Energy Efficiency Regulations, 2016 (SOR/2016-311)

Regulations are current to 2017-11-20 and last amended on 2017-06-28. Previous Versions

Marginal note:Information

 For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a split-system central air conditioner described in column 1.

TABLE

Column 1Column 2Column 3
ItemEnergy-using ProductStandardInformation
1Split-system central air conditioners manufactured on or after February 3, 1995 and before January 1, 2017CSA C656-05
  • (a) product classification set out in Column II of Table 1 of CSA C656-05;

  • (b) phase of electric current;

  • (c) cooling capacity, in kW (Btu/h);

  • (d) information that indicates whether the product is small-duct and high-velocity;

  • (e) the system the product has, namely, mini-split, multi-split or ducted; and

  • (f) seasonal energy efficiency ratio.

2Split-system central air conditioners manufactured on or after January 1, 2017CSA C656-14
  • (a) product classification set out in Column II of Table 1 of CSA C656-14;

  • (b) phase of electric current;

  • (c) cooling capacity, in kW (Btu/h);

  • (d) information that indicates whether the product is small-duct and high-velocity;

  • (e) the system the product has, namely, mini-split, multi-split or ducted; and

  • (f) seasonal energy efficiency ratio.

SUBDIVISION GLarge Condensing Units

Marginal note:Definition of large condensing unit

 In this Subdivision, large condensing unit means a commercial or industrial condensing unit that is intended for air conditioning applications and that has a cooling capacity of at least 19 kW (65,000 Btu/h) but not more than 70 kW (240,000 Btu/h).

Marginal note:Energy-using product
  •  (1) A large condensing unit is prescribed as an energy-using product.

  • Marginal note:Limit

    (2) However, for the purposes of sections 4, 5 and 138, a large condensing unit is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.

Marginal note:Energy efficiency standards
  •  (1) The energy efficiency standards set out in column 2 of the table to this section apply to large condensing units described in column 1.

  • Marginal note:Testing standard

    (2) A large condensing unit complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C746-98 that are applicable to a large condensing unit as defined in section 136.

    TABLE

    Column 1Column 2
    ItemEnergy-using ProductEnergy Efficiency Standard
    1Large condensing units that are cooled by airEnergy efficiency ratio ≥ 10.1
    2Large condensing units that are cooled by water or evaporationEnergy efficiency ratio ≥ 13.1
Marginal note:Information

 For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C746-98 and provided to the Minister in respect of a large condensing unit:

  • (a) its classification as set out in Column II of Table 1 of CSA C746-98;

  • (b) its cooling capacity, expressed in kilowatts (British thermal units per hour); and

  • (c) its energy efficiency ratio.

SUBDIVISION HChillers

Marginal note:Definitions

 The following definitions apply in this Subdivision.

chiller

chiller means a machine, with or without an integral refrigerant condenser, that is designed to use a refrigerant cycle to remove heat from a liquid and to reject the heat to a cooling medium. (refroidisseur)

CSA C743-02

CSA C743-02 means the CSA standard CAN/CSA-C743-02 entitled Performance Standard for Rating Packaged Water Chillers. (CSA C743-02)

CSA C743-09

CSA C743-09 means the CSA standard CAN/CSA-C743-09 entitled Performance Standard for Rating Packaged Water Chillers. (CSA C743-09)

Marginal note:Energy-using product
  •  (1) A chiller is prescribed as an energy-using product.

  • Marginal note:Limit

    (2) However, for the purposes of sections 4, 5 and 142, a chiller is not considered to be an energy-using product unless it is manufactured on or after October 28, 2004.

Marginal note:Energy efficiency standards
  •  (1) The energy efficiency standards set out in column 2 of the table to this section apply to chillers that are manufactured during the periods set out in column 3.

  • Marginal note:Testing standard

    (2) A chiller complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a chiller as defined in section 140.

    TABLE

    Column 1Column 2Column 3
    ItemStandardEnergy Efficiency StandardPeriod of Manufacture
    1CSA C743-02CSA C743-02, Tables 9 to 15On or after October 28, 2004 and before January 1, 2017
    2CSA C743-09Product’s coefficient of performance and integrated part-load value must meet those applicable to the product in CSA C743-09, Path A or Path B, Table 10On or after January 1, 2017
Marginal note:Information

 For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a chiller described in column 1.

TABLE

Column 1Column 2Column 3
ItemEnergy-using ProductStandardInformation
1Chillers manufactured on or after October 28, 2004 and before January 1, 2017CSA C743-02
  • (a) type;

  • (b) net cooling/heating capacity, in kW (tons);

  • (c) coefficient of performance; and

  • (d) integrated part-load value or non-standard part-load value and a list of non-standard conditions.

2Chillers manufactured on or after January 1, 2017CSA C743-09
  • (a) type;

  • (b) net cooling/heating capacity, in kW (tons);

  • (c) coefficient of performance;

  • (d) compliance Path for the energy-efficiency standard, namely, Path A or Path B of Table 10 to CSA C743-09; and

  • (e) integrated part-load value or non-standard part-load value and a list of non-standard conditions.

 