry><entry namest="COLSPEC26" nameend="2" colsep="0" rowsep="0" headers="t5529h1">Fixed pitch propellers, at the time of periodic special inspection of screw shafts.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0">9.</entry><entry namest="COLSPEC26" nameend="2" colsep="0" rowsep="0" headers="t5529h1">Controllable pitch propellers</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0"></entry><entry colsep="0" rowsep="0" headers="t5529h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5529h1">with hubs removed from screw shafts, at intervals not exceeding 10 years except that hubs are not required to be removed from the shafts if the securing studs or cap screws can be extracted and inspected, especially the threaded portions of hubs and securing studs or cap screws; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0"></entry><entry colsep="0" rowsep="0" headers="t5529h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5529h1">blade systems, at the time of screw shaft periodic special inspection or partial inspection with only one blade system different from the blade system examined at a previous inspection dismantled so that in the course of successive inspections all the blade systems are inspected, if mechanisms, bearing tolerances, bolting, sealing arrangements and operating fluid analyses show that the blade systems are suitable for further service.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5529h0">10.</entry><entry namest="COLSPEC26" nameend="2" colsep="0" rowsep="0" headers="t5529h1">Directional propellers, at intervals not exceeding 8 years if at the time of each dry docking the operation of the blades, bearing tolerances, bolting, sealing arrangements and operating or lubricating fluid analyses indicate that the directional propellers are suitable for further service.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;7&quot;"><ScheduleFormHeading><Label>SCHEDULE VII</Label><TitleText>STEERING SYSTEMS, SHIPSIDE COMPONENTS AND WINDLASSES</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Steering Systems</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="5"><colspec colname="1" colwidth="13.35*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC28" colwidth="8.85*" htmlwidth="7%" /><colspec colname="COLSPEC29" colwidth="10.24*" htmlwidth="8%" /><colspec colname="COLSPEC27" colwidth="10.28*" htmlwidth="8%" /><colspec colname="2" colwidth="87.67*" htmlwidth="67%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5530h0">Item</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5530h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">1.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">A steering gear compartment shall</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">be readily accessible;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">as far as practicable, be separated from propulsion machinery and auxiliary machinery spaces; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">be equipped with a means of communication with the bridge.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">2.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">All components and, in particular, non-duplicated essential components, shall be of sound and reliable construction, of adequate strength and protected against shock loading.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">3.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">For essential components, bearings that are permanently lubricated or provided with lubrication fittings shall be utilized where required for the safe operation of the ship.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">4.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">The pressure of the fluid for calculations to determine the scantlings of piping and steering gear components subjected to internal hydraulic pressure shall be at least 1.25 times the design working pressure under the operating conditions set out in item 9, taking into account any pressure that may exist in the low-pressure side of the system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">5.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">Where, due to dynamic loads on piping and steering gear components, pulsating pressures occur, the system design shall be such that fatigue does not cause material failure.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">6.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">Relief valves shall be fitted to any part of the hydraulic system that can be isolated and in which pressure can be generated from the power source or from external forces.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">7.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">Relief valve settings shall not exceed the design working pressure of the fluid set out in item 4 and the valves shall be of adequate size and arranged to avoid an undue rise in pressure above the design working pressure of the fluid.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5530h0 t5530h1"><Emphasis style="italic">Steering Gears</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">8.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">Subject to items 19 and 20, the installation shall consist of totally independent main and auxiliary steering gears.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">9.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">The main steering gear shall be designed, where the ship is at its deepest sea-going draft and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">running ahead at maximum service speed, to put the rudder over</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(i)</entry><entry namest="COLSPEC27" nameend="2" colsep="0" rowsep="0" headers="t5530h1">from 35 degrees on one side to 35 degrees on the other side, and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(ii)</entry><entry namest="COLSPEC27" nameend="2" colsep="0" rowsep="0" headers="t5530h1">from 35 degrees on either side to 30 degrees on the other side in not more than 28 seconds; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">running astern at maximum speed, for maximum rudder angle operation.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">10.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">A main steering gear shall be power-operated</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">where necessary to meet the requirements of item 9; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">where a rudder stock of over 120 mm in diameter, excluding strengthening for navigation in ice, is required at the position of tiller attachment.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">11.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">The auxiliary steering gear shall be designed, where the ship is at its deepest sea-going draft and running ahead one-half its maximum service speed or 7 knots, whichever is the greater, to put the rudder over from 15 degrees on one side to 15 degrees on the other side in not more than 60 seconds.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">12.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">The auxiliary steering gear shall have the capacity to be brought safely and speedily into action in an emergency.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">13.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">An auxiliary steering gear shall be power-operated</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">where necessary to meet the requirements of item 11; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">where a rudder stock of over 230 mm in diameter, excluding strengthening for navigation in ice, is required at the position of tiller attachment.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">14.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">A power-operated auxiliary steering gear unit and its associated control system and rudder angle indicator shall, where the rudder stock is required to be over 230 mm in diameter, excluding strengthening for navigation in ice, be provided automatically with an alternative power source within 45 seconds of the failure of the main power source, from</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">the emergency electric power source; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">an independent power source located in the steering gear compartment that is used solely for that purpose.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">15.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">The alternative power source referred to in item 14 shall</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">in any ship of 10,000 tons gross tonnage or more be capable of at least 30 minutes continuous operation; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">in any other ship, be capable of at least 10 minutes continuous operation.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">16.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">Main and auxiliary steering gear power units shall be</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">capable of being brought into operation from a location on the bridge;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">arranged to start automatically where power is restored after a power failure; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">equipped with an audible and visual alarm located on the bridge to indicate a power failure to any one power unit.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">17.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">Hydraulic power-operated main and auxiliary steering gears shall be equipped with the following:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">arrangements to maintain the cleanliness of the hydraulic fluid, taking into consideration the type and design of the hydraulic system;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">an audible and visual low-fluid-level alarm for each hydraulic fluid reservoir to give the bridge and the propulsion machinery space the earliest possible indication of hydraulic fluid leakage;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">a fixed storage tank that has a contents gauge and sufficient capacity to refill the contents of at least one power-actuating system, including the reservoir, where the main steering gear is required to be power-operated; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">means by which the hydraulic systems can be readily refilled from within the steering gear compartment through permanently connected piping leading from the storage tank.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">18.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">Electric and electrohydraulic power-operated main and auxiliary steering gears shall meet the following requirements:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">means for indicating whether the motors of the electric or electrohydraulic steering gears are running shall be installed on the bridge and at a suitable propulsion machinery control location;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">each electric or electrohydraulic steering gear comprising one or more power units shall be served by at least two exclusive circuits fed directly from the main switchboard, where one of the circuits may be supplied through the emergency switchboard;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">an electric or electrohydraulic auxiliary steering gear associated with an electric or electrohydraulic main steering gear may be connected to one of the circuits supplying the main steering gear if the circuits have adequate rating for supplying all motors that can be simultaneously connected to them and that may be required to operate simultaneously;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">short-circuit protection and an overload alarm shall be provided for the circuits and motors, and where protection against excess current including starting current is provided for a circuit or motor, the protection shall be not less than twice the full load current of the circuit or motor, as the case may be and shall be arranged to permit the passage of the appropriate starting currents;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">where a three-phase power supply is used, an alarm shall be provided to indicate failure of any one of the supply phases and the alarm shall be audible, visual and situated</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(i)</entry><entry namest="COLSPEC27" nameend="2" colsep="0" rowsep="0" headers="t5530h1">in a conspicuous location in the main machinery space or control room from which the main machinery is normally controlled, and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(ii)</entry><entry namest="COLSPEC27" nameend="2" colsep="0" rowsep="0" headers="t5530h1">as may be required by Schedule VIII;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">f</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">where an auxiliary steering gear that is in a ship of less than 1,600 tons gross tonnage and that is required to be power-operated is not electrically powered or is powered by an electric motor primarily intended for other services, the main steering gear may be fed by one circuit from the main switchboard; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">g</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">where an electric motor primarily intended for other services is arranged to power an auxiliary steering gear in a ship of less than 1,600 tons gross tonnage, protection arrangements for electric and electrohydraulic power-operated steering gears are not required to meet the requirements set out in paragraphs (<Emphasis style="italic">d</Emphasis>) and (<Emphasis style="italic">e</Emphasis>) if suitable alternative arrangements are made.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">19.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">An auxiliary steering gear is not required where main steering gear power units and connections are fitted in duplicate if</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">for ships carrying more than 12 passengers, each steering gear power unit enables the steering gear to meet the requirements of item 9;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">for ships carrying not more than 12 passengers, both steering gear power units operating together enable the steering gear to meet the requirements of item 9; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">for hydraulic-type steering gears, the main steering gear is so arranged that after a single failure in its piping or in one of the steering gear power units the defect can be isolated and steering capability can be maintained or speedily regained, and for other types of steering gear, a similar standard can be achieved.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">20.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">An auxiliary steering gear is not required for double-ended ships with two independent steering systems, one fore and one aft, if in the case of failure of one of the steering systems the corresponding rudder can be safely and speedily brought back to the centre line and kept steady in that position.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">21.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">For every tanker, chemical tanker or gas carrier of 10,000 tons gross tonnage or more and every other ship of 70,000 tons gross tonnage or more, the main steering gear shall comprise two or more identical power units that meet the requirements of item 19.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">22.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">Subject to item 23, every tanker, chemical tanker or gas carrier of 10,000 tons gross tonnage or more shall meet the following requirements:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">the main steering gear shall be so arranged that in the event of loss of steering capability due to a single failure in any part of one of the power-actuating systems of the main steering gear, excluding the tiller, quadrant or components serving the same purpose or a seizure of the rudder actuators, steering capability shall be regained in less than 45 seconds after the loss of one power actuating system;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">the main steering gear shall comprise</entry></row><row><entry colsep="0" rowsep="0" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(i)</entry><entry namest="COLSPEC27" nameend="2" colsep="0" rowsep="0" headers="t5530h1">two independent and separate power-actuating systems, each capable of meeting the requirements of item 9, or</entry></row><row><entry colsep="0" rowsep="0" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(ii)</entry><entry namest="COLSPEC27" nameend="2" colsep="0" rowsep="0" headers="t5530h1">at least two identical power-actuating systems that, acting simultaneously in normal operation, shall be capable of meeting the requirements of item 9 if</entry></row><row><entry colsep="0" rowsep="0" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1"></entry><entry colsep="0" rowsep="0" headers="t5530h1"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(A)</entry><entry colsep="0" rowsep="0" headers="t5530h1">interconnection of hydraulic power-actuating systems, where necessary, is provided, and</entry></row><row><entry colsep="0" rowsep="0" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1"></entry><entry colsep="0" rowsep="0" headers="t5530h1"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(B)</entry><entry colsep="0" rowsep="0" headers="t5530h1">loss of hydraulic fluid from one of the systems is capable of being detected and that system is automatically isolated so that the other system or systems remain fully operational; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">steering gears, other than of the hydraulic type, shall achieve a standard equivalent to the standard referred to in subitem (<Emphasis style="italic">b</Emphasis>).</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0">23.</entry><entry namest="COLSPEC28" nameend="2" colsep="0" rowsep="0" headers="t5530h1">For tankers, chemical tankers or gas carriers of 10,000 tons gross tonnage or more, but of less than 100,000 tonnes deadweight, in the event of a single failure referred to in item 22 of a rudder actuator, the requirements set out in that item are not required to be met if</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">a safety standard equivalent to the standard set out in item 22 is achieved;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">components meet the requirements of item 1 of Division II;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">following loss of steering capability due to a single failure of any part of the piping system or in one of the power units, steering capability is regained within 45 seconds; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC29" nameend="2" colsep="0" rowsep="0" headers="t5530h1">where the steering gear includes only a single rudder actuator, the following factors are taken into special consideration in the actuator design and construction:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(i)</entry><entry namest="COLSPEC27" nameend="2" colsep="0" rowsep="0" headers="t5530h1">stress analyses including, as appropriate, fatigue analysis and fracture mechanics analysis,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(ii)</entry><entry namest="COLSPEC27" nameend="2" colsep="0" rowsep="0" headers="t5530h1">materials used, and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5530h0"></entry><entry colsep="0" rowsep="0" headers="t5530h1"></entry><entry colsep="0" rowsep="0" headers="t5530h1">(iii)</entry><entry namest="COLSPEC27" nameend="2" colsep="0" rowsep="0" headers="t5530h1">hydraulic fluid sealing arrangements.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Non-Duplicated Rudder Actuators for Tankers, Chemical Tankers and Gas Carriers of 10,000 Tons Gross Tonnage or more but less than 100,000 Tonnes Deadweight</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="5"><colspec colname="1" colwidth="11.67*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC33" colwidth="7.80*" htmlwidth="7%" /><colspec colname="COLSPEC32" colwidth="23.57*" htmlwidth="21%" /><colspec colname="COLSPEC31" colwidth="31.40*" htmlwidth="27%" /><colspec colname="COLSPEC30" colwidth="40.12*" htmlwidth="35%" /><thead><row rowsep="1" topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5531h0">Item</entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="1" valign="bottom" id="t5531h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5531h0">1.</entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">Components that are subject to internal hydraulic pressure or that transmit mechanical forces to the rudder stock shall be made</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC32" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">of tested ductile materials in accordance with rules or codes; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC32" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">with pressure-retaining components that have a tensile strength of not more than 650 MPa and a percentage elongation of not less than 12 per cent.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5531h0">2.</entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">The design working pressure shall be at least equal to the greater of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC32" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">1.25 times the maximum pressure expected under the operating conditions set out in subitem 9(<Emphasis style="italic">a</Emphasis>) of Division I; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC32" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">the relief valve pressure setting.</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0">3.</entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">In determining the scantlings of components of rudder actuators subject to internal hydraulic pressure, the following stresses are permitted:</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1"></entry><entry colsep="0" rowsep="0" headers="t5531h1">Sm</entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1">shall not exceed</entry><entry colsep="0" rowsep="0" headers="t5531h1"><Leader leader="none" length="4pc" />f</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1"></entry><entry colsep="0" rowsep="0" headers="t5531h1">S1</entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1">shall not exceed</entry><entry colsep="0" rowsep="0" headers="t5531h1"><Leader leader="none" length="3pc" />1.5f</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1"></entry><entry colsep="0" rowsep="0" headers="t5531h1">Sb</entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1">shall not exceed</entry><entry colsep="0" rowsep="0" headers="t5531h1"><Leader leader="none" length="3pc" />1.5f</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1"></entry><entry colsep="0" rowsep="0" headers="t5531h1">S1 + Sb</entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1">shall not exceed</entry><entry colsep="0" rowsep="0" headers="t5531h1"><Leader leader="none" length="3pc" />1.5f</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1"></entry><entry colsep="0" rowsep="0" headers="t5531h1">Sm + Sb</entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1">shall not exceed</entry><entry colsep="0" rowsep="0" headers="t5531h1"><Leader leader="none" length="3pc" />1.5f</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">where</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1"></entry><entry namest="COLSPEC32" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1"><Provision format-ref="indent-0-0"><FormulaGroup><FormulaDefinition><FormulaTerm>Sm</FormulaTerm><Text>is the equivalent primary general membrane stress</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>S1</FormulaTerm><Text>is the equivalent primary local membrane stress</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>Sb</FormulaTerm><Text>is the equivalent primary bending stress</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>f</FormulaTerm><Text>is the lesser of S<Sub>B/A</Sub> or S<Sub>Y/B</Sub></Text></FormulaDefinition><FormulaDefinition><FormulaTerm>S<Sub>B</Sub></FormulaTerm><Text>is the specified minimum tensile strength of material at ambient temperature</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>S<Sub>y</Sub></FormulaTerm><Text>is the specified minimum yield stress or 0.2 per cent proof stress of material at ambient temperature</Text></FormulaDefinition></FormulaGroup></Provision></entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1"></entry><entry namest="COLSPEC32" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">A and B are as follows:</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1"></entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1"><Emphasis style="underline">Steel</Emphasis></entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1"><Emphasis style="underline">Cast Steel</Emphasis></entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1"><Emphasis style="underline">Nodular Cast Iron</Emphasis></entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" align="right" headers="t5531h1">A</entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1">4</entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1">4.6</entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1">5.8</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" align="right" headers="t5531h1">B</entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1">2</entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1">2.3</entry><entry colsep="0" rowsep="0" align="center" headers="t5531h1">3.5</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0">4.</entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">Pressure-retaining components not requiring fatigue analysis and fracture mechanics analysis in accordance with subitem 7(<Emphasis style="italic">d</Emphasis>) of Division I of Part II are acceptable on the basis of a certified burst test and in that case, the detailed stress analysis required by subitem 7(<Emphasis style="italic">c</Emphasis>) of Division I of Part II is not required.</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0">5.</entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">The minimum bursting pressure shall be calculated as follows:</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1"></entry><entry namest="COLSPEC32" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1"><Provision format-ref="indent-0-0"><Text>P<Sub>b</Sub> = P. A s<Sub>Ba/SB</Sub></Text></Provision></entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">where</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1"></entry><entry namest="COLSPEC32" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1"><Provision format-ref="indent-0-0"><FormulaGroup><FormulaDefinition><FormulaTerm>P<Sub>b</Sub></FormulaTerm><Text>is the minimum bursting pressure</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>P</FormulaTerm><Text>is the design working pressure as set out in item 2</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>A</FormulaTerm><Text>is the applicable value set out in the table to item 3</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>S<Sub>Ba</Sub></FormulaTerm><Text>is the actual tensile strength</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>S<Sub>B</Sub></FormulaTerm><Text>is the tensile strength determined in accordance with item 3</Text></FormulaDefinition></FormulaGroup></Provision></entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0">6.</entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">The construction shall minimize local concentrations of stress and all welded joints within the pressure boundary of a rudder actuator or connecting parts transmitting mechanical loads shall be of the full penetration type or of an equivalent strength.</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0">7.</entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">Oil seals between non-moving components, forming part of the external pressure boundary, shall be of the metal-on-metal type or of an equivalent type.</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0">8.</entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">Oil seals between moving components, forming part of the external pressure boundary, shall be duplicated, so that the failure of one seal does not render the actuator inoperative, or shall have sealing arrangements providing equivalent protection against leakage.</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0">9.</entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">Isolating valves shall be fitted at the connection of pipes to the actuator and shall be directly mounted on the actuator.</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0">10.</entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">Relief valves for protecting the rudder actuator against over-pressure as required by items 6 and 7 of Division I shall meet the following requirements:</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC32" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">the setting pressure shall not be less than 1.25 times the maximum pressure expected under the operating conditions set out in subitem 9(<Emphasis style="italic">a</Emphasis>) of Division I;</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC32" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">the minimum discharge capacity of the relief valves shall not be less than the total capacity of all pumps that provide power for the actuator, increased by 10 per cent;</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC32" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">under operating conditions the rise in pressure shall not exceed 10 per cent of the setting pressure; and</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0"></entry><entry colsep="0" rowsep="0" headers="t5531h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC32" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">in respect of subitems (<Emphasis style="italic">b</Emphasis>) and (<Emphasis style="italic">c</Emphasis>), account shall be given to extreme foreseen ambient conditions in respect of oil viscosity.</entry></row><row><entry colsep="0" rowsep="0" headers="t5531h0">11.</entry><entry namest="COLSPEC33" nameend="COLSPEC30" colsep="0" rowsep="0" headers="t5531h1">The rudder actuator shall be subjected to non-destructive testing in accordance with rules or codes to detect both surface flaws and volumetric flaws, and fracture mechanics analysis may be used for determining maximum allowable flaw size.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division III</Label><TitleText>Steering Controls</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" align="left" htmlwidth="11%" /><colspec colname="COLSPEC34" colwidth="7.55*" htmlwidth="7%" /><colspec colname="2" colwidth="92.50*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5532h0">Item</entry><entry namest="COLSPEC34" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5532h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0">1.</entry><entry namest="COLSPEC34" nameend="2" colsep="0" rowsep="0" headers="t5532h1">Steering-wheels or lever pointers shall</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0"></entry><entry colsep="0" rowsep="0" headers="t5532h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5532h1">move to starboard to turn the bow of the ship to starboard; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0"></entry><entry colsep="0" rowsep="0" headers="t5532h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5532h1">move to port to turn the bow of the ship to port.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0">2.</entry><entry namest="COLSPEC34" nameend="2" colsep="0" rowsep="0" headers="t5532h1">A rudder direction and angle indicator, independent of the remote steering gear control system, shall be fitted on the bridge where the main steering system is power-operated or the length of the ship exceeds 20 m.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0">3.</entry><entry namest="COLSPEC34" nameend="2" colsep="0" rowsep="0" headers="t5532h1">Main steering gears shall be controllable from the bridge and from an alternative location in the steering gear compartment or other suitable location taking into account operational and risk factors.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0">4.</entry><entry namest="COLSPEC34" nameend="2" colsep="0" rowsep="0" headers="t5532h1">A rudder angle indicator shall be fitted at the alternative location referred to in item 3.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0">5.</entry><entry namest="COLSPEC34" nameend="2" colsep="0" rowsep="0" headers="t5532h1">Subject to item 6, two independent remote control systems, not including the steering-wheel or lever, shall be fitted where a duplicate main steering gear system is fitted.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0">6.</entry><entry namest="COLSPEC34" nameend="2" colsep="0" rowsep="0" headers="t5532h1">Except in a tanker, chemical tanker or gas carrier of 10,000 tons gross tonnage or more a second independent control system is not required to be fitted where the control system is a hydraulic telemotor.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0">7.</entry><entry namest="COLSPEC34" nameend="2" colsep="0" rowsep="0" headers="t5532h1">The auxiliary steering gear shall be controllable from the steering gear compartment and, if power-operated, shall be operable from the bridge and independent of the main steering gear control system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0">8.</entry><entry namest="COLSPEC34" nameend="2" colsep="0" rowsep="0" headers="t5532h1">Any main and auxiliary steering gear control system operable from the bridge shall meet the following requirements:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0"></entry><entry colsep="0" rowsep="0" headers="t5532h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5532h1">if electric, it shall be served by its own separate circuit supplied from a steering gear power circuit from a point within the steering gear compartment or directly from switchboard busbars supplying that steering gear power circuit at a point on the switchboard adjacent to the supply to the steering gear power circuit;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0"></entry><entry colsep="0" rowsep="0" headers="t5532h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5532h1">means shall be provided in the steering gear compartment for disconnecting any control system that is operable from the bridge to the steering gear it serves;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0"></entry><entry colsep="0" rowsep="0" headers="t5532h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5532h1">the system shall be capable of being brought into operation from a location on the bridge;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0"></entry><entry colsep="0" rowsep="0" headers="t5532h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5532h1">in the event of a failure of the electrical power supply to the control system, an audible and visual alarm shall be given on the bridge; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0"></entry><entry colsep="0" rowsep="0" headers="t5532h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5532h1">short circuit protection only shall be provided for steering gear control supply circuits.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5532h0">9.</entry><entry namest="COLSPEC34" nameend="2" colsep="0" rowsep="0" headers="t5532h1">Duplicate steering gear control systems, including pipes, electric power circuits and their components shall be separated, as far as practicable, throughout their length.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division IV</Label><TitleText>Shipside Components</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="12.67*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC36" colwidth="8.53*" htmlwidth="7%" /><colspec colname="COLSPEC35" colwidth="9.04*" htmlwidth="7%" /><colspec colname="2" colwidth="92.84*" htmlwidth="75%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5533h0">Item</entry><entry namest="COLSPEC36" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5533h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5533h0">1.</entry><entry namest="COLSPEC36" nameend="2" colsep="0" rowsep="0" headers="t5533h1">For ships required to operate in ice-covered waters where ice may choke sea-water inlets, maintenance of essential sea-water supply shall be maintained by</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5533h0"></entry><entry colsep="0" rowsep="0" headers="t5533h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC35" nameend="2" colsep="0" rowsep="0" headers="t5533h1">diversion arrangements for warmed cooling water from overboard discharges into sea- water inlet boxes;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5533h0"></entry><entry colsep="0" rowsep="0" headers="t5533h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC35" nameend="2" colsep="0" rowsep="0" headers="t5533h1">means to clear sea-water inlet boxes, preferably by steam that has a pressure not in excess of the design working pressure of the sea-water inlet boxes and that is vented to the upper deck by means of a valved pipe; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5533h0"></entry><entry colsep="0" rowsep="0" headers="t5533h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC35" nameend="2" colsep="0" rowsep="0" headers="t5533h1">ensuring sea-water inlet strainers have</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5533h0"></entry><entry colsep="0" rowsep="0" headers="t5533h1"></entry><entry colsep="0" rowsep="0" headers="t5533h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5533h1">perforations approximately 20 mm in diameter to prevent ingestion of large ice particles, and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5533h0"></entry><entry colsep="0" rowsep="0" headers="t5533h1"></entry><entry colsep="0" rowsep="0" headers="t5533h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5533h1">a strainer perforated area approximately 5 times the total cross-sectional area of the inlet pipes being served to ensure full fluid flow in slush ice conditions.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division V</Label><TitleText>Windlasses</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5534h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5534h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5534h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5534h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Steering Systems</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="12.76*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC38" colwidth="8.57*" htmlwidth="7%" /><colspec colname="COLSPEC37" colwidth="9.09*" htmlwidth="7%" /><colspec colname="2" colwidth="93.38*" htmlwidth="75%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5535h0">Item</entry><entry namest="COLSPEC38" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5535h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0">1.</entry><entry namest="COLSPEC38" nameend="2" colsep="0" rowsep="0" headers="t5535h1">General arrangement of the main, and duplicate or auxiliary, steering systems in the ship.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0">2.</entry><entry namest="COLSPEC38" nameend="2" colsep="0" rowsep="0" headers="t5535h1">General arrangement and sectional elevation of the steering gears, including holding-down arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0">3.</entry><entry namest="COLSPEC38" nameend="2" colsep="0" rowsep="0" headers="t5535h1">Specifications indicating maximum designed torque at rudder stock, timing and angle of rudder movements for main and auxiliary steering gears, materials and physical properties of the principal components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0">4.</entry><entry namest="COLSPEC38" nameend="2" colsep="0" rowsep="0" headers="t5535h1">Details of pumps, piping and valves subjected to pressure, and securing arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0">5.</entry><entry namest="COLSPEC38" nameend="2" colsep="0" rowsep="0" headers="t5535h1">Details of safety and shock-prevention devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0">6.</entry><entry namest="COLSPEC38" nameend="2" colsep="0" rowsep="0" headers="t5535h1">Details of control and monitoring mechanisms including connections to all steering locations.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0">7.</entry><entry namest="COLSPEC38" nameend="2" colsep="0" rowsep="0" headers="t5535h1">For non-duplicated rudder actuators in tankers, chemical tankers and gas carriers of 10,000 tons gross tonnage or more but less than 100,000 tonnes deadweight,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0"></entry><entry colsep="0" rowsep="0" headers="t5535h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC37" nameend="2" colsep="0" rowsep="0" headers="t5535h1">welding details and processes;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0"></entry><entry colsep="0" rowsep="0" headers="t5535h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC37" nameend="2" colsep="0" rowsep="0" headers="t5535h1">detailed design calculations;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0"></entry><entry colsep="0" rowsep="0" headers="t5535h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC37" nameend="2" colsep="0" rowsep="0" headers="t5535h1">stress analysis of the pressure-retaining components;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0"></entry><entry colsep="0" rowsep="0" headers="t5535h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC37" nameend="2" colsep="0" rowsep="0" headers="t5535h1">depending on design complexity, unusual manufacturing processes and foreseen dynamic load, the Board may require</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0"></entry><entry colsep="0" rowsep="0" headers="t5535h1"></entry><entry colsep="0" rowsep="0" headers="t5535h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5535h1">a fatigue analysis, and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0"></entry><entry colsep="0" rowsep="0" headers="t5535h1"></entry><entry colsep="0" rowsep="0" headers="t5535h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5535h1">a fracture mechanics analysis; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0"></entry><entry colsep="0" rowsep="0" headers="t5535h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry namest="COLSPEC37" nameend="2" colsep="0" rowsep="0" headers="t5535h1">the Board may require experimental stress analysis in support of, or in lieu of, the theoretical analyses referred to in subitem (<Emphasis style="italic">d</Emphasis>).</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0">8.</entry><entry namest="COLSPEC38" nameend="2" colsep="0" rowsep="0" headers="t5535h1">Information for valves and similar minor components referred to in item 4 is not required to be submitted where a manufacturer or an approved classification society certifies that the types of valves or similar minor components have been designed and constructed in accordance with rules or codes.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5535h0">9.</entry><entry namest="COLSPEC38" nameend="2" colsep="0" rowsep="0" headers="t5535h1">Information for pumps referred to in item 4 is not required to be submitted where an approved classification society certifies that the pumps have been designed and constructed in accordance with rules or codes, except that the driving motor or engines of the pumps shall meet the requirements of Part II of the applicable schedule of Schedules I to XV.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Shipside Components</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5536h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5536h1">Required Information</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5536h0 t5536h1"><Emphasis style="italic">Shafting and Valves</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5536h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5536h1">Details of shipside penetrating shafting and glands, including fin stabilizing components, their locking mechanisms and other connections.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5536h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5536h1">Details of sea inlet and discharge valves and strainers and their connections, including those for side thrusters and deck wash systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5536h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5536h1">For ships required to operate in ice-covered waters, details of arrangements to prevent slush ice choking sea-water inlets.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5536h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5536h1">Specifications indicating the maximum stresses of the shafting, valve pressures and flow rates, materials and physical properties of the principal components.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5536h0 t5536h1"><Emphasis style="italic">Door-operating Mechanisms</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5536h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5536h1">General arrangement of door-operating mechanisms showing all connected machinery and their locations in the ship.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5536h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5536h1">Details of all components, including pumps, piping and valves subjected to pressure and securing arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5536h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5536h1">Specifications indicating maximum stresses, materials and physical properties of principal components, particularly those that may be subjected to low ambient temperatures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5536h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5536h1">Information for valves and similar minor components referred to in items 2 and 6 is not required to be submitted where a manufacturer or an approved classification society certifies that the types of valves or similar minor components have been designed and constructed in accordance with rules or codes.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5536h0">9.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5536h1">Information for pumps referred to in item 6 is not required to be submitted where an approved classification society certifies that the pumps have been designed and constructed in accordance with rules or codes, except that the driving motor or engines of the pumps shall meet the requirements of Part II of the applicable schedule of Schedules I to XV.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division III</Label><TitleText>Windlasses</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5537h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5537h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5537h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5537h1">General arrangement, including type of power and loads, of the windlass systems showing all connected machinery and their location in the ship.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5537h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5537h1">Details of all windlass components, including pumps, piping, valves and brakes, and securing arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5537h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5537h1">Specifications indicating maximum stresses, materials and physical properties of principal components, particularly those which may be subjected to low ambient temperatures.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5537h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5537h1">Information for windlasses referred to in items 2 and 3 is not required to be submitted where an approved classification society certifies that the windlasses have been designed and constructed in accordance with rules or codes except that the driving motor or engines of the pumps shall meet the requirements of Part II of the applicable schedule of Schedules I to XV.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" align="left" htmlwidth="11%" /><colspec colname="COLSPEC39" colwidth="7.55*" htmlwidth="7%" /><colspec colname="2" colwidth="92.50*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5538h0">Item</entry><entry namest="COLSPEC39" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5538h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5538h0 t5538h1"><Emphasis style="italic">Steering Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5538h0">1.</entry><entry namest="COLSPEC39" nameend="2" colsep="0" rowsep="0" headers="t5538h1">Identification from material test certificates, before construction is commenced, of materials to be used, including welding metal, for the following parts:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5538h0"></entry><entry colsep="0" rowsep="0" headers="t5538h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5538h1">rams, frames, pintles and other components under stress when transmitting torque to the rudder stock; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5538h0"></entry><entry colsep="0" rowsep="0" headers="t5538h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5538h1">cylinders and other components retaining pressure.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5538h0">2.</entry><entry namest="COLSPEC39" nameend="2" colsep="0" rowsep="0" headers="t5538h1">Verification that welding was carried out by welders certified by a Provincial Government of Canada, or another authority having similar standards where the welding was carried out outside Canada, for the class of work to be done.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5538h0">3.</entry><entry namest="COLSPEC39" nameend="2" colsep="0" rowsep="0" headers="t5538h1">Inspection of welds, including non-destructive test examination and verification of the heat treatment process, in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5538h0">4.</entry><entry namest="COLSPEC39" nameend="2" colsep="0" rowsep="0" headers="t5538h1">Identification of components from component inspection certificates and inspection of components and their installation.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5538h0">5.</entry><entry namest="COLSPEC39" nameend="2" colsep="0" rowsep="0" headers="t5538h1">Witnessing of hydrostatic pressure testing of components in accordance with rules or codes, except that for non-duplicated rudder actuator pressure components in tankers, chemical tankers and gas carriers of 10,000 tons gross tonnage or more but less than 100,000 tonnes deadweight, the hydrostatic pressure test is to be at 1.5 times the design working pressure.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5538h0">6.</entry><entry namest="COLSPEC39" nameend="2" colsep="0" rowsep="0" headers="t5538h1">Inspection of the constructed steering gear and the witnessing of the gearing operation under test.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5538h0 t5538h1"><Emphasis style="italic">Shipside Components and Windlasses</Emphasis></entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5538h0">7.</entry><entry namest="COLSPEC39" nameend="2" colsep="0" rowsep="0" headers="t5538h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Installation Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5539h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5539h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5539h0 t5539h1"><Emphasis style="italic">Steering Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5539h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5539h1">Identification from component inspection certificates, before installation is commenced, of steering systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5539h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5539h1">Verification of correct adjustment and operational condition at all steering locations of securing arrangements, connection of steering systems to associated systems, safety, control and monitoring devices and, for hydraulic power operated systems, a hydrostatic pressure test at the design working pressure.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5539h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5539h1">Inspection of change-over from main to duplicate or auxiliary steering systems in accordance with the design specifications set out in Part I.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5539h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5539h1">Verification of reliability and sufficiency of both main, and duplicate or auxiliary steering systems under trials for a sufficient endurance period up to the ship’s maximum propulsion power for main and duplicate systems and up to navigable speed for the auxiliary system in accordance with design specifications set out in Division I of Part I, except that the steering gear need not necessarily be demonstrated at maximum rudder angle operation while running astern at maximum speed.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5539h0 t5539h1"><Emphasis style="italic">Shipside Components and Windlasses</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5539h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5539h1">Identification from component inspection certificates, before installation is commenced, of shipside components, including door-operating mechanisms, and windlasses.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5539h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5539h1">Verification of correct adjustment and operational condition of securing arrangements, connection of the components and windlasses to associated systems, safety, control and monitoring devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5539h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5539h1">Inspection of shafts, glands, strainers and valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5539h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5539h1">Inspection to ensure that no overboard discharges are in the way of lifeboat or liferaft lowering locations.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5539h0">9.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5539h1">Witnessing of operational tests of the components and windlasses in accordance with rules or codes.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5540h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5540h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5540h0 t5540h1"><Emphasis style="italic">Steering Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5540h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5540h1">Operational condition and controllability of steering systems from all steering locations.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5540h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5540h1">Capability of duplicate or auxiliary steering systems to be brought rapidly into operation.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5540h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5540h1">Correct adjustment and operational condition of alarm and monitoring devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5540h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5540h1">Correct adjustment and operational condition of safety devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5540h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5540h1">Locations where fluid leakage, overheating, excessive vibration, fractures or excessive gland or bearing clearances may occur, particularly where the steering gear includes only a single rudder actuator.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5540h0 t5540h1"><Emphasis style="italic">Shipside Components and Windlasses</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5540h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5540h1">Operational conditional and controllability of components including door-operating mechanisms and windlass braking systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5540h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5540h1">Locations where excessive fluid leakage, metal wastage, vibration or fractures may occur.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5540h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5540h1">Overboard discharges to confirm that no overboard discharges above the ship waterline are in the way of lifeboat or liferaft lowering positions.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic Special Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot" colsep="0" rowsep="0"><tgroup cols="2"><colspec colname="1" colwidth="10.67*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.33*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5541h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5541h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" headers="t5541h0 t5541h1"><Emphasis style="italic">Steering Systems</Emphasis></entry></row><row><entry colname="1" valign="top" headers="t5541h0">1.</entry><entry colname="2" valign="top" headers="t5541h1">Subject to item 4, driving engines or pumps, actuators, piping, pintles and bearings.</entry></row><row><entry colname="1" valign="top" headers="t5541h0">2.</entry><entry colname="2" valign="top" headers="t5541h1">Subject to item 4, control and monitoring mechanisms leading to the bridge and other steering locations.</entry></row><row><entry colname="1" valign="top" headers="t5541h0">3.</entry><entry colname="2" valign="top" headers="t5541h1">Steering gear structure and fastenings without dismantling, if their condition is adequate on the basis of general examination.</entry></row><row><entry colname="1" valign="top" headers="t5541h0">4.</entry><entry colname="2" valign="top" headers="t5541h1">Periodic special inspection is not required for hydraulic systems if the general periodic inspection referred to in Division I and operational observation, vibration analysis or written information provided to the inspector by firms specializing in the reconditioning of these parts shows that the condition of the parts is satisfactory for further service.</entry></row><row><entry colname="1" valign="top" headers="t5541h0">5.</entry><entry colname="2" valign="top" headers="t5541h1">No periodic special inspection is required for complex mechanisms where written information is provided to the inspector by firms specializing in the reconditioning of these parts, indicating that the parts are in good order and adjustment.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" headers="t5541h0 t5541h1"><Emphasis style="italic">Shipside Components</Emphasis></entry></row><row><entry colname="1" valign="top" headers="t5541h0">6.</entry><entry colname="2" valign="top" headers="t5541h1">Internal and external parts of shipside valves, keel cooler valves, strainers and glands.</entry></row><row><entry colname="1" valign="top" headers="t5541h0">7.</entry><entry colname="2" valign="top" headers="t5541h1">Periodic special inspection is not required for hydraulic pumps, cylinders, rams and piping if the periodic general inspection referred to in Division I and operational observation, vibration analysis or written information provided to the inspector by firms specializing in the reconditioning of these parts shows that the condition of the parts is satisfactory for further service.</entry></row><row bottommarginspacing="2"><entry colname="1" valign="top" headers="t5541h0">8.</entry><entry colname="2" valign="top" headers="t5541h1">No periodic special inspection is required for complex mechanisms where written information is provided to the inspector by firms specializing in the reconditioning of these parts, indicating that the parts are in good order and adjustment.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5542h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5542h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5542h0 t5542h1"><Emphasis style="italic">Steering Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5542h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5542h1">At intervals not exceeding 5 years.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5542h0 t5542h1"><Emphasis style="italic">Shipside Components</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5542h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5542h1">Shipside valves, keel cooler valves, strainers, shafts and glands, at intervals not exceeding 4 years except where the ship is dry docked at intervals of 5 years in accordance with the <XRefExternal reference-type="regulation" link="C.R.C.,_c._1432">Hull Inspection Regulations</XRefExternal>, at that time.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5542h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5542h1">All other components including door-operating mechanisms, at intervals not exceeding 5 years.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;8&quot;"><ScheduleFormHeading><Label>SCHEDULE VIII</Label><TitleText>REMOTE CONTROL AND MONITORING SYSTEMS IN PERIODICALLY UNATTENDED MACHINERY SPACES</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Application</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="3.67*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC32" colwidth="2.43*" htmlwidth="7%" /><colspec colname="COLSPEC41" colwidth="2.58*" align="left" htmlwidth="7%" /><colspec colname="COLSPEC40" colwidth="26.46*" align="left" htmlwidth="75%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5543h0">Item</entry><entry namest="COLSPEC32" nameend="COLSPEC40" colsep="0" rowsep="1" valign="bottom" id="t5543h1">Description of Ships</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0">1.</entry><entry namest="COLSPEC32" nameend="COLSPEC40" colsep="0" rowsep="0" headers="t5543h1">In this schedule,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry namest="COLSPEC32" nameend="COLSPEC40" colsep="0" rowsep="0" headers="t5543h1">“Group 1 ship” means a ship in which machinery is controlled and monitored from the bridge and engineers do not maintain surveillance watch duties in the machinery spaces and that is certificated for the following voyages:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5543h1">Foreign Going, Home Trade Class I or II or Inland Waters Class I; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5543h1">Home Trade Class III or IV, Inland Waters Class II or Minor Waters where the propulsion total brake power of the ship exceeds 2000 kW;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry namest="COLSPEC32" nameend="COLSPEC40" colsep="0" rowsep="0" headers="t5543h1">“Group 2 ship” means a ship in which machinery may be controlled from the bridge and at least one engineer is on watch in a remote central control room location only and that is certificated for the following voyages:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5543h1">Foreign Going, Home Trade Class I or II or Inland Waters Class I; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5543h1">Home Trade Class III or IV, Inland Waters Class II or Minor Waters where the propulsion total brake power of the ship exceeds 2000 kW;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry namest="COLSPEC32" nameend="COLSPEC40" colsep="0" rowsep="0" headers="t5543h1">“Group 3 ship” means a ship</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5543h1">that has main propulsion and ship service reciprocating type-internal combustion engines;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5543h1">in which machinery is controlled and monitored from the bridge or a central control room;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5543h1">that is certificated for Home Trade voyages Class III or IV, Inland Waters Class II or Minor Waters voyages where the propulsion total brake power of the ship does not exceed 2000 kW; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5543h1">in which engineering personnel do not maintain surveillance watch duties within the machinery space.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0">2.</entry><entry namest="COLSPEC32" nameend="COLSPEC40" colsep="0" rowsep="0" headers="t5543h1">This Schedule does not apply to Group 1, 2 or 3 ships that are</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC41" nameend="COLSPEC40" colsep="0" rowsep="0" headers="t5543h1">passenger ships;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC41" nameend="COLSPEC40" colsep="0" rowsep="0" headers="t5543h1">non-passenger ships fitted with a remote machinery control location, which may be the bridge, where</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(i)</entry><entry colsep="0" rowsep="0" headers="t5543h1">the machinery space is continuously manned by an engineer maintaining surveillance watch duties who is capable of locally controlling the machinery, and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(ii)</entry><entry colsep="0" rowsep="0" headers="t5543h1">bridge-to-machinery-space telegraphic and telephonic communication systems are fitted; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC41" nameend="COLSPEC40" colsep="0" rowsep="0" headers="t5543h1">non-passenger ships fitted with a machinery control location in a room within, or immediately adjacent to, the machinery space where</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(i)</entry><entry colsep="0" rowsep="0" headers="t5543h1">engineering personnel maintain regular surveillance watch duties within the machinery space, and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5543h0"></entry><entry colsep="0" rowsep="0" headers="t5543h1"></entry><entry colsep="0" rowsep="0" headers="t5543h1">(ii)</entry><entry colsep="0" rowsep="0" headers="t5543h1">an audible and visual alarm system provides a means to alert engineering personnel to return to the control location room.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Group 1, 2 and 3 Ships</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="12.75*" align="left" htmlwidth="10%" /><colspec colname="COLSPEC43" colwidth="8.45*" htmlwidth="7%" /><colspec colname="COLSPEC42" colwidth="9.22*" htmlwidth="7%" /><colspec colname="2" colwidth="93.40*" htmlwidth="75%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5544h0">Item</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5544h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">1.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">Remote and automatic control and monitoring of machinery located in periodically unattended spaces shall offer the same level of safety from remote control locations as would be obtained if the machinery were arranged for continuous local manual control and monitoring by watchkeeping engineers.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">2.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">Control, monitoring and safety devices and their location shall meet the requirements set out in rules or codes in respect of ship motion, structural vibration and atmospheric environment.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">3.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">Every enclosed central control location shall have two means of access located remote from each other, except where such enclosures are so small that two means of access are impracticable.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">4.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">Two sources of power to ensure continuous operation shall be provided for control, monitoring and alarm systems, and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">where electrical power is used,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5544h1">the systems shall be served by at least two exclusive circuits fed directly from the main switchboard, and one of the circuits shall be supplied through the emergency switchboard, where fitted, and these circuits shall not supply power for any other machinery, and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5544h1">a main-line disconnect or circuit-breaker for all console power shall be provided in a readily accessible location;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">where pneumatic power is used, each source shall consist of an air compressor, separately supplied with power, and an air receiver, both of adequate capacity and arranged to allow cross connection or isolation; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">where hydraulic power is used, these sources shall be separate from any other hydraulic service requirements and each hydraulic pump shall be separately supplied with power.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">5.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">Failure of control, monitoring and alarm systems or their power supply shall activate an audible and visual alarm at the central control location.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">6.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">An audible and visual alarm system shall be provided to indicate any fault requiring attention and shall</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">be capable of sounding an audible alarm in the main machinery control room or at the propulsion machinery remote control location and of indicating each separate alarm function visually at a suitable location;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">be connected to the engineers’ public rooms and to each of the engineers’ cabins through a selector switch that connects to at least one of the cabins at all times;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">activate an audible and visual alarm on the bridge for any situation that requires action by or the attention of the officer on watch;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">as far as practicable, be designed to have fail safe characteristics; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">activate the alarm in the engineers’ public rooms and cabins if an alarm has not received attention locally within a set time.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">7.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">The alarm system shall be equipped to indicate at the same time more than one fault and the acceptance of an alarm shall not inhibit another alarm.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">8.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">Acceptance at either of the locations referred to in subitem 6(<Emphasis style="italic">a</Emphasis>) of an alarm shall be indicated at the location where the alarm was activated.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">9.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">An audible alarm shall sound until it is accepted and the visual indication of the alarm shall remain until the fault has been corrected, after which the alarm system shall automatically reset to the normal operating condition.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">10.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">Machinery controls shall be designed to remain accurate throughout the operating range and to have fail safe characteristics.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">11.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">Machinery controls shall be robust and easy to operate, not cause undue stress in systems being controlled and operate in a logical direction and sequence with a detent at the stop or neutral position.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">12.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">A safety system shall be provided to ensure that a serious malfunction in boiler and other machinery operations that presents an immediate danger initiates the automatic shut-down of the boiler or other machinery and activates an alarm, except that shut-down of the propulsion system shall only be automatically activated in cases that could lead to serious damage, complete breakdown or explosion.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">13.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">Where arrangements for overriding the shut-down of the main propelling machinery are fitted, the arrangements shall be such as to preclude inadvertent operation, and visual means shall be provided to indicate when the override has been activated.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">14.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">Remote-controlled machinery systems and periodically unattended machinery spaces shall be equipped as follows:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">a fire detection and alarm system shall be fitted that is capable of providing coverage</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5544h1">throughout the machinery spaces, and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5544h1">in boiler air supply and exhaust casings and internal combustion engine scavenge air belts on ships of 500 tons gross tonnage or more, where the casings and air belts are prone to fire;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">fire detection and alarm systems shall be used and the location of scanners and types of detectors shall be based on the heat and smoke hazards involved and the required sensitivity of operation;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">a fire control system with associated equipment shall be fitted in all machinery spaces to provide fire-fighting capability in accordance with the <XRefExternal reference-type="regulation" link="C.R.C.,_c._1422">Fire Detection and Extinguishing Equipment Regulations</XRefExternal>;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">the remote fire control system shall be operable from an accessible location outside the machinery spaces;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">the fire control location shall have instructions posted and all arrangements necessary for the operation of the system including, where applicable, stopping of machinery and fans, closing of valves, starting of remote fire pumps and release of smothering gas;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">f</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">guards shall be provided to prevent leakage of oil from fuel oil systems from dripping or spraying onto hot surfaces; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">g</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">a fuel leakage collector system leading to a collector tank and fitted with an alarm to indicate leakage shall be fitted except where surveillance is required in accordance with item 67 of Subdivision II of Division IV for ships exempted from carrying watchkeeping engineers.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">15.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">A reliable means of voice communication shall be provided between the main machinery control location or propulsion machinery control location and the bridge, the engineers’ cabins and the engineers’ public rooms.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">16.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">Propulsion machinery orders from the bridge shall be indicated in the main machinery control room or at the propulsion machinery control station.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">17.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">Manuals for the proper operation and maintenance of remote control and monitoring systems, containing all necessary information for normal and emergency operation and maintenance shall be provided aboard ship.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0">18.</entry><entry namest="COLSPEC43" nameend="2" colsep="0" rowsep="0" headers="t5544h1">Testing procedure manuals for remote control and monitoring systems shall be provided aboard ship and the testing procedures shall</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">contain step-by-step or check-off stages and not impair the operation of the installed alarms and safety devices after testing under simulated fault conditions has been completed;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">specify the frequency of testing, indicate the tools required to complete the testing and the location of the tools in the systems; and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5544h0"></entry><entry colsep="0" rowsep="0" headers="t5544h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC42" nameend="2" colsep="0" rowsep="0" headers="t5544h1">be concise but sufficiently explicit to allow engineering personnel to carry out the testing and interpret the results.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division III</Label><TitleText>Group 1 and 2 Ships</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" align="left" htmlwidth="11%" /><colspec colname="COLSPEC44" colwidth="7.55*" htmlwidth="7%" /><colspec colname="2" colwidth="92.49*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5545h0">Item</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5545h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5545h0 t5545h1"><Emphasis style="italic">Machinery</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">1.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">Internal combustion engines of 2250 kW or more or having cylinders of more than 300 mm bore shall be provided with crankcase oil mist detectors, engine-bearing temperature monitors or equivalent devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">2.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">Where internal combustion engines are used for main propulsion, means shall be provided to keep the starting air pressure at the level required to start the engine.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">3.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">The number of consecutive automatic attempts that fail to start an engine shall be limited in order to safeguard sufficient starting air pressure and an audible alarm set at a level that permits starting of the propulsion machinery shall be provided to indicate low starting air pressure.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">4.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">The main source of electrical power shall meet the following requirements:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0"></entry><entry colsep="0" rowsep="0" headers="t5545h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5545h1">where the electrical power can under normal conditions be supplied by one generator, suitable load-shedding arrangements shall be provided to safeguard the supplies of power needed by propulsion, steering and safety systems; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0"></entry><entry colsep="0" rowsep="0" headers="t5545h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5545h1">except where impracticable for ships of less than 1,600 tons gross tonnage, in the case of failure of the operating generator, adequate provision shall be made for automatic starting and connecting to the main switchboard of a stand-by generator of sufficient capacity to permit, in sequential operation where necessary, automatic restarting of the essential propulsion, steering and safety systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">5.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">Where electrical power is supplied simultaneously by more than one generator in parallel operation, provision shall be made in case of failure of one of the operating generator sets to keep the remaining generator sets in operation without overload to permit propulsion and steering, and to ensure the safety of the ship.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">6.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">Where stand-by machines are necessary for the operation of other auxiliary machinery essential to propulsion, automatic change-over devices shall be fitted.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5545h0 t5545h1"><Emphasis style="italic">Controls and Alarms</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">7.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">Under all operating conditions the speed, direction of thrust and, where applicable, the pitch of the propeller shall be fully controllable by remote control from the bridge.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">8.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">The remote control shall be operated by a single control device for each independent propeller with automatic performance of all associated services without causing overload of the propulsion machinery.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">9.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">The main propulsion machinery shall be equipped with an emergency stopping device on the bridge that is independent of the bridge control system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">10.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">The control system shall be such that the services needed for the operation of the main propulsion machinery and its auxiliaries are performed automatically.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">11.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">An audible and visual alarm shall be activated when the automatic change-over of the control power source is activated.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">12.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">An alarm system that meets the requirements of items 7 to 9 of Division II shall be provided for all pressures, temperatures, fluid levels and other data essential to the safe operation of the ship.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">13.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">A centralized control location shall be arranged with the necessary alarm panels and instrumentation to indicate that an alarm has been activated.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">14.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">Remote control of the propulsion machinery shall be possible only from one location at a time and inter-connected control positions are permitted at each location.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">15.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">At each location there shall be an indicator showing which location is in control of the propulsion machinery and the transfer of control between the bridge and machinery spaces shall be possible only in the main machinery space or in the machinery control room.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">16.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">The control system shall include means to prevent, when the system transfers control from one location to another, the propelling thrust from altering to the extent that control of the ship is endangered.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">17.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">All machinery essential for the safe operation of the ship shall be capable of being controlled locally.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">18.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">The design of the remote automatic control system shall be such that an alarm is given on failure of the system and, unless impracticable, the preset speed and direction of thrust of the propeller is maintained until local control is in operation.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">19.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">Indicators shall be fitted on the bridge for</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0"></entry><entry colsep="0" rowsep="0" headers="t5545h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5545h1">propeller speed and direction of rotation in the case of fixed-pitch propellers; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0"></entry><entry colsep="0" rowsep="0" headers="t5545h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5545h1">propeller speed and pitch position in the case of controllable-pitch propellers.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">20.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">Bilge wells in periodically unattended machinery spaces shall be located and monitored in such a way that the accumulation of liquids is detected at normal angles of trim and heel, and shall be large enough to easily accommodate normal drainage during an unattended period.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">21.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">Where the bilge pumps are capable of being started automatically, visual and audible alarms shall be provided to indicate when the influx of liquid is greater than the pump capacity or when the pump is operating more frequently than would be expected under normal conditions.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">22.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">Where automatic bilge pumps are fitted,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0"></entry><entry colsep="0" rowsep="0" headers="t5545h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5545h1">an audible and visual alarm and shut-down arrangement shall be fitted in the system to operate in the event of oil being detected and the shut-down arrangement shall have an emergency manual override capability; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0"></entry><entry colsep="0" rowsep="0" headers="t5545h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5545h1">valves that are open on dry bilges shall be automatically closed so that there is no loss of suction in bilge suction systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">23.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">The position of the controls of any valve serving a sea inlet, a discharge below the water-line or a bilge injection system shall be located to allow adequate time for operation of the controls in case of an influx of water to the space, having regard to the time likely to be required to reach and operate the controls.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5545h0">24.</entry><entry namest="COLSPEC44" nameend="2" colsep="0" rowsep="0" headers="t5545h1">Arrangements shall be made to operate the controls from a position above the level to which the unattended space might become flooded when the ship is fully loaded.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division IV</Label><TitleText>Group 3 Ships</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.67*" align="left" htmlwidth="11%" /><colspec colname="2" colwidth="89.33*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5546h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5546h1">Application</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5546h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5546h1">In this Division, the bridge control station includes the wheelhouse, its top and wings.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="none"><tgroup cols="3"><colspec colname="1" colwidth="11.86*" align="left" htmlwidth="11%" /><colspec colname="COLSPEC45" colwidth="7.57*" htmlwidth="7%" /><colspec colname="2" colwidth="92.50*" htmlwidth="83%" /><thead><row bottommarginspacing="4"><entry colsep="0" id="t5547h0"></entry><entry colsep="0" id="t5547h1"></entry><entry colsep="0" id="t5547h2"></entry></row><row topdouble="yes" bottommarginspacing="4"><entry colsep="0" rowsep="1" id="t5547h3">Item</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="1" id="t5547h4">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Emphasis style="italic">Main and Auxiliary Machinery Controls</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">1.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Control locations shall have a visual indicator to show when they are in command and the central control location shall have monitors and alarms in accordance with items 65 and 66.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">2.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">The machinery control arrangement shall be such that only one location can be in control at any one time, and with the exception of the override capability referred to in item 8, transfer of control from the central control location to local control shall not be possible until the receiving location has indicated its readiness to accept the intended transfer.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">3.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">All essential machinery shall be capable of being fully operated locally when remote or automatic control systems are not operating.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">4.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Transfer to local control of machinery shall be easily and rapidly accomplished and any material or tools required to effect the transfer shall be permanently located at a convenient location adjacent to the machinery.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">5.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where an engine is arranged to start automatically or by remote control, interlocks shall be provided to prevent starting of the engine under conditions that could be hazardous to the machinery, which conditions shall include turning gear engaged, low lubricating-oil pressure and, where applicable, shaft brake engaged.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">6.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where an internal combustion engine is arranged to start automatically, the number of consecutive automatic attempts to start the engine without success shall be limited in order to safeguard sufficient starting air pressure or in the case of electric starting, sufficient battery power, for local attempts to start the engine.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Emphasis style="italic">Main Propulsion Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">7.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Means shall be provided at the central control location and locally at the engines themselves to stop the main propulsion engines in an emergency and the emergency stopping devices shall be independent of the normal control system and adequately protected against accidental damage or operation.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">8.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Local control of the main propulsion engines shall have capability of overriding the remote control systems and there shall be an audible and visual alarm to alert the locations affected by an override in accordance with subitem 65(<Emphasis style="italic">a</Emphasis>)(i).</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">9.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">For ships of not more than 150 tons gross tonnage remote propulsion engine controls are not required to be power-operated and are not required to be in duplicate.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">10.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Prolonged running of a main propulsion engine in a restricted speed range shall be prevented automatically or an indication of restricted speed ranges shall be posted at each control location.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Emphasis style="italic">Steering Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">11.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">In the event of failure of the main steering system there shall be an auxiliary system capable of being brought into operation from the central control location within 45 seconds.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Emphasis style="italic">Electrical Power Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">12.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">In the event of failure of the electrical generator supplying ship service power where generated electrical energy is required for essential service, there shall be a stand-by generator capable of assuming all essential electrical load and, for ships in excess of 150 tons gross tonnage, the stand-by generator shall be arranged to assume the load automatically within 45 seconds.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Emphasis style="italic">Boilers and Hot-Air Heating Units</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">13.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Steam and hot-water boilers, hot-air heating units and associated systems shall be capable of automatic operation and of meeting requirements within design limitations under all working conditions.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">14.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Automatic operation shall include, as applicable, controls and monitors for fuel flow and temperature, combustion air flow, burner flame, feed-water flow, feed-water contamination by salt or oil, boiler pressure and hot-air heating unit circulating air flow.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">15.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">The control and monitoring equipment shall be designed to prevent unsafe operation of the boiler or hot-air heating unit.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">16.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Any failure of control and monitoring equipment shall prevent continued operation of the boiler or hot-air heating unit and cause the fuel supply to be cut off and an audible and visual alarm to be activated in accordance with subitem 65(<Emphasis style="italic">e</Emphasis>).</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">17.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">A master fuel oil shut-off valve shall be fitted in the fuel supply line and shall close automatically in the event of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5547h4">loss of flame;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5547h4">inadequate air to support combustion;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5547h4">abnormally high steam or water pressure in boilers;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5547h4">loss of circulating fluid in hot-water boilers and hot-air heating units; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">e</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5547h4">water at a low level in steam boilers.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">18.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">A fuel oil shut-off valve shall be fitted to each burner in the fuel supply line and the valve shall close automatically in the case of flame failure or whenever the automatic program requires that the master fuel oil shut-off valve be closed.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">19.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Automatic combustion controls shall be fitted to provide an adequate fuel-to-air ratio throughout the operational range.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">20.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where the system is designed to light the initial burner automatically or from a remote location, purging of the combustion chamber and convection spaces shall automatically take place for a period that is sufficient to ensure at least four changes of air, which period shall last at least 15 seconds.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">21.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Adequate air flow and the correct position of the air registers and dampers shall be indicated before the purging period starts.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">22.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Fuel oil may be ignited by an electrical spark generated by a transformer having an output of not less than 10,000 volts, a glow plug or a light-oil pilot flame that has been electrically ignited.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">23.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">A means of ignition system described in item 22 shall be provided for burners that are automatically or remote controlled.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">24.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">The electrical ignition system shall be energized before or simultaneously with the introduction of fuel or light oil and shall remain energized during the trial-for-ignition period referred to in item 25.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">25.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where fuel or light oil is electrically ignited, the flame safeguard control system shall provide a trial-for-ignition period of not more than 15 seconds, during which fuel or light oil may be introduced to the ignition source and, if a flame is not established within 15 seconds, the oil supply valve shall close automatically.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">26.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where fuel oil is ignited by a light-oil pilot flame, the flame safeguard control shall provide a trial-for-ignition period of not more than 15 seconds, during which fuel oil may be introduced to the pilot flame and if a fuel oil flame is not established within 15 seconds the fuel oil supply valve to the pilot flame shall close automatically.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">27.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Fuel oil shall not be supplied to a burner before the light-oil pilot flame has been confirmed.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">28.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Flame safeguard controls of the thermostatic type operated by means of an open bi-metallic helix shall not be used.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">29.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">A flame safeguard control shall be provided to each burner so that the fuel oil supply valve can be closed in not more than four seconds in the event of flame failure and the master fuel oil shut-off valve can be closed in the event of flame failure at all burners.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">30.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">The failure of a component in the flame safeguard control shall cause a shut-down of the burner and the design of the control shall prevent automatic restarting.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">31.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">The flame safeguard control shall be fitted with an audible and visual alarm in the event of flame failure and the control shall require resetting for restart purposes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">32.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">A low-fire interlock shall be fitted to a multi-burner boiler so that the lowest burner is ignited first, and the other burners shall not be ignited until the scanner indicates that there is a flame in the lowest burner.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Emphasis style="italic">Steam Boilers</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">33.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Automatically operated steam boilers shall be fitted with water-level controls and low water-level limit controls.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">34.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Water-level controls and low water-level limit controls may be of the float, electrode probe, thermostatic expansion tube or thermo-hydraulic type.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">35.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Water-level controls and low water-level limit controls shall be located to minimize the effect of the roll and pitch of the ship.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">36.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">The low water-level limit control shall close the master fuel oil shut-off valve when the water level falls to a minimum safe level visible in the gauge glass and the system may include a five-second time delay to avoid shut-down due to the rolling and pitching of the ship.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">37.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">After operation of the low water-level limit control, manual resetting of the control shall be required before the boiler burners can be re-lit.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">38.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Float-operated water-level and low water-level limit controls shall be so constructed that they will not be damaged by water levels above or below the operating range.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">39.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">The low water-level limit control shall have independent connections to the boiler.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">40.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Water-level controls shall be so constructed that the water inlet valve cannot feed water into the boiler through the float chamber.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">41.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">No outlet connection shall be placed on</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5547h4">the water-level control float chamber;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5547h4">the low water-level limit control float chamber; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5547h4">pipes connecting the float chambers to the boiler.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">42.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">For controls that are external to the boiler drum, the connections shall be fitted with shut-off valves locked and sealed in the open position and attached directly to the boiler drum.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Emphasis style="italic">Auxiliary Systems</Emphasis></entry></row><row topmarginspacing="6"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">43.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Subject to item 44, pumps and other components essential for main propulsion engine operation shall have stand-by pumps and components, and for ships of more than 150 tons gross tonnage, the stand-by pumps and components shall be arranged to start up automatically on failure of the operating pumps or other components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">44.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">In multi-engined ships where engines have integral pumps, a spare pump readily available for installation may be used in lieu of an automatic-starting stand-by pump.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">45.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Air compressors, refrigeration systems and other ship service systems that are essentially independent and self-controlled need not be controlled from a remote control location.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">46.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Bilge water high-level audible and visual alarms shall be fitted at the central control location in accordance with subitem 65(<Emphasis style="italic">f</Emphasis>)(vi) and shall monitor the following bilges:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5547h4">aft port and starboard sides of each machinery space of category A; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5547h4">any bilge aft of the collision bulkhead on ships certificated for towing operations.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">47.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">The bilge pumping systems shall be arranged to function for a reasonable period after the sounding of the bilge high-level alarm taking into account the size of the space bilges.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">48.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where automatic bilge pumps are fitted</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5547h4">an audible and visual alarm and shut-down arrangements shall be fitted in the system to operate in the event of oil being detected and the shut-down arrangement shall have an emergency manual override capability; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5547h4">valves that are open on dry bilges shall be automatically closed so that there is no loss of suction in bilge systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">49.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Subject to item 50, the fire control system shall incorporate at least one fire pump capable of being controlled from the fire control location set out in subitem 14(<Emphasis style="italic">e</Emphasis>) of Division II.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">50.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">For ships of 150 tons gross tonnage or less a manual fire pump and its controls, including means of opening the sea valve, may be installed in a suitable location on the deck in lieu of a remote-controlled pump.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">51.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where valves in essential systems are normally closed to prevent frost damage to exposed piping, the controls for the valves shall be in readily accessible locations.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">52.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where remote controls for valves are fitted, valve status indicators shall be fitted at the locations for the valve controls and valves located in locations liable to be flooded shall be capable of operating when submerged.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">53.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where machinery space watertight doors are fitted, controls shall be fitted in accordance with the <XRefExternal reference-type="regulation" link="C.R.C.,_c._1431">Hull Construction Regulations</XRefExternal>.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">54.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Fuel oil service tanks shall be capable of holding sufficient fuel for the total period of the normal ship operational route or for 24 hours normal operation, whichever is the lesser, at full power, except that where provision is made for automatic filling, the period may be reduced to eight hours.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">55.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where fuel tanks are required to be heated, fuel oil temperature shall be monitored and thermostatically controlled or fitted with a high-temperature audible and visual alarm in accordance with subitem 65(<Emphasis style="italic">f</Emphasis>)(iii).</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Emphasis style="italic">Remote Monitors</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">56.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">The central control location shall include monitoring indicators as set out in items 65 and 66.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">57.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where continuously reading indicators are impracticable, demand display types may be fitted.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">58.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Direct reading indicators shall be fitted at the location of the machinery.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">59.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where the control system automatically shuts down machinery for any reason, regaining of control following correction of the fault shall not be possible without reset action and without bringing the control to the stop position.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">60.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Alarms associated with machinery control and safety shall be clearly distinguishable from fire-alarms and, where possible, the arrangements of the alarms shall be such that the alarm is activated before failure and shut-down occurs.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">61.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where alarms are displayed as group alarms, provision shall be made to identify each alarm at the central control location.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">62.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">For the detection of transient faults that are subsequently self-correcting, alarms shall lock in until they are accepted.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">63.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">The alarm system shall be capable of being tested during normal machinery operation.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">64.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Disconnection or manual overriding of any part of the alarm system shall be clearly indicated.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Emphasis style="italic">Remote Monitoring Indicators</Emphasis></entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5547h3">65.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Where applicable and subject to item 66, the following monitors and audible and visual alarms shall be fitted at the central control location:</entry></row><row bottommarginspacing="2"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Provision><TableGroup pointsize="10" topmarginspacing="4"><table frame="none"><tgroup cols="5"><colspec colname="1" colwidth="7.04*" htmlwidth="7%" /><colspec colname="2" colwidth="24.78*" htmlwidth="25%" /><colspec colname="3" colwidth="10.51*" htmlwidth="11%" /><colspec colname="4" colwidth="27.90*" htmlwidth="28%" /><colspec colname="5" colwidth="29.66*" htmlwidth="30%" /><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0">SERVICE</entry><entry namest="3" nameend="4" colsep="0" rowsep="0">MONITOR</entry><entry colsep="0" rowsep="0">ALARM</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top">(<Emphasis style="italic">a</Emphasis>)</entry><entry morerows="2" colsep="0" rowsep="0" valign="top">Main Propulsion System</entry><entry colname="3" colsep="0" rowsep="0" valign="top">(i)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">In Command</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">Local Override</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(ii)</entry><entry colsep="0" rowsep="0">Propeller Speed</entry><entry colsep="0" rowsep="0" valign="bottom">—</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(iii)</entry><entry colsep="0" rowsep="0">Ahead/Astern</entry><entry colsep="0" rowsep="0" valign="bottom">Wrong Direction</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(iv)</entry><entry colsep="0" rowsep="0">Engine Speed</entry><entry colsep="0" rowsep="0" valign="bottom">Failure/Overspeed</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(v)</entry><entry colsep="0" rowsep="0">Exhaust Gas Temperature</entry><entry colsep="0" rowsep="0" valign="bottom">High</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(vi)</entry><entry colsep="0" rowsep="0">Lubricating Oil Pressure</entry><entry colsep="0" rowsep="0" valign="bottom">Low</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(vii)</entry><entry colsep="0" rowsep="0">Lubricating Oil Temperature</entry><entry colsep="0" rowsep="0" valign="bottom">High</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(viii)</entry><entry colsep="0" rowsep="0">Coolant Pressure</entry><entry colsep="0" rowsep="0" valign="bottom">Low</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(ix)</entry><entry colsep="0" rowsep="0">Coolant Temperature</entry><entry colsep="0" rowsep="0" valign="bottom">High</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(x)</entry><entry colsep="0" rowsep="0">Piston Coolant Temperature (if separate system)</entry><entry colsep="0" rowsep="0" valign="bottom">High</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(xi)</entry><entry colsep="0" rowsep="0">Thrust Block Temperature</entry><entry colsep="0" rowsep="0" valign="bottom">High</entry></row></tbody></tgroup></table></TableGroup></Provision></entry></row><row bottommarginspacing="2"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Provision><TableGroup pointsize="10" topmarginspacing="4"><table frame="none"><tgroup cols="5"><colspec colname="1" colwidth="7.04*" htmlwidth="7%" /><colspec colname="2" colwidth="24.78*" htmlwidth="25%" /><colspec colname="3" colwidth="10.51*" htmlwidth="11%" /><colspec colname="4" colwidth="27.90*" htmlwidth="28%" /><colspec colname="5" colwidth="29.66*" htmlwidth="30%" /><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" valign="top">Steering System</entry><entry colname="3" colsep="0" rowsep="0" valign="top">(i)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Steering Gear Power Unit, Operating</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">Failure/Overload</entry></row></tbody></tgroup></table></TableGroup></Provision></entry></row><row bottommarginspacing="2"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Provision><TableGroup pointsize="10" topmarginspacing="4"><table frame="none"><tgroup cols="5"><colspec colname="1" colwidth="7.04*" htmlwidth="7%" /><colspec colname="2" colwidth="24.78*" htmlwidth="25%" /><colspec colname="3" colwidth="10.51*" htmlwidth="11%" /><colspec colname="4" colwidth="27.90*" htmlwidth="28%" /><colspec colname="5" colwidth="29.66*" htmlwidth="30%" /><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top">(<Emphasis style="italic">c</Emphasis>)</entry><entry morerows="2" colsep="0" rowsep="0" valign="top">Electrical System</entry><entry colname="3" colsep="0" rowsep="0" valign="top">(i)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Voltage</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">High/Low</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top"></entry><entry colname="3" colsep="0" rowsep="0" valign="top">(ii)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Frequency</entry><entry colname="5" colsep="0" rowsep="0" valign="top">Low</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top"></entry><entry colname="3" colsep="0" rowsep="0" valign="top">(iii)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Load</entry><entry colname="5" colsep="0" rowsep="0" valign="top">Load Shedding</entry></row></tbody></tgroup></table></TableGroup></Provision></entry></row><row bottommarginspacing="2"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Provision><TableGroup pointsize="10" topmarginspacing="4"><table frame="none"><tgroup cols="5"><colspec colname="1" colwidth="7.04*" htmlwidth="7%" /><colspec colname="2" colwidth="24.78*" htmlwidth="25%" /><colspec colname="3" colwidth="10.51*" htmlwidth="11%" /><colspec colname="4" colwidth="27.90*" htmlwidth="28%" /><colspec colname="5" colwidth="29.66*" htmlwidth="30%" /><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top">(<Emphasis style="italic">d</Emphasis>)</entry><entry morerows="2" colsep="0" rowsep="0" valign="top">Ship Service Generator Engines</entry><entry colname="3" colsep="0" rowsep="0" valign="top">(i)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Engine, Operating</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">—</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top"></entry><entry colname="3" colsep="0" rowsep="0" valign="top">(ii)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Engine Speed</entry><entry colname="5" colsep="0" rowsep="0" valign="top">Failure/Overspeed</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top"></entry><entry colname="3" colsep="0" rowsep="0" valign="top">(iii)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Exhaust Gas Temperature</entry><entry colname="5" colsep="0" rowsep="0" valign="top">High</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(iv)</entry><entry colsep="0" rowsep="0">Lubricating Oil Pressure</entry><entry colsep="0" rowsep="0">Low</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(v)</entry><entry colsep="0" rowsep="0">Lubricating Oil Temperature</entry><entry colsep="0" rowsep="0">High</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(vi)</entry><entry colsep="0" rowsep="0">Coolant Pressure</entry><entry colsep="0" rowsep="0">Low</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(vii)</entry><entry colsep="0" rowsep="0">Coolant Temperature</entry><entry colsep="0" rowsep="0">High</entry></row></tbody></tgroup></table></TableGroup></Provision></entry></row><row bottommarginspacing="2"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Provision><TableGroup pointsize="10" topmarginspacing="4"><table frame="none"><tgroup cols="5"><colspec colname="1" colwidth="7.04*" htmlwidth="7%" /><colspec colname="2" colwidth="24.78*" htmlwidth="25%" /><colspec colname="3" colwidth="10.51*" htmlwidth="11%" /><colspec colname="4" colwidth="27.90*" htmlwidth="28%" /><colspec colname="5" colwidth="29.66*" htmlwidth="30%" /><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top">(<Emphasis style="italic">e</Emphasis>)</entry><entry morerows="2" colsep="0" rowsep="0" valign="top">Boilers and Hot-Air Heating Units</entry><entry colname="3" colsep="0" rowsep="0" valign="top">(i)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Boiler or Hot-Air Heating Unit, Operating</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">Shut-down</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top"></entry><entry colname="3" colsep="0" rowsep="0" valign="top">(ii)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Boiler Fluid Pressure</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">High/Low</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top"></entry><entry colname="3" colsep="0" rowsep="0" valign="top">(iii)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Steam Boiler Water Level</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">High/Low</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(iv)</entry><entry colsep="0" rowsep="0">Feed-Water Pressure</entry><entry colsep="0" rowsep="0" valign="bottom">High/Low</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(v)</entry><entry colsep="0" rowsep="0">Feed-Water Salinity</entry><entry colsep="0" rowsep="0" valign="bottom">High</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(vi)</entry><entry colsep="0" rowsep="0">Feed-Water Oil Contamination</entry><entry colsep="0" rowsep="0" valign="bottom">Detection</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(vii)</entry><entry colsep="0" rowsep="0">Combustion Air Pressure</entry><entry colsep="0" rowsep="0" valign="bottom">Low</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(viii)</entry><entry colsep="0" rowsep="0">Fuel Oil Pressure</entry><entry colsep="0" rowsep="0" valign="bottom">Low</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(ix)</entry><entry colsep="0" rowsep="0">Fuel Oil Temperature</entry><entry colsep="0" rowsep="0" valign="bottom">High/Low</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(x)</entry><entry colsep="0" rowsep="0">Each Furnace Burner Flame</entry><entry colsep="0" rowsep="0" valign="bottom">Failure</entry></row></tbody></tgroup></table></TableGroup></Provision></entry></row><row bottommarginspacing="2"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Provision><TableGroup pointsize="10" topmarginspacing="4"><table frame="none"><tgroup cols="5"><colspec colname="1" colwidth="7.04*" htmlwidth="7%" /><colspec colname="2" colwidth="24.78*" htmlwidth="25%" /><colspec colname="3" colwidth="10.51*" htmlwidth="11%" /><colspec colname="4" colwidth="27.90*" htmlwidth="28%" /><colspec colname="5" colwidth="29.66*" htmlwidth="30%" /><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top">(<Emphasis style="italic">f</Emphasis>)</entry><entry morerows="2" colsep="0" rowsep="0" valign="top">Auxiliary Systems</entry><entry colname="3" colsep="0" rowsep="0" valign="top">(i)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Engine Starting Air Pressure</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">High/Low</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top"></entry><entry colname="3" colsep="0" rowsep="0" valign="top">(ii)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Fuel Service Tank Oil Level</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">High/Low</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top"></entry><entry colname="3" colsep="0" rowsep="0" valign="top">(iii)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Fuel Service Tank Oil Temperature, where required</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">High</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(iv)</entry><entry colsep="0" rowsep="0">Coolant Expansion Tank Liquid Level</entry><entry colsep="0" rowsep="0" valign="bottom">Low</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(v)</entry><entry colsep="0" rowsep="0">All Tanks Automatically Filled</entry><entry colsep="0" rowsep="0" valign="bottom">High/Low</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(vi)</entry><entry colsep="0" rowsep="0">Space Bilge Water Level</entry><entry colsep="0" rowsep="0" valign="bottom">High</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(vii)</entry><entry colsep="0" rowsep="0">Bilge Water, where automatically pumped</entry><entry colsep="0" rowsep="0" valign="bottom">Oil Detection</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(viii)</entry><entry colsep="0" rowsep="0">Bilge Pumps Operating</entry><entry colsep="0" rowsep="0" valign="bottom">—</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(ix)</entry><entry colsep="0" rowsep="0">Watertight Doors, open or closed</entry><entry colsep="0" rowsep="0" valign="bottom">—</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(x)</entry><entry colsep="0" rowsep="0">Machinery Spaces Fire</entry><entry colsep="0" rowsep="0" valign="bottom">Detection</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(xi)</entry><entry colsep="0" rowsep="0">Machinery Spaces High Temperature</entry><entry colsep="0" rowsep="0" valign="bottom">Detection</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(xii)</entry><entry colsep="0" rowsep="0">Fire Main Water Pressure, when activated</entry><entry colsep="0" rowsep="0" valign="bottom">Low</entry></row></tbody></tgroup></table></TableGroup></Provision></entry></row><row bottommarginspacing="2"><entry colsep="0" rowsep="0" headers="t5547h3">66.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">For ships of 150 tons gross tonnage and less, only the following monitors and alarms shall be fitted at the bridge control location:</entry></row><row bottommarginspacing="2"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Provision><TableGroup pointsize="10" topmarginspacing="4"><table frame="none"><tgroup cols="5"><colspec colname="1" colwidth="7.10*" htmlwidth="7%" /><colspec colname="2" colwidth="24.70*" htmlwidth="25%" /><colspec colname="3" colwidth="10.56*" htmlwidth="11%" /><colspec colname="4" colwidth="28.04*" htmlwidth="28%" /><colspec colname="5" colwidth="29.55*" htmlwidth="30%" /><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0">SERVICE</entry><entry namest="3" nameend="4" colsep="0" rowsep="0">MONITOR</entry><entry colsep="0" rowsep="0" valign="bottom">ALARM</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" valign="top">Main Propulsion System</entry><entry colname="3" colsep="0" rowsep="0" valign="top">(i)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">In Command</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">Local Override</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(ii)</entry><entry colsep="0" rowsep="0">Propeller Speed</entry><entry colsep="0" rowsep="0" valign="bottom">—</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(iii)</entry><entry colsep="0" rowsep="0">Ahead/Astern</entry><entry colsep="0" rowsep="0" valign="bottom">Wrong Direction</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(iv)</entry><entry colsep="0" rowsep="0">Exhaust Gas Temperature</entry><entry colsep="0" rowsep="0" valign="bottom">High</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(v)</entry><entry colsep="0" rowsep="0">Lubricating Oil Pressure</entry><entry colsep="0" rowsep="0" valign="bottom">Low</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(vi)</entry><entry colsep="0" rowsep="0">Lubricating Oil Temperature, monitor only</entry><entry colsep="0" rowsep="0" valign="bottom">—</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(vii)</entry><entry colsep="0" rowsep="0">Coolant Pressure, monitor only</entry><entry colsep="0" rowsep="0" valign="bottom">—</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(viii)</entry><entry colsep="0" rowsep="0">Coolant Temperature</entry><entry colsep="0" rowsep="0" valign="bottom">High</entry></row><row><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0"></entry><entry colsep="0" rowsep="0">(ix)</entry><entry colsep="0" rowsep="0">Thrust Block Temperature, if independently lubricated</entry><entry colsep="0" rowsep="0" valign="bottom">High</entry></row></tbody></tgroup></table></TableGroup></Provision></entry></row><row bottommarginspacing="2"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Provision><TableGroup pointsize="10" topmarginspacing="4"><table frame="none"><tgroup cols="5"><colspec colname="1" colwidth="7.10*" htmlwidth="7%" /><colspec colname="2" colwidth="24.70*" htmlwidth="25%" /><colspec colname="3" colwidth="10.56*" htmlwidth="11%" /><colspec colname="4" colwidth="28.04*" htmlwidth="28%" /><colspec colname="5" colwidth="29.55*" htmlwidth="30%" /><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" valign="top">Steering System</entry><entry colname="3" colsep="0" rowsep="0" valign="top">(i)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Steering Gear Power Unit, Operating</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">Failure/Overload</entry></row></tbody></tgroup></table></TableGroup></Provision></entry></row><row bottommarginspacing="2"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Provision><TableGroup pointsize="10" topmarginspacing="4"><table frame="none"><tgroup cols="5"><colspec colname="1" colwidth="7.10*" htmlwidth="7%" /><colspec colname="2" colwidth="24.70*" htmlwidth="25%" /><colspec colname="3" colwidth="10.56*" htmlwidth="11%" /><colspec colname="4" colwidth="28.04*" htmlwidth="28%" /><colspec colname="5" colwidth="29.55*" htmlwidth="30%" /><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top">(<Emphasis style="italic">c</Emphasis>)</entry><entry colsep="0" rowsep="0" valign="top">Boilers</entry><entry colname="3" colsep="0" rowsep="0" valign="top">(i)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Boiler, Operating</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">Shut-down</entry></row></tbody></tgroup></table></TableGroup></Provision></entry></row><row bottommarginspacing="2"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Provision><TableGroup pointsize="10" topmarginspacing="4"><table frame="none"><tgroup cols="5"><colspec colname="1" colwidth="7.10*" htmlwidth="7%" /><colspec colname="2" colwidth="24.70*" htmlwidth="25%" /><colspec colname="3" colwidth="10.56*" htmlwidth="11%" /><colspec colname="4" colwidth="28.04*" htmlwidth="28%" /><colspec colname="5" colwidth="29.55*" htmlwidth="30%" /><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top">(<Emphasis style="italic">d</Emphasis>)</entry><entry morerows="2" colsep="0" rowsep="0" valign="top">Auxiliary Systems</entry><entry colname="3" colsep="0" rowsep="0" valign="top">(i)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Engine, Starting Air Pressure</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">High/Low</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top"></entry><entry colname="3" colsep="0" rowsep="0" valign="top">(ii)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Space Bilge Water Level</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">High</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top"></entry><entry colname="3" colsep="0" rowsep="0" valign="top">(iii)</entry><entry colname="4" colsep="0" rowsep="0" valign="top">Machinery Spaces Fire</entry><entry colname="5" colsep="0" rowsep="0" valign="bottom">Detection</entry></row></tbody></tgroup></table></TableGroup></Provision></entry></row><row bottommarginspacing="2"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5547h3 t5547h4"><Emphasis style="italic">Ships Exempted From Carrying Watchkeeping Engineers</Emphasis></entry></row><row bottommarginspacing="2"><entry colsep="0" rowsep="0" headers="t5547h3">67.</entry><entry namest="COLSPEC45" nameend="2" colsep="0" rowsep="0" headers="t5547h4">Ships exempted from carrying watchkeeping engineers under the <XRefExternal reference-type="regulation">Safe Manning Regulations</XRefExternal> where at least one engineer is required to be aboard shall be</entry></row><row bottommarginspacing="2"><entry colsep="0" rowsep="0" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5547h4">powered by reciprocating-type internal combustion engines;</entry></row><row bottommarginspacing="2"><entry colsep="0" rowsep="0" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5547h4">equipped with remote control and monitoring systems that meet the applicable requirements set out in this Schedule;</entry></row><row bottommarginspacing="2"><entry colsep="0" rowsep="0" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4">(<Emphasis style="italic">c</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5547h4">equipped with central control and monitoring systems suitable for operation by the person assigned steering duties; and</entry></row><row bottommarginspacing="2"><entry colsep="0" rowsep="1" headers="t5547h3"></entry><entry colsep="0" rowsep="1" headers="t5547h4">(<Emphasis style="italic">d</Emphasis>)</entry><entry colsep="0" rowsep="1" headers="t5547h4">subject to periodic checks of machinery spaces by a crew member other than the person assigned steering duties.</entry></row><row bottommarginspacing="2"><entry colsep="0" rowsep="0" headers="t5547h3"></entry><entry colsep="0" rowsep="0" headers="t5547h4"></entry><entry colsep="0" rowsep="0" headers="t5547h4"></entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.34*" htmlwidth="10%" /><colspec colname="2" colwidth="89.66*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5558h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5558h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5558h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5558h1">General arrangement of remote control and monitoring systems showing all connected machinery.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5558h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5558h1">General arrangement of control and monitoring systems, including scanning points and control locations for periodically unattended machinery spaces.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5558h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5558h1">General arrangement of remote control console identifying control and monitoring instruments, gauges and alarms.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5558h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5558h1">Details of electric, pneumatic or hydraulic operational control and monitoring systems, and details of emergency operation arrangements for all machinery required for, or which may affect, the operational safety of the ship and safety of personnel on board.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5558h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5558h1">Details of remotely controlled fire detection, alarm and extinguishing systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5558h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5558h1">List of monitor and audio and visual alarm locations and identification of the equipment used and the manufacturer of the equipment.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5558h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5558h1">General arrangement of intercommunication systems linking the bridge, accommodation spaces, service spaces, the central control room and machinery spaces, including the emergency situation alarm for engineers.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5558h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5558h1">List of symbols and abbreviations used in plans in accordance with a recognized and identified code or fully explained in the data supplied.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5558h0">9.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5558h1">Operational, maintenance and testing procedure manuals for control, monitoring, alarm and safety devices including duplicate and emergency arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5558h0">10.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5558h1">Data indicating proposed duration of times in a 24-hour period when machinery spaces of Category A will normally be unoccupied and when other machinery spaces, such as steering gear compartments, will not normally be visited.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5558h0">11.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5558h1">Data indicating surveillance arrangements on Groups 1 and 2 ships when operating in confined waters.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5558h0">12.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5558h1">Data indicating security arrangements to prevent unauthorized actions in periodically unattended machinery spaces.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5559h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5559h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5559h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5559h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division ii</Label><TitleText>Installation Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5560h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5560h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5560h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5560h1">Identification from component inspection certificates before installation is commenced of materials and components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5560h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5560h1">Witnessing of pressure testing of components as required in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5560h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5560h1">Verification of correct adjustment and operational condition of securing arrangements and connection of the remote control and monitoring systems to associated systems.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5560h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5560h1">Witnessing of operational tests of the systems including emergency and simulated fault test arrangements in accordance with rules and codes.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.28*" htmlwidth="10%" /><colspec colname="COLSPEC46" colwidth="7.77*" htmlwidth="7%" /><colspec colname="2" colwidth="91.41*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5561h0">Item</entry><entry namest="COLSPEC46" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5561h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5561h0">1.</entry><entry namest="COLSPEC46" nameend="2" colsep="0" rowsep="0" headers="t5561h1">Inspection of all securing arrangements and points where leakages and excessive vibration may occur at all control locations and at the machinery itself.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5561h0">2.</entry><entry namest="COLSPEC46" nameend="2" colsep="0" rowsep="0" headers="t5561h1">Inspection of connecting systems between control locations and the machinery without complete removal of all protective panels if</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5561h0"></entry><entry colsep="0" rowsep="0" headers="t5561h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5561h1">the condition of exposed systems parts is adequate taking into account normal wear; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5561h0"></entry><entry colsep="0" rowsep="0" headers="t5561h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5561h1">there is no apparent damage to, or deterioration of unexposed parts of the systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5561h0">3.</entry><entry namest="COLSPEC46" nameend="2" colsep="0" rowsep="0" headers="t5561h1">Witnessing of tests including emergency and simulated fault tests to confirm that all control, monitoring, alarm and safety devices are in operational condition and correct adjustment.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5561h0">4.</entry><entry namest="COLSPEC46" nameend="2" colsep="0" rowsep="0" headers="t5561h1">Witnessing of tests to confirm that systems are operable from all control locations and that the machinery is operable locally.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5561h0">5.</entry><entry namest="COLSPEC46" nameend="2" colsep="0" rowsep="0" headers="t5561h1">Witnessing of tests to confirm that duplicate and emergency systems can be rapidly brought into operation on failure of the main system.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><OriginatingRef>(Section 20)</OriginatingRef><TitleText>Periodic Special Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5562h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5562h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5562h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5562h1">Subject to paragraph 20(2)(<Emphasis style="italic">b</Emphasis>) of these Regulations, no periodic special inspection is required.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;9&quot;"><ScheduleFormHeading><Label>SCHEDULE IX</Label><TitleText>NON-STRUCTURAL TANKS, SHORT FLEXIBLE HOSES AND RIGID PLASTIC AND FIBRE-REINFORCED PLASTIC PIPING AND COMPONENTS</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Application</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5563h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5563h1">Application</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5563h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5563h1">This Schedule applies to non-structural tanks having a capacity of 4 500 L or less.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5563h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5563h1">Non-structural tanks having a capacity of more than 4 500 L shall be designed, constructed and installed in accordance with the <XRefExternal reference-type="regulation" link="C.R.C.,_c._1431">Hull Construction Regulations</XRefExternal>.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division ii</Label><TitleText>Specifications</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="12.79*" htmlwidth="10%" /><colspec colname="COLSPEC48" colwidth="9.48*" htmlwidth="8%" /><colspec colname="COLSPEC47" colwidth="9.89*" htmlwidth="8%" /><colspec colname="2" colwidth="91.67*" htmlwidth="74%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5564h0">Item</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5564h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5564h0 t5564h1"><Emphasis style="italic">Non-Structural Tanks of 4 500 L or Less Capacity</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">1.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Non-structural tanks shall</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">be made of steel or other material suitable for the liquid contents, the intended use and location of the tanks in the ship;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">where carbon steel shell plate is used, be of the following minimum plate thickness:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5564h1">2 mm for capacity not exceeding 100 L,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5564h1">3 mm for capacity not exceeding 1 300 L, and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(iii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5564h1">5 mm for capacity not exceeding 4 500 L;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">be fitted with stiffeners so that any unsupported flat surface area does not exceed</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5564h1">0.28 m<Sup>2</Sup> where plate thickness does not exceed 3 mm, and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5564h1">0.56 m<Sup>2</Sup> where plate thickness does not exceed 5 mm;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">be fitted with a suitable clean-out door, where capacity exceeds 1 300 L; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">have welded or brazed seams, except that where the capacity is not more than 100 L, a solder having a melting point of not less than 425°C may be used.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">2.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Unsupported flat surface areas for different thickness plates of non-structural tanks shall be determined by interpolation or extrapolation.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">3.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Depending on the size and configuration of a non-structural tank, the tank may be required to be fitted with baffles.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5564h0 t5564h1"><Emphasis style="italic">Short Flexible Hoses</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">4.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Short flexible hoses shall be used where expansion and vibration may be encountered.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">5.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Short flexible hoses shall not be used in the correction of misalignment, except for connection of boiler fuel burners and other removable components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">6.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Guards shall be fitted on large diameter pipes to reduce the flow of fluid leakage to within the capacity of the space bilge pumps.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">7.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Guards shall be fitted to prevent contact of leaking fluid with surfaces where a hazard may result.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">8.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Short flexible hoses shall be adequate for intended use.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5564h0 t5564h1"><Emphasis style="italic">Rigid Plastic and Fibre Reinforced Plastic Piping and Components</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">9.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Except in accommodation spaces, service spaces and control locations, piping and components of rigid plastic or fibre reinforced plastic may be used in</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">domestic and sanitary</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5564h1">salt water piping systems,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5564h1">fresh water piping systems, and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(iii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5564h1">waste water piping systems;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">scupper systems draining inboard but not led within the boundaries of refrigerated chambers;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">ballast water and fresh water piping systems situated inside tanks used exclusively for ballast water or fresh water;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">sounding and vent pipes to tanks used exclusively for ballast water or fresh water in non-passenger ships except for sections above the weather deck;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">sounding pipes to cargo holds in non-passenger ships; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">f</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">bilge suction pipes in ships not over 24 m in length.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">10.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Piping and components of rigid plastic or reinforced plastic shall not be used</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">in fire extinguishing piping systems;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">in flammable fluid piping systems;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">in boiler feed and condensate piping systems;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">in bilge and ballast piping systems in machinery spaces except as provided for in subitem 9 (<Emphasis style="italic">f</Emphasis>);</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">outboard of sea inlet or overboard discharge valves; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">f</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">in other piping systems where the use could compromise the safety of the ship or personnel.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">11.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Piping and components of rigid plastic or reinforced plastic shall be protected from</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">vibration;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">chafing where secured in hangers; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">crushing due to overtightening of hanger clamps where they shall be protected by fitting nut-locking or other suitable devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">12.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Allowance shall be made for expansion in piping systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">13.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Sea inlet and overboard discharge valves shall be of suitable metal construction where connected to plastic or fibre reinforced plastic piping and the piping shall not be installed outboard of the valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">14.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">When passing through a steel water-tight or fire control bulkhead, a steel spool-piece shall be attached to the bulkhead or deck and, at a water-tight bulkhead or deck a metallic shut-off valve shall be installed immediately adjacent to the spool-piece except that no valve is required on ballast or fresh water piping located within ballast or fresh water tanks.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">15.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">Remote controls operable from above the bulkhead deck shall be fitted to the shut-off valve except where</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">the piping on one side of the bulkhead or deck is completely metallic and the valve is fitted to the metallic piping and easily accessible; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0"></entry><entry colsep="0" rowsep="0" headers="t5564h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC47" nameend="2" colsep="0" rowsep="0" headers="t5564h1">two readily accessible valves are installed, one on either side of the bulkhead or deck.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5564h0">16.</entry><entry namest="COLSPEC48" nameend="2" colsep="0" rowsep="0" headers="t5564h1">When passing through a bulkhead or deck material other than steel, the installation shall be such that the fire, watertight and structural integrity of the bulkhead or deck is not diminished due to penetration.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.84*" htmlwidth="11%" /><colspec colname="COLSPEC49" colwidth="8.30*" htmlwidth="7%" /><colspec colname="2" colwidth="91.78*" htmlwidth="82%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5565h0">Item</entry><entry namest="COLSPEC49" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5565h1">Required Information</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5565h0 t5565h1"><Emphasis style="italic">Non-Structural Tanks of 4 500 L or Less Capacity</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0">1.</entry><entry namest="COLSPEC49" nameend="2" colsep="0" rowsep="0" headers="t5565h1">General arrangement of the tank installation and the system to which it is connected.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0">2.</entry><entry namest="COLSPEC49" nameend="2" colsep="0" rowsep="0" headers="t5565h1">Details of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0"></entry><entry colsep="0" rowsep="0" headers="t5565h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5565h1">nature of the fluid to be contained in the tank;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0"></entry><entry colsep="0" rowsep="0" headers="t5565h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5565h1">tank volume and design fluid head;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0"></entry><entry colsep="0" rowsep="0" headers="t5565h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5565h1">tank materials, sizes, plate seams and supports; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0"></entry><entry colsep="0" rowsep="0" headers="t5565h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5565h1">tank openings, vents and other connections.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0">3.</entry><entry namest="COLSPEC49" nameend="2" colsep="0" rowsep="0" headers="t5565h1">Detailed strength calculations where</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0"></entry><entry colsep="0" rowsep="0" headers="t5565h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5565h1">tank design pressure head exceeds 5 m; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0"></entry><entry colsep="0" rowsep="0" headers="t5565h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5565h1">tank material is other than steel.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5565h0 t5565h1"><Emphasis style="italic">Short Flexible Hoses</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0">4.</entry><entry namest="COLSPEC49" nameend="2" colsep="0" rowsep="0" headers="t5565h1">Material specifications including details of construction and end connection arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0">5.</entry><entry namest="COLSPEC49" nameend="2" colsep="0" rowsep="0" headers="t5565h1">Details of the various tests applied to the hoses and identification of the standards association whose testing standards were applied.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0">6.</entry><entry namest="COLSPEC49" nameend="2" colsep="0" rowsep="0" headers="t5565h1">Details of the design working pressures, temperatures, fluid flow velocities and nature of the fluids to be carried.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5565h0 t5565h1"><Emphasis style="italic">Rigid Plastic and Fibre-Reinforced Plastic Piping and Components</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0">7.</entry><entry namest="COLSPEC49" nameend="2" colsep="0" rowsep="0" headers="t5565h1">Material specifications, physical properties, details of the various tests carried out and identification of the standards association whose testing standards were applied.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0">8.</entry><entry namest="COLSPEC49" nameend="2" colsep="0" rowsep="0" headers="t5565h1">Characteristics of flammability, decomposition resistance to environmental conditions and abrasion resistance to sand, ice particles or other fluid entrained substances.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0">9.</entry><entry namest="COLSPEC49" nameend="2" colsep="0" rowsep="0" headers="t5565h1">Details of connections, scantlings, design working pressures, temperatures and fluid flow velocities.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5565h0">10.</entry><entry namest="COLSPEC49" nameend="2" colsep="0" rowsep="0" headers="t5565h1">Details of piping systems, locations, supports and thermal expansion allowances taking into account differences in the thermal expansion properties of plastic materials and metal.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5566h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5566h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5566h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5566h1">Construction and installation inspections shall consist of completion of each item set out in Part III of Schedules X to XV for the relevant fluid system.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5567h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5567h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5567h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5567h1">Completion of each item set out in Division I of Part IV of Schedules X to XV for the relevant fluid system.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic Special Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5568h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5568h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5568h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5568h1">No periodic special inspection is required if a general examination shows that the condition of the tanks is suitable for further service.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5569h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5569h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5569h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5569h1">None.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;10&quot;"><ScheduleFormHeading><Label>SCHEDULE X</Label><TitleText>STEAM, BOILER WATER AND COOLING WATER SYSTEMS</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.34*" htmlwidth="10%" /><colspec colname="2" colwidth="89.66*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5570h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5570h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5570h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5570h1">Steam pipes and connected components through which steam passes shall be designed, constructed and installed to withstand the maximum working stresses to which they may be subjected.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5570h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5570h1">Means shall be provided for draining every steam pipe in which dangerous water-hammer action may occur.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5570h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5570h1">Where a steam pipe or component may receive steam from any source at a higher pressure than that for which it is designed, it shall be fitted with a suitable reducing valve, relief valve and pressure gauge.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5570h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5570h1">Each steam generating system that provides services essential for the safety of the ship, or that could be rendered dangerous by the failure of its feed-water supply shall be fitted with at least two separate feed- water systems, including feed pumps, but a single penetration of the steam drum is acceptable.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5570h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5570h1">Unless over-pressure is prevented by the pump characteristics, means shall be provided to prevent over-pressure in any part of the system.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.28*" htmlwidth="10%" /><colspec colname="COLSPEC50" colwidth="7.65*" htmlwidth="7%" /><colspec colname="2" colwidth="91.53*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5571h0">Item</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5571h1">Required Information</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5571h0 t5571h1"><Emphasis style="italic">Steam and Exhaust Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">1.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">General arrangement of the steam systems having an assigned working pressure in excess of 103 kPa including steam power, steam heating, steam cleaning and steam fire-extinguishing systems showing all connected pressure vessels, pumps, shut-off valves, piping, steam traps, reducing valves, safety valves, pressure gauges and drainage arrangements, particularly where the systems are susceptible to frost or water-hammer damage.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">2.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">General arrangement of exhaust steam piping from machinery or other components powered or heated by steam systems referred to in item 1 showing arrangements for further use, condensing or atmospheric discharge.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">3.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Installation details of items 1 and 2 stating assigned working pressures, temperatures and flow rates.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">4.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Materials, sizes, capacities, design working pressures, temperatures, testing arrangements and procedures of pumps, piping, valves and other components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">5.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Details of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">pipe connections to flanges and other joining arrangements;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">securing arrangements for pumps and piping, allowances for vibration and thermal expansion and stress calculations where required;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">protection against piping damage particularly where led through working spaces;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">materials, means of attachment and thickness of thermal insulation; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">protection against overpressure to or from steam systems when used for heating purposes in integral jackets of machinery.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">6.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Information for valves and similar minor fittings referred to in item 4 is not required to be submitted where a manufacturer or an approved classification society certifies that the types of valves or similar minor fittings have been designed and constructed in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">7.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Information for pumps referred to in item 4 is not required to be submitted where an approved classification society certifies that the pumps have been designed and constructed in accordance with rules or codes except that the driving motor or engine of the pumps shall meet the requirements of Part II of the applicable schedule of Schedules I to XV.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5571h0 t5571h1"><Emphasis style="italic">Condensate and Boiler Feed Water Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">8.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">General arrangement of condensate and reserve boiler feed water systems including reserve feed tank and observation tank connections, pumps, piping, valves, and all connected components and means for</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">carrying out water purity tests;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">dealing with contaminated water; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">draining systems that are susceptible to frost damage.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">9.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">General arrangement of boiler feed, blow down and surface blow piping indicating all connected pumps, valves, components and shipside connections.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">10.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Structural details of tanks that do not form part of the hull structure.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">11.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Installation details of items 8 and 9 stating assigned working pressures, temperatures and flow rates.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">12.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Materials, sizes, design working pressures, testing arrangements and procedures of pumps, piping, valves and other components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">13.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Details of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">pipe connections to flanges or other joining arrangements;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">securing arrangements for pumps, non-structural tanks, and piping and damage protection where necessary; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">materials, means of attachment and thickness of thermal insulation.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">14.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Information for valves and similar minor components referred to in item 12 is not required to be submitted where a manufacturer or an approved classification society certifies that the types of valves or similar minor components have been designed and constructed in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">15.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Information for pumps referred to in item 12 is not required to be submitted where an approved classification society certifies that the pumps have been designed and constructed in accordance with rules or codes except that the driving motor or engine of the pumps shall meet the requirements of Part II of the applicable schedule of Schedules I to XV.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5571h0 t5571h1"><Emphasis style="italic">Cooling Water Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">16.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">General arrangement of fresh and seawater cooling systems pumps, piping, valves and components including, as applicable, sea suction strainers, air vent piping, sea boxes, internal sea bays, keel coolers, ship structure tank coolers, make-up water tanks and means for draining systems that are susceptible to frost damage.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">17.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Details of sea inlet and discharge arrangements including arrangements to ensure that no above waterline discharges are in the way of lifeboat and liferaft lowering locations and, where applicable, piping arrangements for internal sea bays, keel coolers and ship structure tank coolers.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">18.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Structural details of tanks not forming part of the hull structure.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">19.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Installation details of all water systems referred to in item 16 stating assigned working pressures, temperatures and flow rates.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">20.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Materials, sizes, design working pressures, testing arrangements and procedures of pumps, piping, valves and other components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">21.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Details of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">pipe connections to flanges or other joining arrangements;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">securing arrangements for pumps, non-structural tanks and piping; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0"></entry><entry colsep="0" rowsep="0" headers="t5571h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5571h1">protection against overpressure to or from water systems when used for cooling purposes in integral jackets of machinery.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">22.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Information for valves and similar minor components referred to in item 20 is not required to be submitted where a manufacturer or an approved classification society certifies that the types of valves or similar minor components have been designed and constructed in accordance with rules or codes.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5571h0">23.</entry><entry namest="COLSPEC50" nameend="2" colsep="0" rowsep="0" headers="t5571h1">Information for pumps referred to in item 20 is not required to be submitted where an approved classification society certifies that the pumps have been designed and constructed in accordance with rules or codes except that the driving motor or engine of the pumps shall meet the requirements of Part II of the applicable schedule of Schedules I to XV.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5572h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5572h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5572h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5572h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Installation Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.24*" htmlwidth="10%" /><colspec colname="2" colwidth="89.76*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5573h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5573h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5573h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5573h1">Identification from component inspection certificates, before installation is commenced, of pumps, piping, flexible hoses, components and materials to be used, including welding metal.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5573h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5573h1">Verification that welding was carried out by welders certified by a Provincial Government of Canada, or another authority having similar standards where the welding was carried out outside Canada, for the class of work to be done.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5573h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5573h1">Inspection of welds and verification of the heat treatment process in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5573h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5573h1">Witnessing of hydrostatic pressure tests in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5573h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5573h1">Inspection of securing arrangements, connections with associated systems and verification of correct adjustment and operational condition of safety, control and monitoring devices.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5573h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5573h1">Witnessing of operational tests of the system in accordance with rules or codes.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.28*" htmlwidth="10%" /><colspec colname="COLSPEC51" colwidth="7.77*" htmlwidth="7%" /><colspec colname="2" colwidth="91.41*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5574h0">Item</entry><entry namest="COLSPEC51" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5574h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5574h0">1.</entry><entry namest="COLSPEC51" nameend="2" colsep="0" rowsep="0" headers="t5574h1">For steam and exhaust systems, where applicable and, in the opinion of the inspector, practicable,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5574h0"></entry><entry colsep="0" rowsep="0" headers="t5574h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5574h1">inspection of securing arrangements and of locations where fluid leakage and excessive vibration may occur; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5574h0"></entry><entry colsep="0" rowsep="0" headers="t5574h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5574h1">verification of correct adjustment and operational condition of reducing valves, safety valves and associated pressure gauges.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5574h0">2.</entry><entry namest="COLSPEC51" nameend="2" colsep="0" rowsep="0" headers="t5574h1">For boiler water and cooling water systems, where applicable and, in the opinion of the inspector, practicable,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5574h0"></entry><entry colsep="0" rowsep="0" headers="t5574h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5574h1">inspection of securing arrangements, of locations where fluid leakage may occur and of sea inlet and discharge connections; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5574h0"></entry><entry colsep="0" rowsep="0" headers="t5574h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5574h1">verification of correct adjustment and operational condition of valves and components within the systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5574h0">3.</entry><entry namest="COLSPEC51" nameend="2" colsep="0" rowsep="0" headers="t5574h1">For pumps, where applicable and, in the opinion of the inspector, practicable,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5574h0"></entry><entry colsep="0" rowsep="0" headers="t5574h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5574h1">verification that the pumps are operational and in correct adjustment; and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5574h0"></entry><entry colsep="0" rowsep="0" headers="t5574h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5574h1">verification that all control, monitoring, alarm and safety devices are operational and in correct adjustment.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic General Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.85*" htmlwidth="11%" /><colspec colname="COLSPEC52" colwidth="7.45*" htmlwidth="7%" /><colspec colname="2" colwidth="92.62*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5575h0">Item</entry><entry namest="COLSPEC52" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5575h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0">1.</entry><entry namest="COLSPEC52" nameend="2" colsep="0" rowsep="0" headers="t5575h1">Except as prescribed in Schedules I to III, safety valves, pressure gauges and other components in steam, boiler water and cooling water systems and reducing valves in steam systems are to be inspected without opening up unless considered necessary by the inspector on the basis of the general condition of the steam, boiler water and cooling water systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0">2.</entry><entry namest="COLSPEC52" nameend="2" colsep="0" rowsep="0" headers="t5575h1">Subject to items 3 to 6, steam piping systems that have an external diameter in excess of 75 mm shall have selected pipes removed for</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0"></entry><entry colsep="0" rowsep="0" headers="t5575h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5575h1">external inspection of flange connections;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0"></entry><entry colsep="0" rowsep="0" headers="t5575h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5575h1">internal inspection as far as practicable; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0"></entry><entry colsep="0" rowsep="0" headers="t5575h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5575h1">hydrostatic pressure testing to 1.5 times the assigned working pressure.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0">3.</entry><entry namest="COLSPEC52" nameend="2" colsep="0" rowsep="0" headers="t5575h1">Pipes selected for inspection shall be different from the pipes selected during the previous inspection so that in the course of successive inspections all pipes of the system are inspected and tested.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0">4.</entry><entry namest="COLSPEC52" nameend="2" colsep="0" rowsep="0" headers="t5575h1">Steam piping that has an external diameter in excess of 75 mm and that has welded joints between lengths of pipe or between pipes and valves shall have</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0"></entry><entry colsep="0" rowsep="0" headers="t5575h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5575h1">the insulation that is in the way of welds removed;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0"></entry><entry colsep="0" rowsep="0" headers="t5575h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5575h1">the piping hydrostatically pressure tested to 1.5 times the assigned working pressure; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0"></entry><entry colsep="0" rowsep="0" headers="t5575h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5575h1">the joints inspected and where necessary examined by means of a magnetic-particle, dye-penetrant or other crack detection method.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0">5.</entry><entry namest="COLSPEC52" nameend="2" colsep="0" rowsep="0" headers="t5575h1">All copper steam pipes that have an external diameter in excess of 75 mm, shall be subjected to a hydrostatic pressure test of twice the assigned working pressure of the system and all seams, including longitudinal seams where fitted, exposed for inspection.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0">6.</entry><entry namest="COLSPEC52" nameend="2" colsep="0" rowsep="0" headers="t5575h1">Copper steam pipes that have a diameter in excess of 75 mm and that are subject to flexing action through expansion or vibration and copper steam piping immediately adjacent to machinery shall be removed for annealing prior to being hydrostatically pressure tested in accordance with subitem 2(<Emphasis style="italic">c</Emphasis>).</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0">7.</entry><entry namest="COLSPEC52" nameend="2" colsep="0" rowsep="0" headers="t5575h1">For pumps and driving components, where applicable,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0"></entry><entry colsep="0" rowsep="0" headers="t5575h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5575h1">all internal and external parts including valves, bearings and safety devices; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0"></entry><entry colsep="0" rowsep="0" headers="t5575h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5575h1">all securing arrangements without dismantling if a general examination shows that the condition of the components is suitable for further service.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0">8.</entry><entry namest="COLSPEC52" nameend="2" colsep="0" rowsep="0" headers="t5575h1">For shipside sea inlet valves, strainers, overboard discharge valves and valves connected to internal sea bays, keel coolers, reserve feed water tanks and observation tanks,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0"></entry><entry colsep="0" rowsep="0" headers="t5575h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5575h1">internal and external parts; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0"></entry><entry colsep="0" rowsep="0" headers="t5575h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5575h1">all securing arrangements without dismantling if a general examination indicates that the condition of the components is suitable for further service.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5575h0">9.</entry><entry namest="COLSPEC52" nameend="2" colsep="0" rowsep="0" headers="t5575h1">No inspection is required for speed regulating governors and other complex mechanisms where written information is provided to the inspector from firms specializing in the reconditioning of these parts indicating that the parts are in good order and adjustment.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5576h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5576h1">Requirements</entry></row></thead><tbody><row topmarginspacing="4"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5576h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5576h1">Components listed in item 1 of Subdivision I, at intervals not exceeding five years.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5576h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5576h1">Subject to item 3, superheated steam pipes, at intervals not exceeding four years.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5576h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5576h1">Saturated steam pipes and superheated steam pipes that have an external diameter of less than 75 mm and not subject to temperatures exceeding 450°C, eight years after installation and thereafter at intervals not exceeding four years.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5576h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5576h1">Pumps and driving components, at intervals not exceeding five years.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;11&quot;"><ScheduleFormHeading><Label>SCHEDULE XI</Label><TitleText>COMPRESSED AIR AND REFRIGERATING GAS SYSTEMS</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5577h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5577h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5577h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5577h1">Means shall be provided to prevent over-pressure in any part of compressed air and refrigerating gas systems and in water jackets or casings of compressors and coolers that may be subjected to over-pressure due to pressurized air or gas leakage.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5577h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5577h1">Where necessary, engine starting compressed air arrangements shall be adequately protected against the effects of backfiring and internal explosion in the starting air pipes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5577h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5577h1">All discharge pipes from starting air compressors shall lead directly to the starting air receivers, and all starting pipes from the air receivers to main or auxiliary engines shall be entirely separate from the compressor discharge piping system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5577h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5577h1">Means shall be provided to reduce to a minimum the entry of oil into the air pressure systems and to drain those systems.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5577h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5577h1">Where soldering is to be used for piping connections, the metal shall be silver solder.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC53" colwidth="7.31*" htmlwidth="7%" /><colspec colname="2" colwidth="92.74*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5578h0">Item</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5578h1">Required Information</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5578h0 t5578h1"><Emphasis style="italic">Compressed Air Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">1.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">General arrangement of unfired pressure vessels, compressors, air-driven machinery, valves, piping, moisture traps, reducing valves, safety valves, pressure gauges and drainage arrangements, particularly where susceptible to frost damage.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">2.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">Installation details indicating assigned working pressures, temperatures and flow rates.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">3.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">Materials, sizes, capacities, design working pressures, temperatures, testing arrangements and procedures of compressors, air driven machinery, piping, valves and other components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">4.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">Details of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0"></entry><entry colsep="0" rowsep="0" headers="t5578h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5578h1">pipe connections to flanges or other joining arrangements;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0"></entry><entry colsep="0" rowsep="0" headers="t5578h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5578h1">securing arrangements of compressors, air driven machinery, piping and allowances for vibration; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0"></entry><entry colsep="0" rowsep="0" headers="t5578h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5578h1">protection against piping damage and over-pressure to or from cooling fluid in integral jackets.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">5.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">Information set out in items 1 to 4 is not required to be submitted for</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0"></entry><entry colsep="0" rowsep="0" headers="t5578h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5578h1">ships not in excess of 18 m and certificated to carry not more than 12 passengers; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0"></entry><entry colsep="0" rowsep="0" headers="t5578h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5578h1">systems with an assigned working pressure not in excess of 103 kPa.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">6.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">Information for valves and similar minor components referred to in item 3 is not required to be submitted where a manufacturer or an approved classification society certifies that the types of valves or similar minor components have been designed and constructed in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">7.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">Information for compressors or air driven machinery referred to in item 3 is not required to be submitted where an approved classification society certifies that the compressors or air driven machinery have been designed and constructed in accordance with rules or codes except that the driving or driven components shall meet the requirements of Part II of the applicable schedule of Schedules I to XV.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5578h0 t5578h1"><Emphasis style="italic">Refrigerating Gas Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">8.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">General arrangement and location of compressors, valves, driers, strainers, oil separators, safety devices, sight glasses, piping, temperature and pressure gauges, alarms, condensers, liquid receivers, evaporation arrangements, refrigerated and air conditioned spaces.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">9.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">Installation details indicating assigned working pressures, temperatures and capacities.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">10.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">Materials, sizes, capacities, design working pressures, temperatures, testing arrangements and procedures of compressors, piping, valves and other components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">11.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">Details of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0"></entry><entry colsep="0" rowsep="0" headers="t5578h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5578h1">pipe connections to flanges or other joining arrangements;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0"></entry><entry colsep="0" rowsep="0" headers="t5578h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5578h1">securing arrangements of compressors and piping, allowances for vibration, thermal expansion and contraction and insulation;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0"></entry><entry colsep="0" rowsep="0" headers="t5578h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5578h1">protection against piping damage and against over-pressure to crankcases and to or from cooling fluid in integral jackets of machinery; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0"></entry><entry colsep="0" rowsep="0" headers="t5578h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5578h1">ventilating refrigeration machinery spaces and, for ammonia systems, the gas containing and clearing methods.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">12.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">Information set out in items 8 to 11 is not required to be submitted for</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0"></entry><entry colsep="0" rowsep="0" headers="t5578h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5578h1">ships not in excess of 18 m certificated to carry not more than 12 passengers; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0"></entry><entry colsep="0" rowsep="0" headers="t5578h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5578h1">systems where the power absorbed by the gas compressor is not in excess of 10 kW except where the gas is ammonia.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">13.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">Information for valves and similar minor components referred to in item 10 is not required to be submitted where a manufacturer or an approved classification society certifies that the types of valves or similar minor components have been designed and constructed in accordance with rules or codes.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5578h0">14.</entry><entry namest="COLSPEC53" nameend="2" colsep="0" rowsep="0" headers="t5578h1">Information for compressors referred to in item 10 is not required to be submitted where an approved classification society certifies that the compressors have been designed and constructed in accordance with rules or codes except that the driving motors or engines of the compressors shall meet the requirements of Part II of the applicable schedule of Schedules I to XV.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5579h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5579h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5579h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5579h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Installation Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.51*" htmlwidth="10%" /><colspec colname="COLSPEC54" colwidth="7.65*" htmlwidth="7%" /><colspec colname="2" colwidth="91.29*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5580h0">Item</entry><entry namest="COLSPEC54" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5580h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5580h0">1.</entry><entry namest="COLSPEC54" nameend="2" colsep="0" rowsep="0" headers="t5580h1">Identification from component inspection certificates, before installation is commenced, of compressors, piping, flexible hoses, components and materials to be used, including welding or brazing metal.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5580h0">2.</entry><entry namest="COLSPEC54" nameend="2" colsep="0" rowsep="0" headers="t5580h1">Verification that welding was carried out by welders certified by a Provincial Government of Canada, or another authority having similar standards where the welding was carried out outside Canada, for the class of work to be done.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5580h0">3.</entry><entry namest="COLSPEC54" nameend="2" colsep="0" rowsep="0" headers="t5580h1">Inspection of welds.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5580h0">4.</entry><entry namest="COLSPEC54" nameend="2" colsep="0" rowsep="0" headers="t5580h1">Witnessing of hydrostatic pressure tests and for a refrigerating gas system, verification that gas leak testing has been satisfactorily carried out in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5580h0">5.</entry><entry namest="COLSPEC54" nameend="2" colsep="0" rowsep="0" headers="t5580h1">Inspection of securing arrangements of compressors and heat exchangers, connection of piping to associated systems and verification of correct adjustment and operational condition of safety, control and monitoring devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5580h0">6.</entry><entry namest="COLSPEC54" nameend="2" colsep="0" rowsep="0" headers="t5580h1">Witnessing of operational tests of the system in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5580h0">7.</entry><entry namest="COLSPEC54" nameend="2" colsep="0" rowsep="0" headers="t5580h1">Items 1 to 6 do not apply to</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5580h0"></entry><entry colsep="0" rowsep="0" headers="t5580h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5580h1">non-essential ship systems containing compressed air and having an assigned working pressure not exceeding 103 kPa; and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5580h0"></entry><entry colsep="0" rowsep="0" headers="t5580h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5580h1">refrigerating gas systems where the power absorbed by the gas compressor is not in excess of 10 kW, except where the gas is ammonia.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.86*" htmlwidth="11%" /><colspec colname="COLSPEC55" colwidth="7.56*" htmlwidth="7%" /><colspec colname="2" colwidth="92.50*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5581h0">Item</entry><entry namest="COLSPEC55" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5581h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5581h0">1.</entry><entry namest="COLSPEC55" nameend="2" colsep="0" rowsep="0" headers="t5581h1">For air and refrigerating gas compressors and air-driven machinery, where applicable and, in the opinion of the inspector, practicable, verification that the compressors, air-driven machinery, cooling systems, control, monitoring alarm and safety devices are in correct adjustment and operational condition.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5581h0">2.</entry><entry namest="COLSPEC55" nameend="2" colsep="0" rowsep="0" headers="t5581h1">For compressed air and refrigerating gas piping systems, where applicable and, in the opinion of the inspector, practicable,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5581h0"></entry><entry colsep="0" rowsep="0" headers="t5581h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5581h1">inspection of securing and insulating arrangements of piping systems and of locations where fluid leakage and excessive vibration may occur; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5581h0"></entry><entry colsep="0" rowsep="0" headers="t5581h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5581h1">verification that valves and fittings within the system are in correct adjustment and operational condition.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5581h0">3.</entry><entry namest="COLSPEC55" nameend="2" colsep="0" rowsep="0" headers="t5581h1">Items 1 and 2 do not apply to</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5581h0"></entry><entry colsep="0" rowsep="0" headers="t5581h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5581h1">non-essential ship systems containing compressed air and having an assigned working pressure not in excess of 103 kPa; and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5581h0"></entry><entry colsep="0" rowsep="0" headers="t5581h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5581h1">refrigerating gas systems where the power absorbed by the gas compressor is not in excess of 10 kW, except where the gas is ammonia.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic Special Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.86*" htmlwidth="11%" /><colspec colname="COLSPEC56" colwidth="7.44*" htmlwidth="7%" /><colspec colname="2" colwidth="92.62*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5582h0">Item</entry><entry namest="COLSPEC56" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5582h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5582h0">1.</entry><entry namest="COLSPEC56" nameend="2" colsep="0" rowsep="0" headers="t5582h1">For compressed air systems</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5582h0"></entry><entry colsep="0" rowsep="0" headers="t5582h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5582h1">all compressor and air driven machinery external parts and internal parts of crankcases or rotary machinery casings without further dismantling if the general condition of the machinery shows that it is suitable for further service;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5582h0"></entry><entry colsep="0" rowsep="0" headers="t5582h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5582h1">compressor machinery shut-off valves, safety devices and other components without dismantling if the general condition of the machinery shows that it is suitable for further service; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5582h0"></entry><entry colsep="0" rowsep="0" headers="t5582h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5582h1">all securing arrangements without dismantling if a general examination shows that the condition of the components is suitable for further service.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5582h0">2.</entry><entry namest="COLSPEC56" nameend="2" colsep="0" rowsep="0" headers="t5582h1">Item 1 does not apply to non-essential ship systems containing compressed air and having an assigned working pressure of not less than 103 kPa.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5582h0">3.</entry><entry namest="COLSPEC56" nameend="2" colsep="0" rowsep="0" headers="t5582h1">No periodic special inspection is required for complex mechanisms where written information is provided to the inspector from firms specializing in the reconditioning of these parts indicating that the parts are in good order and adjustment.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5583h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5583h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5583h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5583h1">At intervals not exceeding five years.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;12&quot;"><ScheduleFormHeading><Label>SCHEDULE XII</Label><TitleText>FUEL OIL SYSTEMS</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="12.47*" htmlwidth="10%" /><colspec colname="COLSPEC58" colwidth="8.86*" htmlwidth="7%" /><colspec colname="COLSPEC57" colwidth="9.23*" htmlwidth="7%" /><colspec colname="2" colwidth="93.27*" htmlwidth="75%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5584h0">Item</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5584h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">1.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Subject to items 2 and 3, fuel oil for all fixed installations shall have a flash-point of not less than 60°C (closed cup test).</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">2.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Fuel oil for fixed installations may have a flash-point of not less than 43°C (closed cup test) where</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">the ship is on geographically restricted voyages and measures are taken so that the ambient temperature of the spaces in which the fuel is stored or used does not rise to within 10°C below the flash-point of the fuel;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">the fuel oil in the storage tank is not heated to more than 38°C; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">thermostats or thermometers are fitted to the main suction lines of transfer and service pumps.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">3.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Fuel oil for emergency generator service may have a flash-point of not less than 43°C (closed cup test).</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">4.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Fixed fuel oil systems for helicopters and for non-fixed equipment shall have additional safety features taking into account the quantity of fuel carried and the hazardous properties of the fuel.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">5.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Small approved portable containers holding fuel oil with a flash-point of lower than 43°C shall</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">meet the Canadian Standards Association standard <XRefExternal reference-type="standard">Portable Containers For Gasoline and Other Petroleum Fuels</XRefExternal>, as amended from time to time; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">be stored outside machinery spaces.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">6.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">For ships operating in extremely cold conditions with exposed fuel oil piping to the emergency generator from an external deck-mounted fuel tank, means shall be taken so that the fuel oil viscosity will not adversely affect oil flow and where warming systems are used, the system shall incorporate a heat-limiting device to ensure that the oil is not heated to a temperature exceeding 20°C.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">7.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">The ventilation of spaces in which fuel oil is used shall be sufficient to prevent accumulation of oil vapour.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5584h0 t5584h1"><Emphasis style="italic">Tanks</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">8.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Fuel oil shall not be stored in the forepeak and the tanks shall, as far as practicable, form part of the ship structure.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">9.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Where fuel oil tanks, except double bottom tanks, are located adjacent to machinery spaces of category A out of necessity, they shall have a common boundary, where practicable, with the double bottom tanks, and the area of the tank boundary common with the machinery spaces of category A shall be kept to a minimum.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">10.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Where practicable, the use of non-structural fuel oil tanks shall be avoided, but where used such tanks shall</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">be fitted with a drip tray with drains that lead to a sludge tank; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">be located in spaces other than machinery spaces of category A on ships</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5584h1">certificated to carry more than 12 passengers, or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5584h1">in excess of 500 tons gross tonnage.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">11.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">No fuel oil tank shall be located where spillage or leakage from the tank creates a hazard by falling on heated surfaces.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">12.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Fuel oil tanks for cooking and cabin hot-air heating appliances shall not be installed in the same spaces as the appliances and the supply of oil to appliance burners shall be capable of being shut off from positions outside the spaces in which the appliances are fitted.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">13.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Quantities of fuel oil in tanks may be determined by</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">sounding pipes with suitable means of closure at their upper ends and terminating on the open deck if practicable; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">other safe and efficient means that on failure or over-filling of the tanks will not permit the release of fuel oil, where a supplementary means of manual sounding is provided.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">14.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Where fuel oil quantities in a tank are determined by means other than sounding pipes, the installation of the system shall be in accordance with the following requirements:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">for ships certificated to carry more than 12 passengers, the system shall not require penetration of the tank below the top; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">for ships certificated to carry 12 passengers or less, the system may include the use of oil-level gauges with flat glasses and self-closing valves between the gauges and the oil tank, but may not include the use of cylindrical gauge glasses.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">15.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Provision shall be made to prevent over-pressure in any fuel tank or system by means of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">flame-screened vent pipes terminating on the open deck if practicable; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">relief valve discharges leading back to the suction sides of pumps or to suitable tanks.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">16.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Subject to item 17, every fuel oil pipe that if damaged would allow fuel oil to escape either by gravity or siphon action from a storage, settling or daily service tank located in a space above the double bottom shall be fitted with a cock or valve on the tank that is capable of being closed from a safe location outside the space.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">17.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">In the case of deep tanks situated in any shaft or pipe tunnel or similar compact space, valves shall be fitted on the tanks and remote control may be operated by means of an additional valve outside the compact space.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">18.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Where an additional valve is fitted in the machinery space it shall be operable from outside that space.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5584h0 t5584h1"><Emphasis style="italic">Piping and Components</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">19.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">As far as practicable, all parts of a fuel oil system containing heated oil under pressure exceeding 180 kPa shall be located so that defects and leakage can be readily observed.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">20.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Machinery space fuel oil piping and components shall be adequately illuminated.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">21.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Means shall be provided to prevent oil that may escape under pressure from a component from coming into contact with heated surfaces.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">22.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Drip trays with drains leading to a sludge oil tank shall be fitted under all components where leakage may occur.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">23.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Fuel oil pipes shall be of steel or similar fire and pressure-resistant material, except that short flexible hoses may be used in accordance with Schedule IX.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">24.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Flexible hoses and end attachments shall be of fire-resistant materials of adequate strength and shall be constructed in accordance with Schedule IX.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5584h0 t5584h1"><Emphasis style="italic">Incinerators, Cooking Ranges and Cabin Hot-Air Heating Appliances</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">25.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">Printed manufacturer’s instructions for the proper installation, maintenance and operation of each fuel oil burning appliance shall be permanently mounted in a visible location adjacent to the appliance.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0">26.</entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">In addition to the instructions referred to in item 25, the following safety instructions shall be prominently posted in spaces, other than machinery spaces, where fuel oil burning appliances are located:</entry></row><row topmarginspacing="4"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" align="center" headers="t5584h1">“WARNING</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" align="center" headers="t5584h1">ENSURE THAT FRESH AIR VENTILATION SYSTEM IS IN OPERATION WHEN USING FUEL-BURNING APPLIANCE</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry namest="COLSPEC58" nameend="2" colsep="0" rowsep="0" headers="t5584h1">If leakage of fuel oil is suspected or detected the following actions should be taken immediately:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">shut off supply of fuel;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">extinguish all naked flames and sources of ignition including heaters, cookers and cigarettes; and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5584h0"></entry><entry colsep="0" rowsep="0" headers="t5584h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC57" nameend="2" colsep="0" rowsep="0" headers="t5584h1">ventilate by creating a through draught of fresh air.”</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 60)</OriginatingRef><TitleText>PLANS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC59" colwidth="7.43*" htmlwidth="7%" /><colspec colname="2" colwidth="92.62*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5585h0">Item</entry><entry namest="COLSPEC59" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5585h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5585h0">1.</entry><entry namest="COLSPEC59" nameend="2" colsep="0" rowsep="0" headers="t5585h1">General arrangement and location of permanently installed fuel oil systems including connections to boilers, engines, heat exchangers, incinerators, cooking ranges, cabin hot-air heaters, pumps, purifiers, filters, valves, pressure gauges, piping, filling stations, tanks, tank sounding devices, flame-screened venting and overflow arrangements, drip trays and sludge facilities and oil pollution prevention components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5585h0">2.</entry><entry namest="COLSPEC59" nameend="2" colsep="0" rowsep="0" headers="t5585h1">Structural details of fuel oil tanks not forming part of the hull structure and of not more than 4 500 L capacity.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5585h0">3.</entry><entry namest="COLSPEC59" nameend="2" colsep="0" rowsep="0" headers="t5585h1">Installation details indicating assigned working pressures, temperatures, flow rates and the oil flash-point (closed cup test).</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5585h0">4.</entry><entry namest="COLSPEC59" nameend="2" colsep="0" rowsep="0" headers="t5585h1">Materials, sizes, capacities, design working pressures, temperatures, testing arrangements and procedures of incinerators, pumps, purifiers, filters, valves, tank sounding and venting devices, piping and other components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5585h0">5.</entry><entry namest="COLSPEC59" nameend="2" colsep="0" rowsep="0" headers="t5585h1">Details of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5585h0"></entry><entry colsep="0" rowsep="0" headers="t5585h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5585h1">pipe connections to flanges or other joining arrangements;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5585h0"></entry><entry colsep="0" rowsep="0" headers="t5585h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5585h1">securing arrangements for pumps, non-structural tanks, appliances, piping, flexible hose installations and other components;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5585h0"></entry><entry colsep="0" rowsep="0" headers="t5585h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5585h1">piping insulation and hazard protection particularly against heated oil;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5585h0"></entry><entry colsep="0" rowsep="0" headers="t5585h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5585h1">cross connection with other systems; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5585h0"></entry><entry colsep="0" rowsep="0" headers="t5585h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5585h1">remote control of valves in systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5585h0">6.</entry><entry namest="COLSPEC59" nameend="2" colsep="0" rowsep="0" headers="t5585h1">Information set out in items 3 to 5 need not be submitted for ships not in excess of 18 m in length.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5585h0">7.</entry><entry namest="COLSPEC59" nameend="2" colsep="0" rowsep="0" headers="t5585h1">Information for valves and similar minor components referred to in item 4 is not required to be submitted where a manufacturer or an approved classification society certifies that the types of valves or similar minor components have been designed and constructed in accordance with rules or codes.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5585h0">8.</entry><entry namest="COLSPEC59" nameend="2" colsep="0" rowsep="0" headers="t5585h1">Information for pumps or purifiers referred to in item 4 is not required to be submitted where an approved classification society certifies that the pumps or purifiers have been designed and constructed in accordance with rules or codes except that the driving motor or engine of pumps shall meet the requirements of Part II of the applicable schedule of Schedules I to XV.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5586h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5586h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5586h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5586h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Installation Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.67*" htmlwidth="11%" /><colspec colname="2" colwidth="89.33*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5587h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5587h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5587h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5587h1">Identification from component inspection certificates, before installation is commenced, of pumps, appliances, piping, tank sounding and venting devices, flexible hoses, materials, including weld metal, oil pollution prevention equipment and other components to be used.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5587h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5587h1">Verification that welding was carried out by welders certified by a Provincial Government of Canada, or another authority having similar standards where the welding was carried out outside Canada, for the class of work to be done.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5587h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5587h1">Inspection of welds.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5587h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5587h1">Witnessing of hydrostatic pressure tests in accordance with rules or codes and verification of system flushing.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5587h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5587h1">Inspection of securing arrangements of pumps, heat exchangers and appliances, connection of piping to associated systems and verification of correct adjustment and operational condition of safety, control and monitoring devices.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5587h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5587h1">Witnessing of operational tests of the system in accordance with rules or codes.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC60" colwidth="7.43*" htmlwidth="7%" /><colspec colname="2" colwidth="92.61*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5588h0">Item</entry><entry namest="COLSPEC60" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5588h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5588h0">1.</entry><entry namest="COLSPEC60" nameend="2" colsep="0" rowsep="0" headers="t5588h1">Where applicable and, in the opinion of the inspector, practicable,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5588h0"></entry><entry colsep="0" rowsep="0" headers="t5588h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5588h1">inspection of securing arrangements and of locations where fluid leakage or excessive vibration may occur, particularly from any heated oil piping and flexible hoses;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5588h0"></entry><entry colsep="0" rowsep="0" headers="t5588h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5588h1">verification that pumps, heat exchangers, appliances, control, monitoring and alarm systems, tank sounding and venting devices and all oil pollution control devices are in correct adjustment and operational condition;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5588h0"></entry><entry colsep="0" rowsep="0" headers="t5588h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5588h1">verification that documentation is held aboard the ship indicating the closed cup test flash point of the ship’s fuel oil; and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5588h0"></entry><entry colsep="0" rowsep="0" headers="t5588h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5588h1">verification that a 0.25 L minimum sample of the fuel oil that is carried and used on board the ship is held aboard ships of 500 tons gross tonnage and over until the fuel oil is completely used.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic Special Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5589h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5589h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5589h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5589h1">External and internal parts of pumps and driving components including valves, bearings, control and safety devices, except gear or rotary pumps where dismantling is not required if a general examination shows that the condition of components is suitable for further service.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5589h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5589h1">Systems shut-off valves, safety devices and other components without dismantling if a general examination shows that the condition of the components is suitable for further service.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5589h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5589h1">Securing arrangements of components without dismantling if a general examination shows that the condition of the securing arrangements is suitable for further service.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5589h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5589h1">No special periodic inspection is required for complex mechanisms where written information is provided to the inspector from firms specializing in the reconditioning of these parts that the parts are in good order and adjustment.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5590h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5590h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5590h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5590h1">At intervals not exceeding five years.</entry></row></tbody></tgroup></table></TableGroup><HistoricalNote><ul><li>SOR/95-372, s. 7(F).</li></ul></HistoricalNote></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;13&quot;"><ScheduleFormHeading><Label>SCHEDULE XIII</Label><TitleText>LIQUEFIED PETROLEUM GAS FUEL SYSTEMS</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Application</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC61" colwidth="7.55*" htmlwidth="7%" /><colspec colname="2" colwidth="92.49*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5591h0">Item</entry><entry namest="COLSPEC61" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5591h1">Description of Appliances</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5591h0">1.</entry><entry namest="COLSPEC61" nameend="2" colsep="0" rowsep="0" headers="t5591h1">This Schedule applies to the following galley and cabin-heating appliances aboard non-passenger ships:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5591h0"></entry><entry colsep="0" rowsep="0" headers="t5591h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5591h1">domestic gas fuel burning ranges;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5591h0"></entry><entry colsep="0" rowsep="0" headers="t5591h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5591h1">domestic gas fuel refrigerators;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5591h0"></entry><entry colsep="0" rowsep="0" headers="t5591h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5591h1">gas fuel space-heaters; and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5591h0"></entry><entry colsep="0" rowsep="0" headers="t5591h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5591h1">gas fuel water-heaters.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Specifications</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="12.87*" htmlwidth="10%" /><colspec colname="COLSPEC63" colwidth="8.60*" htmlwidth="7%" /><colspec colname="COLSPEC62" colwidth="8.42*" htmlwidth="7%" /><colspec colname="2" colwidth="93.94*" htmlwidth="76%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5592h0">Item</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5592h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">1.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Gas fuel shall have a distinctive odour to indicate the presence of gas down to a concentration of 20 per cent of the lower explosive limit of the gas in the air.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">2.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">No liquefied petroleum gas fuel system of a type other than the vapour withdrawal type shall be installed or used in a ship.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">3.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Gas fuel cylinders and regulating and safety devices shall be securely fastened and so located that escaping vapour cannot reach bilges, machinery spaces, accommodation or other enclosed spaces.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">4.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Location of gas fuel cylinders, regulation arrangements and relief valve outlets shall be located only on open decks, on cabin tops, outside cockpits or inside housings that are gas-tight to the hull interior.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">5.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Appliances shall be installed in accordance with the manufacturer’s instructions and shall be securely fastened.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">6.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Appliances shall be connected in a manner that prevents undue strain on the piping.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">7.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Only liquefied petroleum gas fuel cylinders that meet the requirements of the Transport of Dangerous Goods Directorate of the Department of Transport or the Interstate Commerce Commission of the United States shall be used.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">8.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Liquefied petroleum gas fuel system components and piping shall have a design working pressure of not less than 1 725 kPa.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5592h0 t5592h1"><Emphasis style="italic">Piping Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">9.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Gas fuel piping shall</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">be adequately flexible and protected from damage;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">have a minimum of piping in enclosed spaces;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">be exposed to sight as far as practicable;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">be supported by hangers that will not cause damage or corrosion and that are spaced at intervals not exceeding 120 times the outside diameter of the pipe; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">have non-abrasive covering for protection where they pass through decks or bulkheads.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">10.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Gas fuel piping shall not be used as part of any electrical circuit or grounding system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">11.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Gas fuel piping shall not be used as support or restraint for any item or fitting that is not part of the gas system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">12.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Any valves, regulators or other fittings exceeding 0.5 kg mass per 6 mm of pipe outside diameter shall have their mass supported by means other than the gas piping.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">13.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Gas fuel piping shall be of a sufficient diameter to provide a sufficient supply of gas fuel to meet demand pressures at the point of use and the pressure drop between the regulator and the appliance shall not exceed 10 per cent.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">14.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">High-pressure liquefied petroleum gas fuel piping between the gas storage cylinders and the regulators shall have a minimum wall thickness of 1.24 mm and the low-pressure gas fuel piping between the regulators and the gas-burning appliances shall have a minimum wall thickness of 0.81 mm.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">15.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Liquefied petroleum gas fuel piping shall</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">be of seamless steel or copper;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">have welded, brazed, threaded or flared connections;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">where brazed connections are used, have brazing metal with a melting point in excess of 540°C; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">where carbon steel is used, be painted on its exterior surfaces to prevent corrosion.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">16.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Short reinforced flexible hoses and couplings used to connect the gas fuel piping system to a cylinder or gimballed appliance shall be of a type referred to in item 24.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">17.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Short reinforced flexible hoses shall be of the minimum practicable length but not longer than 1 m and shall not extend from one cabin to another or pass through any bulkheads, partitions, deck heads or decks.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5592h0 t5592h1"><Emphasis style="italic">Gas Storage Cylinders</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">18.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">No gas fuel storage cylinder that permits gas in liquid form to enter any other part of the gas system shall be used.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">19.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Each liquefied petroleum gas fuel storage cylinder shall have a manually operated screw-down shut-off valve mounted directly on the cylinder outlet.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">20.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">The manually operated screw-down shut-off valve shall be fitted with a spring-loaded safety device and with a fusible plug designed to yield when the cylinder has been emptied of liquefied petroleum gas by the relief valve under exposure to excessive heat.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">21.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">The shut-off valve, the spring-loaded safety device and the fusible plug referred to in item 20 shall each have direct communication with the vapour space of a gas fuel storage cylinder.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">22.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">A multiple-cylinder gas fuel system shall be fitted with a manually operated two-way positive shut-off manifold valve so arranged that the replacement of empty cylinders may be made without shutting down the flow of gas in the gas fuel system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">23.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">No electrical connections shall be made within a gas fuel storage cylinder enclosure.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5592h0 t5592h1"><Emphasis style="italic">Gas Fuel Components and Appliances</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">24.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Except for the gas fuel storage cylinders, only gas fuel components and appliances that meet the requirements of the Canadian Gas Association, the Compressed Gas Association, the Underwriters’ Laboratories of Canada or the Underwriters’ Laboratories Incorporated shall be used.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">25.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">All valves and regulators embodied in the gas fuel system for the purpose of pressure relief, regulation or control of gas pressure and flow rates shall be securely mounted in a position readily accessible for operation, inspection, maintenance and testing, and shall be protected against physical damage.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">26.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">The gas fuel system shall be fitted with a regulating device adjusted to release gas to the consuming appliance at a pressure not in excess of 4.5 kPa.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">27.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">The low-pressure side of all regulators in the gas fuel system shall be protected against excessive pressure by means of a suitable relief valve that is fitted to the regulator and set to discharge at a pressure of not less than twice, and not more than three times, the delivery pressure.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">28.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">All regulators in the gas fuel system shall be fitted with a pressure gauge located on the high-pressure side of the regulator.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">29.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">A master packless shut-off valve controlling all burners simultaneously shall be installed on the console of each gas-burning appliance.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">30.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">All appliances incorporating pilot-lights or other continuous-burning flame devices shall incorporate a flame failure device arranged to shut off the main and pilot gas in the event of flame failure.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">31.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Installation clearances between appliances and adjacent combustible material shall not be less than the clearances specified in the manufacturer’s instructions.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">32.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">The piping and components in the gas fuel system shall be located so that gas leakage tests may be carried out at prescribed intervals as follows:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">note the pressure on the gauge when the appliance burner valves are shut and the packless shut-off valve and one cylinder valve are open;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">note if the pressure on the gauge remains constant for at least 10 minutes when the cylinder valve is closed;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">if the pressure on the gauge drops before the expiration of 10 minutes, locate the leakage by applying liquid detergent or soap water solution to all connections of the gas fuel system but do not use flame to test for leaks; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">repeat subitems (<Emphasis style="italic">a</Emphasis>), (<Emphasis style="italic">b</Emphasis>) and (<Emphasis style="italic">c</Emphasis>) for each cylinder in a multi-cylinder gas fuel system.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5592h0 t5592h1"><Emphasis style="italic">Systems Installation for Ships Exceeding 24 m in Length</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">33.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Gas fuel storage cylinders and pressure-regulating and relief arrangements shall be</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">installed in a sturdily constructed metal enclosure with ventilation openings at both the top and the bottom of the enclosure;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">protected from damage, direct rays of the sun and heat; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">located on or above the weather deck level and outside the superstructure, with access only from the open deck.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">34.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Spare and empty gas fuel cylinders shall have valve outlets that are capped and may be stored within the metal enclosure or may be secured on the open deck in a location that is protected from damage, direct rays of the sun and heat by a suitable cover, and the enclosure or cover shall be ventilated to prevent the accumulation of gas.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">35.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">The metal enclosure shall be designed to be closed at all times except when access is required to change cylinders in the gas system or to maintain equipment, and only the following items shall be stored in the enclosure:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">liquefied petroleum gas fuel storage cylinders and permanently secured system components; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">secured valve-protecting caps for cylinders that are in use.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">36.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Gas fuel storage cylinder pressure-relief valves shall be vented away from the cylinders and, as far as practicable, upwards to prevent impingement of escaping gas onto the cylinders.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">37.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Gas fuel safety device vent outlets shall end at least 1.5 m from enclosed space openings and ventilation intakes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">38.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Compartments containing liquefied petroleum gas-burning appliances that are located above the weather deck shall be ventilated by</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">at least two natural air ventilator ducts each of which is at least 75 mm in diameter, one leading to and the other leading from the open deck and the extraction duct shall extend from within 15 cm of the deck of the compartment and the inlet duct shall extend to within 15 cm of the deckhead of the compartment; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">mechanical ventilation arranged in a manner similar to that described in subitem (<Emphasis style="italic">a</Emphasis>) except that the duct size shall be determined on the basis of at least 10 air changes per hour within the compartment and the fan and its motor, if not spark-proof, shall not be located in the compartment or the extraction duct.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">39.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Compartments that contain liquefied petroleum gas-burning appliances or in which gas may accumulate and that are located entirely below the weather deck shall be ventilated by mechanical ventilation of the positive extraction type with a spark-proof fan and motor having sufficient capacity to effect at least 10 air changes per hour through ventilators leading to and from the open deck and the extraction duct of the ventilator shall extend from the deck level and the inlet duct of the ventilator shall extend to the deckhead of the compartment.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5592h0 t5592h1"><Emphasis style="italic">Systems Installation for Ships not Exceeding 24 m in Length</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">40.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Gas fuel storage cylinders and pressure-regulating and relief arrangements shall be</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">protected from damage, direct rays of the sun and heat; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">located on or above the weather deck level, outside the superstructure, with access only from the open deck.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">41.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Gas fuel storage cylinder pressure-relief valves shall be vented away from the cylinders, and, as far as practicable, upwards to prevent impingement of escaping gas onto the cylinders.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">42.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Gas fuel safety device vent outlets from safety devices shall end as far as practicable from enclosed space openings and ventilation intakes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">43.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Spare and empty gas fuel cylinders shall have valve outlets that are capped, secured on the open deck and protected from damage, direct rays of the sun and heat.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">44.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Compartments that contain gas-burning appliances or in which gas may accumulate shall be efficiently ventilated so that inside air is exhausted through a vent opening located at the lowest part of the compartments.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5592h0 t5592h1"><Emphasis style="italic">Safety Notices for All Ships</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">45.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Printed manufacturer’s instructions for the proper installation, maintenance and operation of each gas-burning appliance shall be permanently mounted in a readily visible location adjacent to the appliance.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">46.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">The gas fuel cylinder storage location shall prominently display the following warning and operating instructions:</entry></row><row topmarginspacing="6"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" align="center" headers="t5592h1">“WARNING</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" align="center" headers="t5592h1">LIQUEFIED PETROLEUM GAS FUEL</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" align="center" headers="t5592h1">NO OPEN FLAME</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" align="center" headers="t5592h1">NO SMOKING</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" align="center" headers="t5592h1">BEFORE TURNING ON GAS FUEL READ OPERATING INSTRUCTIONS BELOW</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" align="center" headers="t5592h1">KEEP CYLINDER VALVES CLOSED WHEN CYLINDER EMPTY OR SHIP IS UNATTENDED</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" align="center" headers="t5592h1">BE SURE ALL APPLIANCE VALVES ARE CLOSED BEFORE OPENING THE CYLINDER VALVES</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" align="center" headers="t5592h1">CLOSE APPLIANCE VALVES WHEN APPLIANCE IS NOT IN USE</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" align="center" headers="t5592h1">TEST SYSTEM FOR LEAKAGE AT LEAST TWICE A MONTH</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" align="center" headers="t5592h1">CONSUMER OPERATING INSTRUCTIONS</entry></row><row topmarginspacing="4"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">1.</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Read and observe the appliance manufacturer’s instructions.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">2.</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Never use a gas fuel appliance without ventilation.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">3.</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">Do not use the cooking appliance for space-heating.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">4.</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">To remove an empty cylinder:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">close cylinder valve and burn out the gas fuel in the line by lighting all appliance burners;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">when the gas stops burning, close the appliance valves; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">disconnect the empty cylinder, leaving the cylinder valve closed.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">5.</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">To install a full cylinder:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">check that all appliance valves are in the closed position;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">secure the cylinder to mounting and the outlet of the cylinder valve to the gas fuel system;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">open the cylinder valve and test cylinder and regulator connections for leaks with a soap and water solution or another leak detection device, but never use a naked flame for testing; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">one at a time, open the appliance valves and light the burners and allow for a sufficient length of time to ensure that there is no air in the lines to interrupt gas fuel flow.”</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0">47.</entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" headers="t5592h1">The following warning and safety instructions shall be prominently posted in spaces where gas fuel appliances are located:</entry></row><row topmarginspacing="6"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" align="center" headers="t5592h1">“WARNING</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry namest="COLSPEC63" nameend="2" colsep="0" rowsep="0" align="center" headers="t5592h1">ENSURE THAT FRESH AIR VENTILATION SYSTEM IS IN OPERATION WHEN USING FUEL-BURNING APPLIANCE</entry></row><row topmarginspacing="4"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">1.</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">If leakage of gas fuel is suspected or detected, the following actions should be taken immediately:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">shut off the supply of gas by closing the main cylinder valve or valves;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">extinguish all naked flames and other sources of ignition, including heaters, cookers, pilot lights and cigarettes;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">do not operate electric switches or cause electric sparks;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">advise the Master or engineer;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">ventilate by creating a through draught to disperse the gas as liquefied petroleum gas is heavier than air and will tend to settle;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">f</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">if possible evacuate the area because a leak with no fire may form an explosive mixture; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1"></entry><entry colsep="0" rowsep="0" headers="t5592h1">(<Emphasis style="italic">g</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5592h1">remove all cylinders from the vessel if leakage cannot be stopped.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5592h0"></entry><entry colsep="0" rowsep="0" headers="t5592h1">2.</entry><entry namest="COLSPEC62" nameend="2" colsep="0" rowsep="0" headers="t5592h1">If any soot accumulates on pans or parts of the appliance or any unusual odours occur, the appliance should not be used until it is repaired as the appliance may be producing a deadly gas.”</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC64" colwidth="7.43*" htmlwidth="7%" /><colspec colname="2" colwidth="92.62*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5593h0">Item</entry><entry namest="COLSPEC64" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5593h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5593h0">1.</entry><entry namest="COLSPEC64" nameend="2" colsep="0" rowsep="0" headers="t5593h1">General arrangement and location of the complete system including gas fuel cylinders, components, piping, appliances, venting and safety arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5593h0">2.</entry><entry namest="COLSPEC64" nameend="2" colsep="0" rowsep="0" headers="t5593h1">Installation details stating assigned working pressures, materials and sizes of cylinders, components, piping and appliances.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5593h0">3.</entry><entry namest="COLSPEC64" nameend="2" colsep="0" rowsep="0" headers="t5593h1">Details of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5593h0"></entry><entry colsep="0" rowsep="0" headers="t5593h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5593h1">cylinder, component, piping and appliance connections;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5593h0"></entry><entry colsep="0" rowsep="0" headers="t5593h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5593h1">securing arrangements for cylinders, components, pipes and appliances; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5593h0"></entry><entry colsep="0" rowsep="0" headers="t5593h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5593h1">hazard protection for cylinders, components, pipes and appliances.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5593h0">4.</entry><entry namest="COLSPEC64" nameend="2" colsep="0" rowsep="0" headers="t5593h1">Data indicating the authority referred to in items 7 and 24 of Division II of Part I for cylinders, components and appliances.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5593h0">5.</entry><entry namest="COLSPEC64" nameend="2" colsep="0" rowsep="0" headers="t5593h1">Information set out in items 1 to 4 is not required to be submitted for ships not exceeding 24 m in length.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5594h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5594h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5594h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5594h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Installation Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC65" colwidth="7.55*" htmlwidth="7%" /><colspec colname="2" colwidth="92.50*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5595h0">Item</entry><entry namest="COLSPEC65" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5595h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5595h0">1.</entry><entry namest="COLSPEC65" nameend="2" colsep="0" rowsep="0" headers="t5595h1">Identification from component inspection certificates, before installation is commenced, of gas fuel storage cylinders, components, piping, flexible hoses, appliances and vent fans.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5595h0">2.</entry><entry namest="COLSPEC65" nameend="2" colsep="0" rowsep="0" headers="t5595h1">Inspection of securing arrangements, protective housings, component and piping connections, venting arrangements, all safety devices and arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5595h0">3.</entry><entry namest="COLSPEC65" nameend="2" colsep="0" rowsep="0" headers="t5595h1">Witnessing of gas fuel pressure and leakage tests as follows:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5595h0"></entry><entry colsep="0" rowsep="0" headers="t5595h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5595h1">note the pressure on the gauge when the appliance burner valves are shut and the packless shut-off valve and one cylinder valve are open;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5595h0"></entry><entry colsep="0" rowsep="0" headers="t5595h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5595h1">note if the pressure on the gauge remains constant for at least 10 minutes when the cylinder valve is closed;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5595h0"></entry><entry colsep="0" rowsep="0" headers="t5595h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5595h1">if the pressure on the gauge drops before the expiration of 10 minutes, locate the leakage by applying liquid detergent or soap water solution to all connections of the gas system but do not use flame to test for leaks; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5595h0"></entry><entry colsep="0" rowsep="0" headers="t5595h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5595h1">repeat subitems (<Emphasis style="italic">a</Emphasis>), (<Emphasis style="italic">b</Emphasis>) and (<Emphasis style="italic">c</Emphasis>) for each cylinder in a multi-cylinder gas fuel system.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5595h0">4.</entry><entry namest="COLSPEC65" nameend="2" colsep="0" rowsep="0" headers="t5595h1">Witnessing of operational tests of the system and verification that safety and operating instructions are posted in accordance with items 44 and 45 of Division II of Part I.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.34*" htmlwidth="10%" /><colspec colname="2" colwidth="89.66*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5596h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5596h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5596h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5596h1">Inspection of securing arrangements and for evidence of gas fuel leakage.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5596h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5596h1">Verification that all components and venting systems are in correct adjustment and operational condition.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5596h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5596h1">Verification that safety and operating instructions are correctly posted.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic Special Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC66" colwidth="7.43*" htmlwidth="7%" /><colspec colname="2" colwidth="92.62*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5597h0">Item</entry><entry namest="COLSPEC66" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5597h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5597h0">1.</entry><entry namest="COLSPEC66" nameend="2" colsep="0" rowsep="0" headers="t5597h1">Entire gas fuel systems</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5597h0"></entry><entry colsep="0" rowsep="0" headers="t5597h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5597h1">for evidence of deterioration or leakage without dismantling if a general examination shows that the condition of the liquefied petroleum gas fuel systems is suitable for further service; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5597h0"></entry><entry colsep="0" rowsep="0" headers="t5597h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5597h1">by witnessing of a gas leakage test in accordance with item 3 of Division II of Part III.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5597h0">2.</entry><entry namest="COLSPEC66" nameend="2" colsep="0" rowsep="0" headers="t5597h1">Securing arrangements of gas fuel systems without dismantling if a general examination shows that the condition of components is suitable for further service.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5597h0">3.</entry><entry namest="COLSPEC66" nameend="2" colsep="0" rowsep="0" headers="t5597h1">Gas cylinders to verify that they have been tested in accordance with the requirements of the Transport of Dangerous Goods Directorate of the Department of Transport.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5597h0">4.</entry><entry namest="COLSPEC66" nameend="2" colsep="0" rowsep="0" headers="t5597h1">A gas fuel storage cylinder shall be rejected for further service regardless of the date of its previous test if it</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5597h0"></entry><entry colsep="0" rowsep="0" headers="t5597h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5597h1">leaks;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5597h0"></entry><entry colsep="0" rowsep="0" headers="t5597h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5597h1">is weakened appreciably by corrosion, denting or bulging or shows other evidence of rough usage;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5597h0"></entry><entry colsep="0" rowsep="0" headers="t5597h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5597h1">has lost five per cent of its tare weight; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5597h0"></entry><entry colsep="0" rowsep="0" headers="t5597h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5597h1">has been in a fire.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5597h0">5.</entry><entry namest="COLSPEC66" nameend="2" colsep="0" rowsep="0" headers="t5597h1">Fans and ducting of venting systems to verify that they are suitable for the required use.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5598h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5598h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5598h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5598h1">At intervals not exceeding five years.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;14&quot;"><ScheduleFormHeading><Label>SCHEDULE XIV</Label><TitleText>LUBRICATING OIL AND HYDRAULIC POWER OIL SYSTEMS</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC67" colwidth="7.31*" htmlwidth="7%" /><colspec colname="2" colwidth="92.74*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5599h0">Item</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5599h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">1.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">Where the ship is to operate in low ambient temperatures, measures shall be taken to maintain essential deck machinery lubricating oil and hydraulic power oil at a viscosity suitable for reliable operation of the machinery.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5599h0 t5599h1"><Emphasis style="italic">Tanks</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">2.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">No lubricating oil or hydraulic power oil tank shall be located where spillage or leakage from the tanks creates a hazard by falling on heated surfaces.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">3.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">No lubricating oil or hydraulic power oil shall be carried in the fore-peak.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">4.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">Means shall be provided to prevent over-pressure in</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0"></entry><entry colsep="0" rowsep="0" headers="t5599h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5599h1">any lubricating oil or hydraulic power oil tank by way of flame screened vent pipes terminating in a safe location; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0"></entry><entry colsep="0" rowsep="0" headers="t5599h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5599h1">any lubricating oil or hydraulic power oil system by relief valve discharges leading back to suction sides of pumps or to suitable tanks.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">5.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">Quantities of lubricating oil or hydraulic power oil in tanks may be determined by</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0"></entry><entry colsep="0" rowsep="0" headers="t5599h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5599h1">sounding pipes with suitable means of closure at their upper ends that terminate in a safe location;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0"></entry><entry colsep="0" rowsep="0" headers="t5599h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5599h1">heat resistant gauge glasses protected from mechanical damage and fitted with self-closing valves at the lower end and at the top of the glasses if the valves are connected to the tank below the maximum liquid level; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0"></entry><entry colsep="0" rowsep="0" headers="t5599h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5599h1">other safe and efficient means where a supplementary means of manual sounding is fitted.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">6.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">Subject to item 7, for ships certificated to carry more than 12 passengers and other ships in excess of 500 tons gross tonnage, every pressurized lubricating oil system pipe which when damaged allows oil to escape from a storage or service tank situated above the double bottom, shall be fitted with a cock or valve on the tank capable of being closed from a safe position outside the space.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">7.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">In the case of tanks situated in any shaft or pipe tunnel or similar compact space, cocks or valves shall be fitted on the tanks and remote control may be operated by means of an additional valve outside the compact space.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">8.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">Where the additional valve is fitted in the machinery space it shall be operable from outside this space.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5599h0 t5599h1"><Emphasis style="italic">Piping and Components</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">9.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">As far as practicable, all parts of a lubricating oil or hydraulic power oil system containing heated oil under pressure exceeding 180 kPa shall be located so that defects and leakage can readily be observed.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">10.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">Machinery space lubricating oil and hydraulic power oil piping and components shall be adequately illuminated.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">11.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">Means shall be taken to prevent oil that may escape under pressure from any component from coming into contact with heated surfaces.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">12.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">Drip trays with drains leading to a sludge oil tank shall be fitted under all components where leakage may occur.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">13.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">Lubricating oil and hydraulic power oil pipes shall be of steel or similar fire and pressure resistant material, except that flexible hoses are permissible in accordance with Schedule IX.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5599h0">14.</entry><entry namest="COLSPEC67" nameend="2" colsep="0" rowsep="0" headers="t5599h1">Sight flow glasses in piping systems shall be of fire resistant types.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="12.87*" htmlwidth="10%" /><colspec colname="COLSPEC69" colwidth="8.46*" htmlwidth="7%" /><colspec colname="COLSPEC68" colwidth="8.96*" htmlwidth="7%" /><colspec colname="2" colwidth="93.52*" htmlwidth="76%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5600h0">Item</entry><entry namest="COLSPEC69" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5600h1">Required Information</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0">1.</entry><entry namest="COLSPEC69" nameend="2" colsep="0" rowsep="0" headers="t5600h1">General arrangement and location of permanently installed oil systems, including connections to all applicable machinery, heat exchangers, pumps, purifiers, filters, valves, piping, filling stations, tanks, tank sounding devices, flame screened venting and overflow arrangements, drip-trays and sludge facilities and oil pollution prevention components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0">2.</entry><entry namest="COLSPEC69" nameend="2" colsep="0" rowsep="0" headers="t5600h1">Structural details of tanks not forming part of the hull structure.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0">3.</entry><entry namest="COLSPEC69" nameend="2" colsep="0" rowsep="0" headers="t5600h1">Installation details indicating assigned working pressures, temperatures, flow rates, oil flash-point (closed cup test) and oil viscosity at highest and lowest operating temperatures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0">4.</entry><entry namest="COLSPEC69" nameend="2" colsep="0" rowsep="0" headers="t5600h1">Materials, sizes, capacities, design working pressures, temperatures, testing arrangements and procedures of pumps, purifiers, piping, valves and other components.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0">5.</entry><entry namest="COLSPEC69" nameend="2" colsep="0" rowsep="0" headers="t5600h1">Details of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0"></entry><entry colsep="0" rowsep="0" headers="t5600h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC68" nameend="2" colsep="0" rowsep="0" headers="t5600h1">pipe connections to flanges or other joining arrangements;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0"></entry><entry colsep="0" rowsep="0" headers="t5600h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC68" nameend="2" colsep="0" rowsep="0" headers="t5600h1">securing arrangements for pumps, non-structural tanks, piping, flexible hose installations and other components;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0"></entry><entry colsep="0" rowsep="0" headers="t5600h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC68" nameend="2" colsep="0" rowsep="0" headers="t5600h1">piping hazard protection, particularly against heated oil; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0"></entry><entry colsep="0" rowsep="0" headers="t5600h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry namest="COLSPEC68" nameend="2" colsep="0" rowsep="0" headers="t5600h1">remote control of valves in systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0">6.</entry><entry namest="COLSPEC69" nameend="2" colsep="0" rowsep="0" headers="t5600h1">Information set out in items 1 and 3 to 5 is not required to be submitted for</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0"></entry><entry colsep="0" rowsep="0" headers="t5600h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC68" nameend="2" colsep="0" rowsep="0" headers="t5600h1">ships not in excess of 18 m in length and certificated to carry not more than 12 passengers;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0"></entry><entry colsep="0" rowsep="0" headers="t5600h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC68" nameend="2" colsep="0" rowsep="0" headers="t5600h1">a lubricating oil system in which the oil storage tank capacity is not in excess of 250 L; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0"></entry><entry colsep="0" rowsep="0" headers="t5600h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC68" nameend="2" colsep="0" rowsep="0" headers="t5600h1">a hydraulic power oil system for</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0"></entry><entry colsep="0" rowsep="0" headers="t5600h1"></entry><entry colsep="0" rowsep="0" headers="t5600h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5600h1">non-essential services, or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0"></entry><entry colsep="0" rowsep="0" headers="t5600h1"></entry><entry colsep="0" rowsep="0" headers="t5600h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5600h1">units where the total output power is not in excess of 2 kW.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0">7.</entry><entry namest="COLSPEC69" nameend="2" colsep="0" rowsep="0" headers="t5600h1">Information for valves and similar minor fittings referred to in item 4 is not required to be submitted where a manufacturer or an approved classification society certifies that the types of valves or similar minor components have been designed and constructed in accordance with rules or codes.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5600h0">8.</entry><entry namest="COLSPEC69" nameend="2" colsep="0" rowsep="0" headers="t5600h1">Information for pumps and purifiers referred to in item 4 is not required to be submitted where an approved classification society certifies that the pumps or purifiers have been designed and constructed in accordance with rules or codes except that the driving motor or engine of pumps shall meet the requirements of Part II of the applicable schedule of Schedules I to XV.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5601h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5601h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5601h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5601h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Installation Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.34*" htmlwidth="10%" /><colspec colname="2" colwidth="89.66*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5602h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5602h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5602h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5602h1">Identification from component inspection certificates, before installation is commenced, of pumps, applicable essential machinery, piping, flexible hoses, materials, including welding metal, and other components to be used.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5602h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5602h1">Verification that welding was carried out by welders certified by a Provincial Government of Canada, or another authority having similar standards where the welding was carried out outside Canada, for the class of work to be done.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5602h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5602h1">Inspection of welds.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5602h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5602h1">Witnessing of hydrostatic pressure tests in accordance with rules or codes and verification of system flushing.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5602h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5602h1">Inspection of securing arrangements of the lubricating oil and hydraulic power oil system and verification of correct adjustment and operational condition of safety, control and monitoring devices.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5602h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5602h1">Witnessing of operational tests of the system in accordance with rules or codes.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC70" colwidth="7.55*" htmlwidth="7%" /><colspec colname="2" colwidth="92.50*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5603h0">Item</entry><entry namest="COLSPEC70" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5603h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5603h0">1.</entry><entry namest="COLSPEC70" nameend="2" colsep="0" rowsep="0" headers="t5603h1">For essential lubricating oil and hydraulic power oil systems and, in locations where oil leakage is hazardous, non-essential systems,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5603h0"></entry><entry colsep="0" rowsep="0" headers="t5603h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5603h1">inspection of securing arrangements and of locations where fluid leakage or excessive vibration may occur, particularly any heated piping or flexible hoses;</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5603h0"></entry><entry colsep="0" rowsep="0" headers="t5603h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5603h1">verification that the lubricating oil and hydraulic power oil system, control, monitoring and alarm systems are in correct adjustment and operational condition.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic Special Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC71" colwidth="7.43*" htmlwidth="7%" /><colspec colname="2" colwidth="92.62*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5604h0">Item</entry><entry namest="COLSPEC71" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5604h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5604h0">1.</entry><entry namest="COLSPEC71" nameend="2" colsep="0" rowsep="0" headers="t5604h1">For essential lubricating oil and hydraulic power oil systems,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5604h0"></entry><entry colsep="0" rowsep="0" headers="t5604h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5604h1">external and internal parts of pumps and driving components including valves, bearings, controls, and safety devices, except gear or rotary pumps where dismantling is not required if a general examination shows that the condition of the components is suitable for further service;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5604h0"></entry><entry colsep="0" rowsep="0" headers="t5604h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5604h1">systems shut-off valves, safety devices and other components without dismantling if a general examination shows that the condition of the components is suitable for further service; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5604h0"></entry><entry colsep="0" rowsep="0" headers="t5604h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5604h1">securing arrangements without dismantling if a general examination shows that the condition of the components is suitable for further service.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5604h0">2.</entry><entry namest="COLSPEC71" nameend="2" colsep="0" rowsep="0" headers="t5604h1">No periodic special inspection is required for complex mechanisms where written information is provided to the inspector from firms specializing in the reconditioning of these parts that the parts are in good order and adjustment.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5605h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5605h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5605h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5605h1">At intervals not exceeding five years.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;15&quot;"><ScheduleFormHeading><Label>SCHEDULE XV</Label><TitleText>BILGE AND BALLAST PUMPING SYSTEMS, HEELING, TRIMMING AND PASSIVE ROLL STABILIZING TANK FILLING AND EMPTYING SYSTEMS</TitleText></ScheduleFormHeading><Heading level="1"><Label>PART I</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>DESIGN SPECIFICATIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Application</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="5"><colspec colname="1" colwidth="13.51*" htmlwidth="10%" /><colspec colname="COLSPEC74" colwidth="8.24*" htmlwidth="6%" /><colspec colname="COLSPEC73" colwidth="10.08*" htmlwidth="8%" /><colspec colname="COLSPEC72" colwidth="10.27*" htmlwidth="8%" /><colspec colname="2" colwidth="88.13*" htmlwidth="68%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5606h0">Item</entry><entry namest="COLSPEC74" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5606h1">Description of Ships</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5606h0">1.</entry><entry namest="COLSPEC74" nameend="2" colsep="0" rowsep="0" headers="t5606h1">In this Schedule,</entry></row><row topmarginspacing="4"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5606h0"></entry><entry namest="COLSPEC74" nameend="2" colsep="0" rowsep="0" headers="t5606h1">“Group 1 ship” means a ship certificated to carry more than 12 passengers that is on a voyage as follows:</entry></row><row topmarginspacing="4"><entry colsep="0" rowsep="0" headers="t5606h0"></entry><entry colsep="0" rowsep="0" headers="t5606h1"></entry><entry colsep="0" rowsep="0" headers="t5606h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC72" nameend="2" colsep="0" rowsep="0" headers="t5606h1">Foreign Going, or</entry></row><row topmarginspacing="4"><entry colsep="0" rowsep="0" headers="t5606h0"></entry><entry colsep="0" rowsep="0" headers="t5606h1"></entry><entry colsep="0" rowsep="0" headers="t5606h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC72" nameend="2" colsep="0" rowsep="0" headers="t5606h1">Home Trade Class I or II;</entry></row><row topmarginspacing="4"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5606h0"></entry><entry namest="COLSPEC74" nameend="2" colsep="0" rowsep="0" headers="t5606h1">“Group 2 ship” means a ship certificated to carry more than 12 passengers that is on a voyage as follows:</entry></row><row topmarginspacing="4"><entry colsep="0" rowsep="0" headers="t5606h0"></entry><entry colsep="0" rowsep="0" headers="t5606h1"></entry><entry colsep="0" rowsep="0" headers="t5606h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC72" nameend="2" colsep="0" rowsep="0" headers="t5606h1">Home Trade Class III to ports outside Canada,</entry></row><row topmarginspacing="4"><entry colsep="0" rowsep="0" headers="t5606h0"></entry><entry colsep="0" rowsep="0" headers="t5606h1"></entry><entry colsep="0" rowsep="0" headers="t5606h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC72" nameend="2" colsep="0" rowsep="0" headers="t5606h1">where the ship is over 150 tons gross tonnage, Inland Water Class I or II to ports outside Canada, and</entry></row><row topmarginspacing="4"><entry colsep="0" rowsep="0" headers="t5606h0"></entry><entry colsep="0" rowsep="0" headers="t5606h1"></entry><entry colsep="0" rowsep="0" headers="t5606h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC72" nameend="2" colsep="0" rowsep="0" headers="t5606h1">where the ship is over 61 m length,</entry></row><row topmarginspacing="4"><entry colsep="0" rowsep="0" headers="t5606h0"></entry><entry colsep="0" rowsep="0" headers="t5606h1"></entry><entry colsep="0" rowsep="0" headers="t5606h1"></entry><entry colsep="0" rowsep="0" headers="t5606h1">(i)</entry><entry colsep="0" rowsep="0" headers="t5606h1">Home Trade Class III to Canadian ports only,</entry></row><row topmarginspacing="4"><entry colsep="0" rowsep="0" headers="t5606h0"></entry><entry colsep="0" rowsep="0" headers="t5606h1"></entry><entry colsep="0" rowsep="0" headers="t5606h1"></entry><entry colsep="0" rowsep="0" headers="t5606h1">(ii)</entry><entry colsep="0" rowsep="0" headers="t5606h1">Inland Water Class I or II to Canadian ports only, or</entry></row><row topmarginspacing="4"><entry colsep="0" rowsep="0" headers="t5606h0"></entry><entry colsep="0" rowsep="0" headers="t5606h1"></entry><entry colsep="0" rowsep="0" headers="t5606h1"></entry><entry colsep="0" rowsep="0" headers="t5606h1">(iii)</entry><entry colsep="0" rowsep="0" headers="t5606h1">Minor Waters Class I;</entry></row><row topmarginspacing="4"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5606h0"></entry><entry namest="COLSPEC74" nameend="2" colsep="0" rowsep="0" headers="t5606h1">“Group 3 ship” means any passenger and non-passenger ship over 18 m in length that is not a Group 1 or a Group 2 ship;</entry></row><row topmarginspacing="4"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5606h0"></entry><entry namest="COLSPEC74" nameend="2" colsep="0" rowsep="0" headers="t5606h1">“Group 4 ship” means a ship that is over 5 tons gross tonnage, does not exceed 18 m in length and is not a launch;</entry></row><row topmarginspacing="4" bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5606h0"></entry><entry namest="COLSPEC74" nameend="2" colsep="0" rowsep="0" headers="t5606h1">“Group 5 ship” means a ship that is</entry></row><row topmarginspacing="4" bottommarginspacing="2"><entry colsep="0" rowsep="0" headers="t5606h0"></entry><entry colsep="0" rowsep="0" headers="t5606h1"></entry><entry colsep="0" rowsep="0" headers="t5606h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC72" nameend="2" colsep="0" rowsep="0" headers="t5606h1">not over five tons gross tonnage and certificated to carry passengers; or</entry></row><row topmarginspacing="4" bottommarginspacing="2"><entry colsep="0" rowsep="0" headers="t5606h0"></entry><entry colsep="0" rowsep="0" headers="t5606h1"></entry><entry colsep="0" rowsep="0" headers="t5606h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC72" nameend="2" colsep="0" rowsep="0" headers="t5606h1">is a launch.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division ii</Label><TitleText>Groups 1, 2 and 3 Ships</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.30*" htmlwidth="10%" /><colspec colname="COLSPEC76" colwidth="7.47*" htmlwidth="7%" /><colspec colname="COLSPEC75" colwidth="89.43*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5607h0">Item</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="1" valign="bottom" id="t5607h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h0 t5607h1"><Emphasis style="italic">Pumping Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">1.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Water shall be prevented from inadvertently passing from</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">water-containing spaces or the sea into cargo or machinery spaces; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">from one compartment to another.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">2.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Piping systems shall be arranged as follows:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">the bilge pipe connection to a pump that has suction from the sea shall include either a screw-down non-return valve or a cock that cannot be open to the bilges and to the water-containing spaces or the sea at the same time; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">an arrangement of lock-up valves or blank flanges shall be provided to prevent any deep tank from being inadvertently filled from the sea when containing cargo or pumped out through a bilge pipe when containing ballast water and explanatory notices shall be conspicuously displayed near the components involved.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">3.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Screw-down non-return valves shall be fitted in the following components:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">bilge valve distribution manifolds;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">bilge suction hose connections, where fitted directly to the pump or to the main bilge suction pipe; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">direct bilge suction pipes and bilge pump connections to the main bilge suction pipe.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">4.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">All cocks and valves that are connected to bilge and ballast pipes shall be fitted with legible name-plates and shall be in readily accessible positions.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">5.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">For ships, other than tankers and similar ships, branch bilge suction pipes shall be connected to the main bilge suction pipes and shall be arranged to draw water from any cargo hold, tunnel, machinery space or similar compartment, except that in chain lockers and other small spaces independent pumps that are power or manually driven may be used.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">6.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Subject to items 7 and 118 to 121, bilge suction pipes that are required for drawing water from cargo or machinery spaces shall be entirely separate from sea inlet pipes or from pipes that may be used for filling or emptying spaces where water or oil is carried.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">7.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The following connections may be used in bilge suction systems:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">a connecting pipe to a bilge water ejector, where the bilge water ejector provides a service equivalent to a pump;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">a connecting pipe from a pump to its suction valve manifold; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">a deep tank suction pipe suitably connected through a change-over device to the bilge, ballast or oil-pumping system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">8.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Ballast water shall not be carried in tanks intended for fuel oil unless required for the stability of the ship or other safety reasons.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">9.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where tanks, including passive roll-stabilizing tanks, are arranged for alternative carriage of oil, water or dry cargo, there shall be blank flanging or other suitable arrangements to prevent interconnection of pumping, overflow or liquid heating systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">10.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Bilge suction pipes shall not be carried through double bottom tanks unless alternative routing is impracticable.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">11.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Bilge suction pipes that pass through double bottom tanks shall be of extra-heavy thickness.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">12.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Bilge suction pipes that pass through deep tanks shall be led through pipe tunnels, but where such leading is not practicable, the pipes shall be of extra-heavy thickness and fitted in one length if practicable, with welded or heavily flanged joints.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">13.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Provision for expansion of pipes shall be made and within tanks expansion bends only shall be fitted.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">14.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The open ends of the bilge suction pipes in the holds shall be fitted with non-return valves suitable for use in cargo holds.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">15.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The distance between the lower end of all bilge suction tailpipes and the bottom of the bilge or well shall be adequate to allow a full flow of water and to facilitate cleaning.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">16.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Bilge and ballast suction and discharge pipes shall be made in readily removable lengths with flanged joints, except as prescribed in item 12, and shall be efficiently secured in position to prevent chafing or movement.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">17.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Long or heavy lengths of pipes shall be supported by bearers so that no undue load will be carried by the flanged connections of the pumps or fittings to which the flanged connections are attached.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">18.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Subject to subitem 9(<Emphasis style="italic">c</Emphasis>) of Division II of Part I of Schedule IX, pipes for bilge, ballast and similar systems shall be made of steel or other metallic material.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">19.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Piping, valves, mud boxes, strainers and extended spindles, where fitted, shall be protected against damage, particularly in cargo holds where spindles shall be encased.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">20.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Shipside connections shall be designed, constructed and installed in accordance with rules or codes and Schedule VII.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h0 t5607h1"><Emphasis style="italic">Machinery Space Normal Bilge Pumping</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">21.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The machinery space bilge-water means of drainage for normal bilge pumping shall be such that any water that enters the space can be pumped out through at least two bilge suction pipes when the ship is on an even keel and is either upright or is listing by not more than 5°.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">22.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">One of the suction pipes shall be a branch bilge suction pipe leading from the main bilge suction pipe and the other shall be a direct bilge suction pipe leading directly from an independent power pump that may be used independently of the main bilge suction piping system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">23.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where the double bottom extends the full length of the machinery space and forms bilges at the sides of the machinery space, one branch bilge suction pipe and one direct bilge suction pipe shall lead to each side bilge.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">24.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where the double bottom extends the full length and breadth of the machinery space and is fitted with bilge wells, one branch bilge suction pipe and one direct bilge suction pipe shall lead to each of the two bilge wells having a capacity of not less than 150 L and situated one at each side of the machinery space.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">25.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where there is no double bottom, one branch bilge suction pipe and one direct bilge suction pipe shall lead to accessible locations as near to the centre line of the ship as practicable and, if the rise of the floor is less than 5°, a branch bilge suction pipe shall lead to each side of the machinery space.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">26.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">In ships certificated to carry more than 12 passengers, the machinery spaces bilge water drainage shall be such that the spaces, where practicable, can be pumped out after a casualty, whether the ship is upright or listed.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">27.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">For ships referred to in item 26 there shall be a direct bilge suction pipe from each independent bilge pump situated in the machinery spaces except that not more than two direct suction pipes, one on the port side and one on the starboard side, are required to be fitted in each machinery space.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">28.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Bilge suction pipes shall lead to the forward sides of the machinery spaces where the bilge-water normally drains forward.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">29.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where a considerable quantity of cooling water is discharged to the machinery space bilges, means shall be provided to deal with that water in addition to the normal bilge-pumping arrangements where the normal bilge-pumping capacity is inadequate to deal with the additional water.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">30.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where there are depressions in the tank tops due to inverse camber, double bottom discontinuity or accommodation for machinery, means shall be provided to remove bilge-water accumulation in the depressions.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">31.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where the main propulsion system is electrical, means shall be provided to prevent accumulation of bilge-water under the main propulsion generators and motors.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">32.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where a machinery space is divided by watertight bulkheads so as to separate the boiler rooms or auxiliary engine rooms from the main engine room, the number and position of the branch bilge suction pipes in the boiler rooms or auxiliary engine rooms shall be the same as for cargo holds referred to in item 49 except that an additional independent power pump direct bilge suction pipe shall be fitted in each watertight compartment and shall, if practicable, lead to the end of the compartment opposite the branch suction pipe location.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">33.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Provisions similar to those set out in item 32 shall be made in each separate motor room of electrically propelled ships.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">34.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The shaft tunnel aft well suction pipe shall be directly connected to the main bilge suction pipe.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">35.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where the tank top in the shaft tunnel slopes down from aft to forward, a bilge well shall be provided at the forward end of the tunnel in addition to the aft well referred to in item 34 and one suction pipe may serve both wells if the wells are fitted with separate valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">36.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Suction pipes for normal bilge pumping in machinery spaces and shaft tunnels shall lead from easily accessible mud boxes fitted with</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">straight tailpipes to bilges; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">covers that are secured in such a manner that they can be expeditiously opened and closed.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">37.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Subject to item 38, strainers shall not be fitted to the lower ends of tailpipes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">38.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">In the case of ships with open floors, strainers with an open area at least three times the area of the suction pipe may be fitted at the lower ends of tail pipes in lieu of mud boxes if the strainers can be fitted in readily accessible locations.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">39.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Bilge cocks, valves and mud boxes shall be fitted at or above the machinery space and shaft tunnel platforms.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">40.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where it is not practicable to avoid locating bilge cocks, valves and mud boxes at the engine control platform or in passageways, the bilge cocks, valves and mud boxes may be situated just below the platform if readily removable traps or covers are fitted with name-plates indicating the presence of components.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h0 t5607h1"><Emphasis style="italic">Emergency Bilge Pumping of Machinery Spaces</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">41.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">In addition to the bilge suction pipes required for normal bilge pumping referred to in items 21 to 40, every machinery space shall be fitted with an emergency bilge suction pipe which pipe shall be</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">led to the main cooling-water pump from a suitable drainage level in the machinery space; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">fitted with a screw-down non-return valve that has a spindle extended so that the hand wheel is not less than 460 mm above the bottom platform.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">42.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where two or more cooling-water pumps are provided, each capable of supplying cooling water for normal propulsion power, only one pump is required to be fitted with an emergency bilge suction pipe.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">43.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">In ships with steam-propelled machinery, the emergency bilge suction pipe shall have a diameter of at least two-thirds that of the cooling-water suction pipe connection to the pump, and in other ships, the emergency bilge suction pipe shall have the same diameter as the cooling-water suction pipe connection to the pump.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">44.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where the main cooling-water pump referred to in subitem 41(<Emphasis style="italic">a</Emphasis>) is less suitable than other available pumps for bilge pumping duties, an emergency bilge suction pipe separate from, and additional to, any other required bilge suction pipe shall be fitted to draw water from the drainage level of a machinery space, and shall</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">lead to the largest available independent power pump; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">have the same diameter as the largest suction pipe connection to the pump referred to in subitem (<Emphasis style="italic">a</Emphasis>).</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">45.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Except in ships certificated to carry more than 12 passengers, a direct bilge suction pipe on the same side of the ship as the emergency suction pipe may be omitted where the emergency bilge suction pipe is connected to a self-priming type of pump.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">46.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Emergency bilge suction valve name-plates shall be permanently marked “For emergency use only”.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">47.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">A flexible suction hose that has a strainer attached to its lower end and that is of sufficient length and diameter that it is capable of being connected to the suction side of an independent power pump shall be located in the boiler room of every coal-burning ship.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h0 t5607h1"><Emphasis style="italic">Bilge Pumping of Cargo Holds, Tanks and Other Non-machinery Spaces</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">48.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">An efficient pumping system shall be fitted with bilge suction pipes at suitable drainage levels and located so that all water within any compartment, other than spaces permanently appropriated for the carriage of oil, fresh water or other liquids, can be pumped out through at least one suction pipe when the ship is on an even keel and is either upright or is listing by not more than 5°.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">49.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">For the purposes of item 48, suction pipes on each side of the ship are necessary, except in short narrow compartments where one suction pipe can provide effective drainage under the conditions set out in that item.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">50.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">In ships certificated to carry more than 12 passengers, the drainage flow arrangements to bilge suction pipes shall be such that all watertight compartments, where practicable, can be pumped out after a casualty, whether the ship is upright or listing.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">51.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The open ends of bilge suction pipes in holds and other compartments outside machinery spaces and shaft tunnels shall be enclosed in strainers that</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">have perforations not more than 10 mm in diameter;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">have a total perforated area of not less than twice that of the suction pipe; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">can be cleared without breaking any joint of the suction pipe.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">52.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where, due to size or location of a particular compartment, the installation of a bilge suction pipe would be impracticable, and where flooding calculations indicate that the safety of the ship will not be impaired, the installation of a bilge suction pipe is not required to be installed in that compartment.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">53.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Subject to item 118, in ships that have only one cargo hold, where the cargo hold is over 30 m in length bilge suction pipes shall lead to suitable positions in the aft half length and in the forward half length of the cargo hold.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">54.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where close-fitting ceilings or continuous plates are fitted over side bilges, arrangements shall be made so that water in a hold compartment can find its way to the bilge suction pipes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">55.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where the inner bottom plating extends to the side of the ship, the bilge suction pipes shall lead to wells placed at the side, and if the tank top plating has inverse camber, a suction pipe shall also lead to a well fitted at the centre line of the ship.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">56.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Bilge wells shall have a capacity of not less than 150 L, except that in small compartments bilge wells are not required to be fitted if the bilge suction pipes have steel strainers fitted at their lower end.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">57.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where access openings to bilge wells are necessary, they shall be fitted as near to the suction strainers as practicable.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">58.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Access to the bilge suction strainer of a hold well shall not be by means of an opening in machinery space or shaft tunnel watertight divisions, except that where such an arrangement is necessary due to the design features and location of the hold bilge well, the watertight access opening cover shall be of the hinged type, and a permanent metal instruction plate that bears a notice that the cover must be kept closed, except when access is necessary, shall be affixed in a well-lighted position.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">59.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">In ships certificated to carry more than 12 passengers, an access opening shall not pass through the machinery space or shaft tunnel watertight divisions.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">60.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Subject to item 61, the intactness of machinery space or shaft tunnel watertight divisions shall not be impaired by fitting scupper pipe discharges into machinery spaces or shaft tunnels from adjacent compartments situated below the bulkhead deck.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">61.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Scupper pipes with valves and that lead from adjacent compartments may be fitted and lead into a strongly constructed scupper drain tank situated in a machinery space or tunnel.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">62.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The scupper drain tank shall be entirely closed and shall be</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">drained by means of a suction pipe leading from the main bilge pipe through a screw-down non-return valve; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">vented from a position above the bulkhead deck.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">63.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Means shall be provided for determining the level of water in the scupper drain tank.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">64.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where one drain tank is used for the drainage of several watertight compartments, the scupper pipes shall be fitted with screw-down non-return valves.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">65.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Means shall be provided for the efficient drainage of the inside of all refrigerated spaces in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">66.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Means shall be provided for the drainage of the chain locker and watertight compartments above the forepeak tank by manual or power pumps.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">67.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Steering gear compartments or other small enclosed spaces situated above the afterpeak tank shall be provided with suitable means of drainage by manual or power pumps.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">68.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where the compartments referred to in item 67 are adequately isolated from the adjacent ‘tween-decks, they may be drained by scupper pipes of not less than 35 mm internal diameter discharging to the shaft tunnel, or to machinery spaces in the case of ships with machinery aft, if the pipes are fitted with self-closing cocks situated in well-lighted and visible locations.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">69.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">In ships certificated to carry more than 12 passengers, the scupper pipe arrangement referred to in item 68 shall not be fitted unless flooding calculations indicate that the safety of the ship will not be impaired.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h0 t5607h1"><Emphasis style="italic">Forepeak and Afterpeak Pumping</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">70.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where the forepeak and afterpeak are used as tanks, a separate power pump suction pipe shall lead to each tank, except that in the case of small tanks used for the carriage of domestic fresh water, manual pumps may be used.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">71.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where the forepeak and afterpeak are not used as tanks and power bilge pumping system suction pipes are not fitted, pumping of both peaks may be effected by manual pumps if the suction lift is well within the capacity of the pumps and does not exceed 7.5 m in height.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">72.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The collision bulkhead may be pierced by pipes for tank filling and emptying purposes but no open-ended drain valve or cock shall be fitted.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">73.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The pipes referred to in item 72 shall be provided with screw-down valves that are secured to the bulkhead inside the forepeak and that are</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">capable of being operated from an accessible location above the bulkhead deck; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">clearly identified with an indication of their operational status.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">74.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">In ships certificated to carry 12 passengers or less, valves referred to in item 73 may be fitted on the aft side of the collision bulkhead and the valves are not required to be capable of remote control if</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">they are readily accessible at all times; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">the space in which they are located is not a cargo space.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h0 t5607h1"><Emphasis style="italic">Watertight Division Components</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">75.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">No open-ended drain valve or cock shall be fitted to any watertight division where alternative means of drainage are practicable.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">76.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where fitted, open-ended drain valves and cocks shall be</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">readily accessible at all times;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">capable of being shut-off from locations above the bulkhead deck; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">clearly identified with an indication of their operational status.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">77.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Valves, cocks, pipes or other components attached directly to the plating of tanks and to watertight divisions shall be secured by</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">screwing studs through the plating;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">using screwed bolts and not by bolts passing through clearance holes; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">welding the studs or the bulkhead piece to the plating.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h0 t5607h1"><Emphasis style="italic">Tank Venting Pipes</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">78.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Vent pipes shall be provided for tanks intended to contain liquid.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">79.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Vent pipes shall be arranged to be self-draining when the ship is on an even keel.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">80.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Vent pipes shall be arranged, and the upper part of tanks designed, so that air or gas can freely evacuate.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">81.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Vent pipes shall be fitted at the highest parts of the tanks and, where possible, opposite the filling pipes, when the ship is to be on an even keel.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">82.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">When the tank top is of irregular form, the number and location of vent pipes shall be such as to permit the efficient ventilation of the tank.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">83.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where only one vent pipe is provided, it shall not be used as filling pipe.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">84.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Vent pipes from double-bottom tanks, deep tanks and other tanks that can be filled from the sea shall lead to above the freeboard deck.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">85.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Vent pipes from compartments such as cofferdams and from all tanks that can be pumped shall not lead to enclosed areas of the ship.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">86.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Means shall be provided to prevent over-pressure or a vacuum in the tanks when closing appliances are in place, by a hole approximately 10 mm in diameter, or other suitable means, in the closing appliance or vent pipe bend.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">87.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">In each tank that is capable of being pumped up and in which no over-flow pipe is fitted, the total cross-section of vent pipes shall not be less than 1.25 times the cross-sectional area of the corresponding filling pipes and the internal diameter shall not be less than 50 mm.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">88.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Vent pipes from heeling or trimming pumping system tanks shall be of sufficient size to prevent the tanks from being subjected to a vacuum or over-pressure beyond the designed structural strength of the tanks when the systems are in operation.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">89.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Permanent name-plates shall be attached to the upper part of vent pipes.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h0 t5607h1"><Emphasis style="italic">Overflow Pipes</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">90.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where necessary, overflow pipes shall be fitted to prevent tanks from being subjected during filling operations to pressures greater than test pressures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">91.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Overflow pipes shall be fitted where the cross-section of the vent pipes is less than that set out for vent pipes in item 87.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">92.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Overflow pipes shall have name-plates attached to the upper part and shall be led</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">to areas other than enclosed areas of the ship; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">to spaces provided with means for evacuating the liquid likely to escape accidentally from the overflow.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">93.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where overflow pipes from tanks containing the same liquid or from tanks each of which contains a different liquid are connected to a common piping system, provision shall be made to prevent any risk of intercommunication between the tanks while the tanks are being emptied or filled.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">94.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Arrangements shall be made so that a tank cannot be flooded from the sea through the overflow pipe where another tank connected to the same overflow pipe system is bilged.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">95.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Overflow piping systems shall be so arranged as to be self-draining when the ship is on an even keel.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">96.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The internal diameter of overflow pipes shall not be less than 50 mm.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h0 t5607h1"><Emphasis style="italic">Sounding Arrangements</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">97.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Means shall be provided for sounding all tanks and the bilges of those compartments which are not readily accessible and the soundings shall be taken as near to the suction pipes as practicable.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">98.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Bilges of compartments that are not readily accessible shall be fitted with sounding pipes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">99.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Sounding pipes shall have an identifying name-plate attached to the upper end, be as straight as practicable, and if curved to suit the structure of the ship, the curvature shall be sufficiently easy to permit the ready passage of the sounding rod or chain.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">100.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Suitable sounding devices may be used in lieu of sounding pipes for tank liquid level gauging if a supplementary means of manual sounding is provided.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">101.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Subject to items 102 and 104, sounding pipes shall lead to locations above the bulkhead deck that are accessible at all times.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">102.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">In machinery spaces and shaft tunnels where it is not practicable to extend the sounding pipes from double-bottom tanks to above the bulkhead deck, short sounding pipes extending to readily accessible locations at the lowest working-level platform may be fitted.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">103.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Short sounding pipes to water tanks shall be fitted with shut-off cocks or with screw caps attached to the pipes by chains.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">104.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">In ships certificated to carry more than 12 passengers, short sounding pipes may be fitted to cofferdams and double-bottom water tanks situated in the machinery spaces only and shall in all cases to be fitted with self-closing cocks.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">105.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Sounding pipes with elbows shall not be fitted to deep tanks unless the pipes and elbows are situated within closed cofferdams or within tanks containing liquids similar to the liquids in the pipes and elbows, but sounding pipes with elbows may be fitted to tanks other than deep tanks and may be used for sounding compartment bilges if it is not practicable to lead sounding pipes directly to the tanks or compartments.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">106.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The elbows of sounding pipes shall be of heavy construction and adequately supported.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">107.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">In ships certificated to carry more than 12 passengers, sounding pipes with elbows shall not be fitted.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">108.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Striking plates of adequate thickness and size shall be fitted under open-ended sounding pipes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">109.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where slotted sounding pipes having closed ends are used, the closing plugs shall be of heavy construction.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">110.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The internal diameter of sounding pipes shall be not less than 30 mm.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">111.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">All sounding pipes for compartments or tanks that pass through refrigerated spaces, or the insulation thereof, and in which the temperature is 0°C or below, shall be suitably insulated and the internal diameter of the pipes shall not be less than 65 mm.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h0 t5607h1"><Emphasis style="italic">Bilge Piping</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">112.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Subject to items 113 to 118 and to items 7 and 8 of Division VI, the internal diameter of main and branch bilge suction pipes shall be in accordance with rules or codes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">113.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">For all ships certificated to carry more than 12 passengers that have a subdivision load line, the diameter of the main bilge pipe shall not be less than that derived in accordance with the following formula, taken to the nearest 5 mm:</entry></row><row><entry colsep="0" rowsep="0" headers="t5607h0"></entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1"><Provision first-line-indent="0" subsequent-line-indent="0"><FormulaGroup><Formula><ImageGroup position="center" width="11pc"><AlternateText>Lowercase d equals 25 millimeters plus 1.68 times the square root of the product of L times the sum of B and uppercase D</AlternateText><Image source="SOR-90-264img\SOR-90-264_e001.png" /></ImageGroup></Formula><FormulaConnector>where</FormulaConnector><FormulaDefinition><FormulaTerm>d</FormulaTerm><Text>is the internal diameter of the bilge pipe, in millimetres</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>L</FormulaTerm><Text>is the distance measured between perpendiculars of the ship taken at the extremities of the deepest subdivision load line, in metres</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>B</FormulaTerm><Text>is the breadth of the ship measured at the extreme width from outside of frame to outside of frame at or below the deepest subdivision load line, in metres</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>D</FormulaTerm><Text>is the moulded depth of the ship to the bulkhead deck, in metres</Text></FormulaDefinition></FormulaGroup></Provision></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">114.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The internal diameter of the main bilge suction pipe shall not be less than that of any branch bilge suction pipe and for Group 1 and 2 ships the internal diameter of the main bilge suction pipe shall not be less than 60 mm.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">115.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The internal diameter of the branch bilge suction pipe shall not be less than 50 mm and is not required to be more than 100 mm except in the case of pumping from small spaces, where piping with a diameter of 35 mm or more may be used.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">116.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The internal diameter of the bilge suction pipe to the shaft tunnel well shall not be less than 60 mm except in ships not exceeding 61 m in length, where the internal diameter may not be less than 50 mm.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">117.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Notwithstanding item 114, for ships not exceeding 31 m in length certificated to operate on Minor Waters, Inland Waters Class II or Home Trade Class IV voyages, the diameter of the main and branch bilge suction pipes may be reduced by 20 per cent below the diameter determined in accordance with item 112, but the internal diameter shall not be less than 35 mm.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">118.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">For a Group 3 ship that has only one cargo hold, where the hold is over 30 m in length one branch suction pipe only may lead to each side of the after end of the cargo hold if the ship</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">is certificated to operate solely on Inland Waters Class voyages;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">has double-bottom tanks under the full length and breadth of the cargo hold;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">has watertight longitudinal bulkheads on both sides of the hold that extend the full length of the hold and extend from the bottom of the ship to the freeboard deck; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">is designed so that any water in the hold will drain to at least one of the suction pipes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">119.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The diameter of the branch suction pipe referred to in item 118 shall not be less than that derived in accordance with the following formula, taken to the nearest 5 mm:</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1"><Provision first-line-indent="0" subsequent-line-indent="0"><FormulaGroup><Formula><ImageGroup position="center" width="11pc"><AlternateText>Lowercase d equals 25 millimeters plus 2.16 times the square root of the product of C times the sum of B and uppercase D</AlternateText><Image source="SOR-90-264img\SOR-90-264_e002.png" /></ImageGroup></Formula><FormulaConnector>where:</FormulaConnector><FormulaDefinition><FormulaTerm>d</FormulaTerm><Text>is the internal diameter of the branch suction pipe, in millimetres</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>C</FormulaTerm><Text>is the length of the cargo hold, in metres</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>B</FormulaTerm><Text>is the greatest moulded breadth of the ship in metres</Text></FormulaDefinition><FormulaDefinition><FormulaTerm>D</FormulaTerm><Text>is the moulded depth of the ship to freeboard deck, in metres</Text></FormulaDefinition></FormulaGroup></Provision></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">120.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where the branch suction pipe referred to in item 118 is used only for the purpose of pumping from the cargo hold, it may be connected to the main bilge pipe or the main ballast pipe, but in such a case</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">the internal diameter of the main pipe shall not be less than the diameter of the branch suction pipe;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">the appropriate power pump shall have the pumping capacity for the diameter of the main pipe as set out in the Table of Capacities to this Part; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">the branch suction pipe shall be fitted with a screw-down non-return valve.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">121.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where the branch suction pipe referred to in item 118 is used for the purpose of pumping from and filling the cargo hold, it shall be connected to the main ballast pipe, and in such case</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">the internal diameter of the main ballast pipe shall not be less than the diameter of the branch suction pipe;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">the ballast pump shall have the pumping capacity for the diameter of the main ballast pipe as set out in the Table of Capacities to this Part; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0"></entry><entry colsep="0" rowsep="0" headers="t5607h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colsep="0" rowsep="0" headers="t5607h1">the branch suction pipe shall be fitted with a screw lift valve and means to prevent the cargo hold from being inadvertently filled from the sea.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">122.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">The cross-sectional area of each pipe connecting the main bilge pipe to a bilge distribution manifold shall not be less than the sum of the cross-sectional areas of the two largest branch bilge suction pipes connected to the manifold, but need not be greater than the cross-sectional area of the main bilge pipe.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">123.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Subject to item 124, the diameter of direct bilge suction pipes in machinery spaces, other than emergency suction pipes, shall have a diameter not less than the diameter of the main bilge pipe.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">124.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">For Group 3 ships, where direct bilge suction pipes lead to both sides of the ship for normal bilge pumping, one suction pipe shall be of a size not less than that of the main bilge pipe and the other suction pipe may be of the size of the machinery space branch bilge suction pipe, but the smaller suction pipe shall be fitted on the same side as the emergency bilge suction pipe.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h0 t5607h1"><Emphasis style="italic">Bilge Pumps and Connections</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">125.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">All power pumps essential for bilge pumping shall be of the self-priming type unless a central priming system is provided for those pumps.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">126.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Each power bilge pump shall be capable of giving a flow rate of water through the required main bilge pipe of not less than 2 m/s as set out in the Table of Capacities to this Part.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">127.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Bilge pumps may be used as fire pumps if the simultaneous operation of bilge-pumping systems and fire-pumping systems is not compromised.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">128.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Sanitary, ballast and general service pumps may be used as independent power bilge pumps if they are fitted with the necessary connections for bilge pumping.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">129.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">No emergency bilge pump shall be installed forward of the collision bulkhead.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">130.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Pumps required for essential services shall not be connected to a common suction manifold, a common suction pipe, a common discharge manifold or a common discharge pipe unless the arrangements are such that the working of any pump so connected will not be affected by any other pumps operating at the same time.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">131.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Bilge pumps shall have isolating valves so that any one pump may continue to operate when another pump is dismantled.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">132.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">Where relief valves are fitted to bilge pumps that have sea connections, those valves and their outlets shall be fitted in readily visible locations above the lowest working-level platform.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5607h0">133.</entry><entry namest="COLSPEC76" nameend="COLSPEC75" colsep="0" rowsep="0" headers="t5607h1">In ships certificated to carry more than 12 passengers, power bilge pumps located in spaces other than machinery spaces are required to have separate direct suction pipes unless the size of the other spaces does not warrant such pipes.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division III</Label><TitleText>Group 1 Ships</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC0" colwidth="7.55*" htmlwidth="7%" /><colspec colname="2" colwidth="92.50*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5608h0">Item</entry><entry namest="COLSPEC0" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5608h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5608h0 t5608h1"><Emphasis style="italic">Bilge Pumps and Connections</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5608h0">1.</entry><entry namest="COLSPEC0" nameend="2" colsep="0" rowsep="0" headers="t5608h1">The main bilge pipe shall be connected to</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5608h0"></entry><entry colsep="0" rowsep="0" headers="t5608h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5608h1">at least three power pumps, where the Criterion of Service Numeral for the ship, as determined pursuant to the <XRefExternal reference-type="regulation" link="C.R.C.,_c._1431">Hull Construction Regulations</XRefExternal>, is less than 30; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5608h0"></entry><entry colsep="0" rowsep="0" headers="t5608h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5608h1">at least four power pumps, where the Criterion of Service Numeral for the ship, as determined pursuant to the <XRefExternal reference-type="regulation" link="C.R.C.,_c._1431">Hull Construction Regulations</XRefExternal>, is 30 or more.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5608h0">2.</entry><entry namest="COLSPEC0" nameend="2" colsep="0" rowsep="0" headers="t5608h1">One of the power pumps referred to in item 1 may be directly driven by a main propulsion engine.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division IV</Label><TitleText>Group 2 Ships</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC1" colwidth="7.55*" htmlwidth="7%" /><colspec colname="2" colwidth="92.50*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5609h0">Item</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5609h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5609h0 t5609h1"><Emphasis style="italic">Bilge Pumps and Connections</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5609h0">1.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5609h1">The main bilge pipe shall be connected to</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5609h0"></entry><entry colsep="0" rowsep="0" headers="t5609h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5609h1">at least three power pumps, where the Criterion of Service Numeral for the ship, as determined pursuant to the <XRefExternal reference-type="regulation" link="C.R.C.,_c._1431">Hull Construction Regulations</XRefExternal>, is less than 30; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5609h0"></entry><entry colsep="0" rowsep="0" headers="t5609h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5609h1">at least four power pumps, where the Criterion of Service Numeral for the ship, as determined pursuant to the <XRefExternal reference-type="regulation" link="C.R.C.,_c._1431">Hull Construction Regulations</XRefExternal>, is 30 or more.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5609h0">2.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5609h1">One of the power pumps referred to in item 1 may be directly driven by a main propulsion engine.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5609h0">3.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5609h1">In ships of less than 91.5 m in length certificated to operate on Minor Waters Class I voyages, the number of pumps set out in item 1 may be reduced by one.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5609h0">4.</entry><entry namest="COLSPEC1" nameend="2" colsep="0" rowsep="0" headers="t5609h1">In ships of less than 61 m in length certificated to operate on voyages other than Minor Waters Class I voyages, the number of pumps set out in item 1 may be reduced by one if one manual pump having inlet and outlet sizes equal to or greater than those of the pump it is replacing is provided.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division V</Label><TitleText>Groups 1 and 2 Ships</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="12.88*" htmlwidth="10%" /><colspec colname="COLSPEC3" colwidth="8.45*" htmlwidth="7%" /><colspec colname="COLSPEC2" colwidth="9.23*" htmlwidth="7%" /><colspec colname="2" colwidth="93.26*" htmlwidth="75%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5610h0">Item</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5610h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">1.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">In ships of 91.5 m or more in length, or that have a Criterion of Service Numeral for the ship, as determined pursuant to the <XRefExternal reference-type="regulation" link="C.R.C.,_c._1431">Hull Construction Regulations</XRefExternal>, of 30 or more, the bilge pumping system shall have at least one power pump available for use in all flooding conditions the ship is designed to withstand.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">2.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">The requirement of item 1 is met where</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0"></entry><entry colsep="0" rowsep="0" headers="t5610h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5610h1">one of the power pumps is an emergency pump of a submersible type having a source of power and controls located above the bulkhead deck; or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0"></entry><entry colsep="0" rowsep="0" headers="t5610h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5610h1">the pumps and their sources of power are so disposed throughout the length of the ship that under any flooding conditions that the ship is designed to withstand at least one power pump in an undamaged compartment is operable.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">3.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">Controls referred to in subitem 2(<Emphasis style="italic">a</Emphasis>) shall be clearly identified and an indication of their operational status at the remote control location given, and where extended spindles are used for valves, the spindles shall lead as directly as possible to the remote control location.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">4.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">Where the ship is not a Safety Convention ship, one power pump, other than the emergency pump, with a pumping capacity of not less than 70 per cent of the capacity set out in the Table of Capacities to this Part may be used where the deficiency in pumping capacity is made up by the excess capacity in the other power pumps.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">5.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">The required power pump capacity in m<Sup>3</Sup> per hour for a given internal diameter in millimetres of main bilge pipes is set out in the Table of Capacities to this Part.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">6.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">Where practicable, the power bilge pumps shall be placed in separate watertight compartments so arranged or situated that those compartments will not readily be flooded by the same casualty.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">7.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">Where the engines and boilers are in two or more watertight compartments, the pumps available for bilge service shall be distributed throughout the compartments to the extent possible.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">8.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">Manual bilge pumps, where fitted, shall be operable from above the bulkhead deck and shall be so arranged that the components can be withdrawn for examination and overhaul during flooding.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">9.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">Where two manual pumps are fitted, a shut-off valve or cock operated from above the bulkhead deck, or non-return valves, shall be fitted to enable one of the pumps to be dismantled without the efficiency of the other being affected.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">10.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">In coal-burning ships where there is no watertight bulkhead between the engine room and the boiler room, a direct discharge overboard shall be fitted from at least one condenser circulating water pump, or a condenser by-pass shall be fitted to the circulating water pipeline.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">11.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">The main bilge pipe shall be arranged so that no part is situated nearer the side of the ship than the B/5 line where B is the breadth of the ship measured at right angles to the centre line at the level of the deepest subdivision load line or deep load line where a subdivision load line is not assigned.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">12.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">Where any bilge pump or its connecting pipe to the main bilge pipe is situated outboard of the B/5 line,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0"></entry><entry colsep="0" rowsep="0" headers="t5610h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5610h1">a non-return valve shall be fitted in the connecting pipe at the junction with the main bilge pipe; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0"></entry><entry colsep="0" rowsep="0" headers="t5610h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5610h1">the emergency bilge pump and its connections to the main bilge pipe shall be arranged so that they are situated inboard of the B/5 line.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">13.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">Means shall be provided to prevent the compartment served by any bilge suction pipe from being flooded in the event of the pipe being severed or otherwise damaged in any other compartment by collision or grounding.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">14.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">For the purpose of item 13, where any part of a bilge suction pipe is situated outboard of the B/5 line or in a duct keel, a non-return valve shall be fitted to the pipe in the compartment containing an open end.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">15.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">All distribution boxes, cocks and valves in bilge pumping systems shall be</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0"></entry><entry colsep="0" rowsep="0" headers="t5610h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5610h1">in locations that are accessible at all times under normal circumstances; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0"></entry><entry colsep="0" rowsep="0" headers="t5610h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5610h1">so arranged that one of the bilge pumps is capable of pumping out any compartment during flooding conditions.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">16.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">Where there is only one system of pipes common to all the bilge pumps, the necessary cocks or valves for controlling the bilge suction shall be operable from above the bulkhead deck.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">17.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">Where, in addition to the main bilge pumping system, an emergency bilge pumping system is fitted,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0"></entry><entry colsep="0" rowsep="0" headers="t5610h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5610h1">the emergency system shall be</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0"></entry><entry colsep="0" rowsep="0" headers="t5610h1"></entry><entry colsep="0" rowsep="0" headers="t5610h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5610h1">independent of the main system, and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0"></entry><entry colsep="0" rowsep="0" headers="t5610h1"></entry><entry colsep="0" rowsep="0" headers="t5610h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5610h1">so arranged that a pump is capable of pumping out any compartment during flooding; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0"></entry><entry colsep="0" rowsep="0" headers="t5610h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC2" nameend="2" colsep="0" rowsep="0" headers="t5610h1">only the cocks and valves necessary for the operation of the emergency system are required to be capable of being operated from above the bulkhead deck.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">18.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">Remote controls for cocks and valves referred to in subitem 17(<Emphasis style="italic">b</Emphasis>) shall lead as directly as possible to the remote control location and shall be clearly identified at the upper end and an indication of their operational status given.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">19.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">Where divided deep tanks or side tanks are provided with cross-flooding arrangements to limit the angle of heel after side damage, the arrangements shall be self-acting where practicable.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">20.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">In the case where cross-flooding controls are necessary, such controls shall be clearly identified and shall be operable from above the bulkhead deck.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">21.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">The size of vent pipes for tanks fitted with cross-flooding connections shall be determined by the size of the cross-flooding connections.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5610h0">22.</entry><entry namest="COLSPEC3" nameend="2" colsep="0" rowsep="0" headers="t5610h1">There shall be no closing appliance on vent pipes of tanks fitted with cross-flooding connections.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division VI</Label><TitleText>Group 3 Ships</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.24*" htmlwidth="10%" /><colspec colname="2" colwidth="89.76*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5611h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5611h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5611h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5611h1">The main bilge pipe shall be connected to at least two power pumps.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5611h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5611h1">Two power pumps operating together may be used in lieu of one power pump if the pumps have at least a combined capacity equivalent to the one power pump.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5611h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5611h1">For ships not exceeding 91.5 m in length, one of the power pumps required by item 1 may be driven directly by the main propulsion engine.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5611h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5611h1">For ships not exceeding 150 tons gross tonnage certificated to operate on Minor Waters, Inland Waters Class II or Home Trade Class IV voyages, a manual pump may be used in lieu of a power pump if it has inlet and outlet sizes equal to or greater than those of the power pump.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5611h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5611h1">One power pump with a pumping capacity of not less than 70 per cent of the capacity set out in the Table of Capacities to this Part may be used where the deficiency in pumping capacity is made up by the excess capacity in the other power pumps.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5611h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5611h1">The power pump capacity in m<Sup>3</Sup> per hour for a given internal diameter in millimeters of main bilge pipes is set out in the Table of Capacities to this Part.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5611h0 t5611h1"><Emphasis style="italic">Oil Tankers and Similar Ships</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5611h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5611h1">For oil tankers and similar ships where the main machinery space bilge pumps are not connected to bilge pumping systems outside the machinery space, a main bilge suction pipe that has a cross-sectional area of not less than twice that of the branch bilge suction pipe may be used.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5611h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5611h1">Design of bilge-water pumping systems outside the main machinery space and of ballast water systems in oil tankers and similar ships referred to in item 7 shall be in accordance with rules or codes.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division VII</Label><TitleText>Group 4 Ships</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC4" colwidth="7.55*" htmlwidth="7%" /><colspec colname="2" colwidth="92.50*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5612h0">Item</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5612h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5612h0 t5612h1"><Emphasis style="italic">Piping Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">1.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">An effective pumping system shall be fitted with bilge suction pipes leading to drainage levels that permit all water within any compartment or any watertight section of any compartment to be pumped out through at least one suction pipe when the ship is on an even keel and is either upright or is listing by not more than 5°.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">2.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">In ships certificated to carry more than 12 passengers, bilge water drainage in machinery spaces and watertight compartments shall be such that the spaces and compartments, where practicable, can be pumped out after a casualty when the ship is upright or listing.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">3.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">The arrangement of the pumping system shall be such as to prevent the possibility of water passing from the sea to any compartment or from one watertight compartment to another and for that purpose bilge suction valves shall be of the screw-down non-return type.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">4.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">Machinery space bilge suction pipes shall lead from easily accessible mud boxes fitted with straight tailpipes to the bilge, except that mud boxes are not required to be fitted if the tailpipes lead to easily accessible strainers that have open areas of at least three times the area of the suction pipes.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">5.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">The open ends of bilge suction pipes in compartments outside machinery spaces shall be enclosed in strainers that</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0"></entry><entry colsep="0" rowsep="0" headers="t5612h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5612h1">have perforations of not more than 10 mm in diameter;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0"></entry><entry colsep="0" rowsep="0" headers="t5612h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5612h1">have a total perforated area of not less than twice that of the suction pipe; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0"></entry><entry colsep="0" rowsep="0" headers="t5612h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5612h1">can be cleared without breaking any joint of the suction pipe.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">6.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">Bilge suction pipes shall have an internal diameter of not less than 35 mm, except that ships not in excess of 11 m in length may have suction pipes with an internal diameter of not less than 25 mm.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">7.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">Subject to item 2, where a ship is not in excess of 11 m in length, one machinery space bilge suction pipe only is required to be fitted.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">8.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">Bilge suction pipes for pumping cargo or machinery spaces shall be entirely separate from sea inlet pipes that may be used for filling or emptying spaces where liquid is carried.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">9.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">Sea suction, overboard discharge and bilge valves shall be in easily accessible locations and readily visible.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">10.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">Pipes shall be made in readily removable lengths with flanged joints, or other connections of a type offering security equivalent to that of flanged joints.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5612h0 t5612h1"><Emphasis style="italic">Pumps</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">11.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">The bilge suction pipe shall be connected to at least two pumps of the self-priming type unless a central priming system is provided for the pumps.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">12.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">At least one bilge pump shall be an independent power pump and the other bilge pump may be a main propulsion engine-driven pump or manual pump, if the pumping capacity of each power pump meets the requirements of the Table of Capacities to this Part and the manual pump has inlet and outlet sizes equal to or greater than those of the independent power bilge pump.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">13.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">For ships certificated to operate on Minor Waters, Inland Waters Class II and Home Trade Class IV voyages, each power pump capacity may be reduced by 20 per cent of the capacity set out in the Table of Capacities to this Part, but there shall be no reduction in the piping diameter.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">14.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">For ships in excess of 11 m in length, the independent power pump shall have, in addition to the main bilge suction pipe connection, a direct machinery space bilge suction pipe of equal diameter.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">15.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">Bilge pumps may be used as fire pumps if the simultaneous operation of bilge-pumping systems and fire-pumping systems is not compromised.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">16.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">A general service power pump that is not connected to oil systems may be used as an independent bilge pump if it is fitted with the necessary connections for bilge pumping.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5612h0">17.</entry><entry namest="COLSPEC4" nameend="2" colsep="0" rowsep="0" headers="t5612h1">Pumps shall have isolating valves so that any one pump may continue to operate when another pump is dismantled.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division VIII</Label><TitleText>Group 5 Ships</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="4"><colspec colname="1" colwidth="12.74*" htmlwidth="10%" /><colspec colname="COLSPEC6" colwidth="8.73*" htmlwidth="7%" /><colspec colname="COLSPEC5" colwidth="9.10*" htmlwidth="7%" /><colspec colname="2" colwidth="93.29*" htmlwidth="75%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5613h0">Item</entry><entry namest="COLSPEC6" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5613h1">Requirements</entry></row></thead><tbody><row><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5613h0 t5613h1"><Emphasis style="italic">Piping Systems</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0">1.</entry><entry namest="COLSPEC6" nameend="2" colsep="0" rowsep="0" headers="t5613h1">An effective pumping system shall be fitted with bilge suction pipes leading to drainage levels so that all water within any compartment can be pumped out through at least one suction pipe when the ship is on an even keel and is either upright or is listing by not more than 5°.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0">2.</entry><entry namest="COLSPEC6" nameend="2" colsep="0" rowsep="0" headers="t5613h1">The arrangement of the pumping system shall be such as to prevent the possibility of water passing from the sea to any compartment or from one watertight compartment to another.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0">3.</entry><entry namest="COLSPEC6" nameend="2" colsep="0" rowsep="0" headers="t5613h1">Bilge suction pipes with effective strainers shall have an internal diameter of not less than 25 mm.</entry></row><row topmarginspacing="6"><entry namest="1" nameend="2" colsep="0" rowsep="0" headers="t5613h0 t5613h1"><Emphasis style="italic">Pumps</Emphasis></entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0">4.</entry><entry namest="COLSPEC6" nameend="2" colsep="0" rowsep="0" headers="t5613h1">The bilge pumping system shall have at least two effective bilge pumps.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0">5.</entry><entry namest="COLSPEC6" nameend="2" colsep="0" rowsep="0" headers="t5613h1">Subject to items 6 to 8, at least one bilge pump shall be a power pump and the other bilge pump may be a manual pump if the pumping capacity of the power pump meets the requirements of the Table of Capacities to this Part and the manual pump has inlet and outlet sizes equal to or greater than those of the power pump.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0">6.</entry><entry namest="COLSPEC6" nameend="2" colsep="0" rowsep="0" headers="t5613h1">For a passenger launch in excess of 18 m in length, both pumps shall be power pumps, one of which may be main propulsion engine-driven.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0">7.</entry><entry namest="COLSPEC6" nameend="2" colsep="0" rowsep="0" headers="t5613h1">For a ship or launch not in excess of 11 m in length certificated to operate on Home Trade Class IV or Minor Waters Class II voyages,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0"></entry><entry colsep="0" rowsep="0" headers="t5613h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC5" nameend="2" colsep="0" rowsep="0" headers="t5613h1">the power pump capacity may be reduced by 20 per cent of the capacity set out in the Table of Capacities to this Part but there shall be no reduction in the piping diameter; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0"></entry><entry colsep="0" rowsep="0" headers="t5613h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC5" nameend="2" colsep="0" rowsep="0" headers="t5613h1">an effective bailer may be accepted in lieu of a manual pump.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0">8.</entry><entry namest="COLSPEC6" nameend="2" colsep="0" rowsep="0" headers="t5613h1">The main propulsion engine cooling-water system may be adapted for bilge pumping and used in lieu of the manual pump referred to in item 5 if</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0"></entry><entry colsep="0" rowsep="0" headers="t5613h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry namest="COLSPEC5" nameend="2" colsep="0" rowsep="0" headers="t5613h1">suction strainers are fitted;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0"></entry><entry colsep="0" rowsep="0" headers="t5613h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry namest="COLSPEC5" nameend="2" colsep="0" rowsep="0" headers="t5613h1">the suction valve arrangement is such that seawater cannot pass in the bilges; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0"></entry><entry colsep="0" rowsep="0" headers="t5613h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry namest="COLSPEC5" nameend="2" colsep="0" rowsep="0" headers="t5613h1">there is assurance of continuous water flow by</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0"></entry><entry colsep="0" rowsep="0" headers="t5613h1"></entry><entry colsep="0" rowsep="0" headers="t5613h1">(i)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5613h1">a visible overboard discharge, or</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0"></entry><entry colsep="0" rowsep="0" headers="t5613h1"></entry><entry colsep="0" rowsep="0" headers="t5613h1">(ii)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5613h1">a water-flow indicator.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0">9.</entry><entry namest="COLSPEC6" nameend="2" colsep="0" rowsep="0" headers="t5613h1">Bilge pumps may be used as fire pumps if the simultaneous operation of bilge-pumping systems and fire-pumping systems is not compromised.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0">10.</entry><entry namest="COLSPEC6" nameend="2" colsep="0" rowsep="0" headers="t5613h1">A general service power pump that is not connected to oil systems may be used as an independent bilge pump if it is fitted with the necessary connections for bilge pumping.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0">11.</entry><entry namest="COLSPEC6" nameend="2" colsep="0" rowsep="0" headers="t5613h1">Pumps shall have isolating valves so that any one pump may continue to operate when another pump is dismantled.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5613h0">12.</entry><entry namest="COLSPEC6" nameend="2" colsep="0" rowsep="0" headers="t5613h1">For ships for which plans are not required to be submitted, the arrangement and capacity of the bilge pumping system shall be suitable for the type, service and voyages of the ship.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><TitleText>Table of Capacities</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="47.07*" htmlwidth="47%" /><colspec colname="2" colwidth="52.93*" htmlwidth="53%" /><thead><row rowsep="1" topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry namest="1" nameend="2" colsep="0" rowsep="0" align="center" id="t5614h0"><Emphasis style="smallcaps">pumping capacities for a flow rate of</Emphasis> 2 m/s</entry></row><row rowsep="1" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5614h1" headers="t5614h0">Internal diameter of bilge pipe in mm</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5614h2" headers="t5614h0">Capacity of each power pump in m<Sup>3</Sup> per hour</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">25</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">3.5 (58 L/min)</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">32</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">5.8 (96 L/min)</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">38</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">8.2 (136 L/min)</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">51</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">14.7 (245 L/min)</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">57</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">18.4</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">64</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">23.2</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">70</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">27.7</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">76</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">32.7</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">83</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">39.0</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">90</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">45.8</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">95</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">51.0</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">102</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">58.8</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">108</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">66.0</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">114</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">73.5</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">121</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">82.8</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">127</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">91.2</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">133</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">100.0</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">140</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">110.8</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">146</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">120.5</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">152</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">130.6</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">159</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">143.0</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">165</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">154.0</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">171</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">165.3</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">178</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">179.2</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">184</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">191.4</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">191</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">206.3</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">197</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">219.5</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">203</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">233.0</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h1">210</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5614h0 t5614h2">249.4</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART II</Label><OriginatingRef>(Section 6)</OriginatingRef><TitleText>PLANS</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC7" colwidth="7.55*" htmlwidth="7%" /><colspec colname="2" colwidth="92.50*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5615h0">Item</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5615h1">Information Required</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5615h0">1.</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="0" headers="t5615h1">General arrangement and location of bilge, ballast, heeling, trimming and passive roll stabilizing systems, including venting, overflow and sounding arrangements, showing all connected piping, valves, pumps and equipment, emergency systems and cross-connections to other fluid systems.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5615h0">2.</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="0" headers="t5615h1">Installation details stating assigned working pressures and flow rates of fluid and, where applicable, the Criterion of Service Numeral of the ship, as determined pursuant to the <XRefExternal reference-type="regulation" link="C.R.C.,_c._1431">Hull Construction Regulations</XRefExternal>.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5615h0">3.</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="0" headers="t5615h1">Materials, sizes, capacities, design working pressures, testing arrangements and procedures of pumps, valves, piping, any tank sounding and venting devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5615h0">4.</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="0" headers="t5615h1">Details of</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5615h0"></entry><entry colsep="0" rowsep="0" headers="t5615h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5615h1">pipe connections to flanges or other joining arrangements;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5615h0"></entry><entry colsep="0" rowsep="0" headers="t5615h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5615h1">securing arrangements for pumps, piping and other components and allowances for vibration;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5615h0"></entry><entry colsep="0" rowsep="0" headers="t5615h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5615h1">cross connection with other systems;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5615h0"></entry><entry colsep="0" rowsep="0" headers="t5615h1">(<Emphasis style="italic">d</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5615h1">remote control of valves in systems; and</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5615h0"></entry><entry colsep="0" rowsep="0" headers="t5615h1">(<Emphasis style="italic">e</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5615h1">components preventing the discharge overboard of harmful substances.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5615h0">5.</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="0" headers="t5615h1">Information set out in items 2 to 4 is not required to be submitted for ships not in excess of 18 m in length.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5615h0">6.</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="0" headers="t5615h1">Information for valves and similar minor components referred to in item 3 is not required to be submitted where a manufacturer or an approved classification society certifies that the types of valves or similar minor components have been designed and constructed in accordance with rules or codes.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5615h0">7.</entry><entry namest="COLSPEC7" nameend="2" colsep="0" rowsep="0" headers="t5615h1">Information for pumps referred to in item 3 is not required to be submitted where an approved classification society certifies that the pumps have been designed and constructed in accordance with rules or codes except that the driving motor or engine of pumps shall meet the requirements of Part II of the applicable schedule of Schedules I to XV.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART III</Label><OriginatingRef>(Subsection 12(2))</OriginatingRef><TitleText>CONSTRUCTION AND INSTALLATION INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><TitleText>Construction inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5616h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5616h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5616h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5616h1">None.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Installation inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5617h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5617h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5617h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5617h1">Identification from component inspection certificates, before installation is commenced, of pumps, any tank sounding and venting devices, flexible hoses, materials, welding metal, other components and harmful substances discharge prevention equipment to be used.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5617h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5617h1">Verification that welding was carried out by welders certified by a Provincial Government of Canada, or another authority having similar standards where the welding was carried out outside Canada, for the class of work to be done.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5617h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5617h1">Inspection of welds.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5617h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5617h1">Witnessing of hydrostatic pressure tests in accordance with rules or codes, including hydrostatic pressure test of bilge suction pipes through double bottom tanks to the same pressure as the tanks through which they pass.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5617h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5617h1">Inspection of securing arrangements, connection of bilge and ballast pumping systems and heeling, trimming and passive role tank filling and emptying systems to associated systems and verification of correct adjustment and operational condition of safety, control and monitoring devices.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5617h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5617h1">Witnessing of operational tests of the system in accordance with rules or codes.</entry></row></tbody></tgroup></table></TableGroup><Heading level="1"><Label>PART IV</Label><TitleText>PERIODIC GENERAL INSPECTIONS AND PERIODIC SPECIAL INSPECTIONS</TitleText></Heading><Heading level="2"><Label>Division I</Label><OriginatingRef>(Section 19)</OriginatingRef><TitleText>Periodic General Inspection</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="3"><colspec colname="1" colwidth="11.87*" htmlwidth="11%" /><colspec colname="COLSPEC8" colwidth="7.31*" htmlwidth="7%" /><colspec colname="2" colwidth="92.74*" htmlwidth="83%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5618h0">Item</entry><entry namest="COLSPEC8" nameend="2" colsep="0" rowsep="1" valign="bottom" id="t5618h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5618h0">1.</entry><entry namest="COLSPEC8" nameend="2" colsep="0" rowsep="0" headers="t5618h1">Where applicable and, in the opinion of the inspector, practicable,</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5618h0"></entry><entry colsep="0" rowsep="0" headers="t5618h1">(<Emphasis style="italic">a</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5618h1">inspection of securing arrangements and of locations where fluid leakage and excessive vibration may occur;</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5618h0"></entry><entry colsep="0" rowsep="0" headers="t5618h1">(<Emphasis style="italic">b</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5618h1">verification that all components are in correct adjustment and operational condition; and</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5618h0"></entry><entry colsep="0" rowsep="0" headers="t5618h1">(<Emphasis style="italic">c</Emphasis>)</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5618h1">verification that all control, monitoring and alarm systems, including any tank sounding and venting devices, are in correct adjustment and operational condition.</entry></row></tbody></tgroup></table></TableGroup><Heading level="2"><Label>Division II</Label><TitleText>Periodic Special Inspection</TitleText></Heading><Heading level="3"><Label>Subdivision I</Label><OriginatingRef>(Subsection 20(1))</OriginatingRef><TitleText>Parts to be Inspected</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.56*" htmlwidth="11%" /><colspec colname="2" colwidth="89.44*" htmlwidth="89%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5619h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5619h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5619h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5619h1">External and internal parts of pump and driving components including valves, controls and safety devices.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5619h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5619h1">External and internal parts of bilge valves including emergency bilge suction valves, mud boxes and strainers.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5619h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5619h1">Securing arrangements, without dismantling if a general examination shows that the condition of the components is suitable for further service.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5619h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5619h1">No inspection is required for complex mechanisms where written information is provided to the inspector from firms specializing in the reconditioning of these parts indicating that the parts are in good order and adjustment.</entry></row></tbody></tgroup></table></TableGroup><Heading level="3"><Label>Subdivision II</Label><OriginatingRef>(Subsection 20(2))</OriginatingRef><TitleText>Intervals</TitleText></Heading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5620h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5620h1">Requirements</entry></row></thead><tbody><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5620h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5620h1">At intervals not exceeding five years.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;16&quot;"><ScheduleFormHeading><Label>SCHEDULE XVI</Label><OriginatingRef>(Section 4)</OriginatingRef><TitleText>GENERAL DESIGN SPECIFICATIONS</TitleText></ScheduleFormHeading><TableGroup pointsize="10" topmarginspacing="4"><table frame="topbot"><tgroup cols="2"><colspec colname="1" colwidth="10.45*" align="left" htmlwidth="10%" /><colspec colname="2" colwidth="89.55*" htmlwidth="90%" /><thead><row topdouble="yes" topmarginspacing="6" bottommarginspacing="4"><entry colname="1" colsep="0" rowsep="1" valign="bottom" id="t5621h0">Item</entry><entry colname="2" colsep="0" rowsep="1" valign="bottom" id="t5621h1">Requirements</entry></row></thead><tbody><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">1.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">For ships operating in extremely cold conditions, the design of all essential liquid or steam systems prone to frost damage or operational impairment shall take into account those operational conditions and the low-temperature characteristics of CO<Sub>2</Sub> and any other gases to be used in a ship system.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">2.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">Water piping systems intended for use in areas exposed to freezing conditions shall, as far as practicable, be separate from water systems intended for use in internal spaces of ships, with drainage facilities being fitted in suitable and easily accessible locations.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">3.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">Materials subjected to stress at high or low temperatures shall be resistant to failure due to such temperatures.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">4.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">Means shall be provided to bring into operation propulsion and ship service machinery from a dead ship condition without external aid.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">5.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">Machinery shall be protected against overspeeding and excessive vibration.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">6.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">Ship propulsion systems shall have sufficient power, and arrangements shall be provided to enable the ship to be manoeuvered both ahead and astern and controlled at sea, having regard to the voyages the ship is to make.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">7.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">Normal operation of the propulsion machinery shall be sustainable or restorable where one of the essential auxiliaries becomes inoperative, but a partial reduction in propulsion capability from normal operation is acceptable.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">8.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">For single essential propulsion components, means shall be provided to assure reliability, especially in the case of unconventional arrangements.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">9.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">All machinery shall be designed to operate when the ship is upright and when listing at any angle up to and including 15° either way under static conditions and 22.5° either way under rolling conditions and simultaneously inclined 7.5° by the bow or stern under pitching conditions.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">10.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">Effective guards shall be provided for protection against machinery that moves, is hot or is otherwise hazardous.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">11.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">Slip-resisting gratings, handrails and ladders shall be fitted to allow access to machinery for operational and maintenance purposes with particular attention being given to spaces where fluids may leak, such as steering gear compartments.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">12.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">Sufficient means shall be provided, including lighting, to inspect, maintain and clean machinery parts.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">13.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">Machinery spaces of category A shall be adequately ventilated so that when boilers or other machinery are operating at full power in all weather conditions, an adequate supply of air to the spaces is maintained for the safety and comfort of personnel and the operation of the machinery.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">14.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">Other machinery spaces shall be adequately ventilated.</entry></row><row><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">15.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">Where applicable, at least two independent means of communication shall be provided for communicating orders from the bridge to the location in the machinery space, or in the control room, from which the engines are normally controlled, and one of the means of communication shall be an engine-room telegraph that provides visual indication of the orders and responses both in the machinery space and on the bridge.</entry></row><row bottommarginspacing="2"><entry colname="1" colsep="0" rowsep="0" valign="top" headers="t5621h0">16.</entry><entry colname="2" colsep="0" rowsep="0" valign="top" headers="t5621h1">Appropriate means of communication shall be provided to any locations other than those referred to in item 15 from which the engines may be controlled.</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;17&quot;"><ScheduleFormHeading><Label>SCHEDULE XVII</Label><OriginatingRef>(Sections 9 and 10)</OriginatingRef></ScheduleFormHeading><ImageGroup bilingual="yes" position="center" width="36pc"><AlternateText>Material Test Certificate form</AlternateText><Image source="SOR-90-264img\SOR-90-264_ef005.png" /></ImageGroup></Schedule><Schedule spanlanguages="no" bilingual="no" Code="sc=&quot;&quot;,nb=&quot;18&quot;"><ScheduleFormHeading><Label>SCHEDULE XVIII</Label><OriginatingRef>(Sections 16 and 24)</OriginatingRef></ScheduleFormHeading><ImageGroup bilingual="yes" position="center" width="36pc"><AlternateText>Component Inspection Certificate form</AlternateText><Image source="SOR-90-264img\SOR-90-264_ef006.png" /></ImageGroup></Schedule></Regulation>