Hazardous Products (Pacifiers) Regulations (C.R.C., c. 930)
Full Document:
Regulations are current to 2013-05-26 and last amended on 2011-06-20. Previous Versions
SCHEDULE II
(s. 6)
TESTING PROCEDURE
1. Hold the nipple of the pacifier in a fixed position. Apply a load 10 ± 0.25 pounds in the plane of the axis of the nipple to the handle of the pacifier at a rate of 1 ± 0.25 pounds per second and maintain the final load for 10 ± 0.5 seconds.
2. Hold the guard or shield of the pacifier in a fixed position. Apply a load of 10 ± 0.25 pounds in the plane normal to the axis of the nipple to the handle of the pacifier at a rate of 1 ± 0.25 pounds per second and maintain the final load for 10 ± 0.5 seconds.
3. Repeat the procedure described in section 2 with the load applied to the nipple of the pacifier.
4. Immerse the pacifier in boiling water for 10 ± 0.5 minutes. Remove the pacifier from the boiling water and allow to cool in air at 70 ± 5 degrees Fahrenheit for 15 ± 0.5 minutes. Repeat the tests described in sections 1, 2 and 3.
5. Repeat the entire procedure described in section 4 nine times.