Commercial Refrigerator-Freezers

Marginal note:Energy-using product
  •  (1) A commercial refrigerator-freezer is prescribed as an energy-using product.

  • Marginal note:Limits

    (2) However, a commercial refrigerator-freezer is not considered to be an energy-using product

    • (a) for the purposes of sections 4 and 5, unless

      • (i) it is closed and is manufactured on or after April 1, 2007, or

      • (ii) it is open and is manufactured on or after January 1, 2012; and

    • (b) for the purpose of section 641, unless

      • (i) it is closed and not transparent and is manufactured on or after April 1, 2007, or

      • (ii) it is open or transparent and is manufactured on or after January 1, 2012.

Marginal note:Energy efficiency standards
  •  (1) The energy efficiency standards set out in column 2 of the table to this section apply to commercial refrigerator-freezers described in column 1 that are manufactured during the periods set out in column 3.

  • Marginal note:Testing standard

    (2) A commercial refrigerator-freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C657, Test Procedure A, that are applicable to a commercial refrigerator-freezer as defined in section 636.

    TABLE

    Column 1Column 2Column 3
    ItemEnergy-using ProductEnergy Efficiency StandardPeriod of Manufacture
    1Commercial refrigerator-freezers that are closed and not transparentEdaily ≤ 0.00964 AV + 2.63On or after April 1, 2007 and before January 1, 2008
    2Commercial refrigerator-freezers that are closed and not transparentEdaily ≤ 0.00964 AV + 1.65On or after January 1, 2008 and before January 1, 2010
    3Commercial refrigerator-freezers that are closed and not transparentEdaily ≤ the greater of (0.00953 AV – 0.71) and 0.70On or after January 1, 2010
    4Commercial refrigerator-freezers that are open or transparentCSA C657, Table 5On or after January 1, 2012
Marginal note:Information

 For the purpose of subsection 5(1) of the Act, the information set out in column 2 of the table to this section must be collected in accordance with CSA C657, Test Procedure A, and provided to the Minister in respect of a commercial refrigerator-freezer described in column 1.

TABLE

Column 1Column 2
ItemEnergy-using ProductInformation
1Commercial refrigerator-freezers that are closed, not transparent and manufactured on or after April 1, 2007
  • (a) Edaily;

  • (b) AV; and

  • (c) for each compartment tested at the lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting.

2Commercial refrigerator-freezers that are transparent and manufactured on or after April 1, 2007 and before January 1, 2012
  • (a) Edaily;

  • (b) AV; and

  • (c) for each compartment tested at the lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting.

3Commercial refrigerator-freezers that are open or transparent, and manufactured on or after January 1, 2012
  • (a) Edaily;

  • (b) for each of compartment tested at the lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting; and

  • (c) for each compartment, its equipment class designation and TDA.

Commercial Freezers

Marginal note:Energy-using product
  •  (1) A commercial freezer is prescribed as an energy-using product.

  • Marginal note:Limits

    (2) However, a commercial freezer is not considered to be an energy-using product

    • (a) for the purposes of sections 4 and 5, unless it is manufactured on or after April 1, 2007; and

    • (b) for the purpose of section 644, unless

      • (i) it is closed and was manufactured on or after April 1, 2007 and before January 1, 2012, or

      • (ii) it is manufactured on or after January 1, 2012.

Marginal note:Energy efficiency standards
  •  (1) The energy efficiency standards set out in column 2 of the table to this section apply to commercial freezers described in column 1 that are manufactured during the periods set out in column 3.

  • Marginal note:Testing standard

    (2) A commercial freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C657, Test Procedure A, that are applicable to a commercial freezer as defined in section 636.

    TABLE

    Column 1Column 2Column 3
    ItemEnergy-using ProductEnergy Efficiency StandardPeriod of Manufacture
    1Commercial freezers that are closed, not transparent and have a volume of < 340 LEdaily ≤ 7.62On or after April 1, 2007 and before January 1, 2008
    2Commercial freezers that are closed, not transparent and have a volume of < 340 LEdaily ≤ 7.07On or after January 1, 2008 and before January 1, 2010
    3Commercial freezers that are closed, not transparent and have a volume of ≥ 340 LEdaily ≤ 0.0141 V + 2.83On or after April 1, 2007 and before January 1, 2008
    4Commercial freezers that are closed, not transparent and have a volume of ≥ 340 LEdaily ≤ 0.0141 V + 2.28On or after January 1, 2008 and before January 1, 2010
    5Commercial freezers that are closed and not transparentEdaily ≤ 0.01413 V + 1.38On or after January 1, 2010
    6Commercial freezers that are transparentEdaily ≤ 0.0332 V + 5.10On or after April 1, 2007 and before January 1, 2010
    7Commercial freezers that are transparentEdaily ≤ 0.02649 V + 4.10On or after January 1, 2010
    8Commercial freezers that are openCSA C657, Table 5On or after January 1, 2012
 