Basic Search

 
Display / Hide Categories
Results 1-5 of 708
Didn't find what you're looking for?
Search all Government of Canada websites

  1. Transportation of Dangerous Goods Regulations - SOR/2001-286 (SCHEDULE 1 : Classes 1 to 9)

    [...]

    LEGEND

    Column 1 Column 2 Column 3 Column 4 Column 5 Column 6 Column 7 Column 8 Column 9
    UN Number Shipping Name and Description Class Packing Group/ Category Special Provisions

    [...]

    Explosive Limit and Limited Quantity Index

    [...]

    Excepted Quantities
    ERAP Index Passenger Carrying Vessel Index Passenger Carrying Road Vehicle or Passenger Carrying Railway Vehicle Index
    UN3111 ORGANIC PEROXIDE TYPE B, LIQUID, TEMPERATURE CONTROLLED

    [...]

    II 16, 28, 38 0 E0 75 Forbidden Forbidden
    UN3112 ORGANIC PEROXIDE TYPE B, SOLID, TEMPERATURE CONTROLLED

    [...]

    II 16, 28, 38 0 E0 75 Forbidden Forbidden
    UN3113 ORGANIC PEROXIDE TYPE C, LIQUID, TEMPERATURE CONTROLLED 5.2 II 16, 28, 38 0 E0 75 Forbidden Forbidden
    UN3114 ORGANIC PEROXIDE TYPE C, SOLID, TEMPERATURE CONTROLLED 5.2 II 16, 28, 38 0 E0 75 Forbidden Forbidden
    UN3115 ORGANIC PEROXIDE TYPE D, LIQUID, TEMPERATURE CONTROLLED 5.2 II 16, 28, 38 0 E0 Forbidden Forbidden
    UN3116 ORGANIC PEROXIDE TYPE D, SOLID, TEMPERATURE CONTROLLED 5.2 II 16, 28, 38 0 E0 Forbidden Forbidden
    UN3117 ORGANIC PEROXIDE TYPE E, LIQUID, TEMPERATURE CONTROLLED 5.2 II 16, 28, 38 0 E0 Forbidden Forbidden
    UN3118 ORGANIC PEROXIDE TYPE E, SOLID, TEMPERATURE CONTROLLED 5.2 II 16, 28, 38 0 E0 Forbidden Forbidden
    UN3119 ORGANIC PEROXIDE TYPE F, LIQUID, TEMPERATURE CONTROLLED 5.2 II 16 0 E0 Forbidden Forbidden
    UN3120 ORGANIC PEROXIDE TYPE F, SOLID, TEMPERATURE CONTROLLED 5.2 II 16 0 E0 Forbidden Forbidden
    UN3231 SELF-REACTIVE LIQUID TYPE B, TEMPERATURE CONTROLLED

    [...]

    II 16, 28, 38 0 E0 75 Forbidden Forbidden
    UN3232 SELF-REACTIVE SOLID TYPE B, TEMPERATURE CONTROLLED

    [...]

    II 16, 28, 38 0 E0 75 Forbidden Forbidden
    UN3233 SELF-REACTIVE LIQUID TYPE C, TEMPERATURE CONTROLLED 4.1 II 16, 28, 38 0 E0 75 Forbidden Forbidden
    UN3234 SELF-REACTIVE SOLID TYPE C, TEMPERATURE CONTROLLED 4.1 II 16, 28, 38 0 E0 75 Forbidden Forbidden
    UN3235 SELF-REACTIVE LIQUID TYPE D, TEMPERATURE CONTROLLED 4.1 II 16, 28, 38 0 E0 75 Forbidden Forbidden
    UN3236 SELF-REACTIVE SOLID TYPE D, TEMPERATURE CONTROLLED 4.1 II 16, 28, 38 0 E0 Forbidden Forbidden
    UN3237 SELF-REACTIVE LIQUID TYPE E, TEMPERATURE CONTROLLED 4.1 II 16, 28, 38 0 E0 Forbidden Forbidden
    UN3238 SELF-REACTIVE SOLID TYPE E, TEMPERATURE CONTROLLED 4.1 II 16, 28, 38 0 E0 Forbidden Forbidden
    UN3239 SELF-REACTIVE LIQUID TYPE F, TEMPERATURE CONTROLLED 4.1 II 16, 28, 38 0 E0 Forbidden Forbidden
    UN3240 SELF-REACTIVE SOLID TYPE F, TEMPERATURE CONTROLLED 4.1 II 16, 28, 38 0 E0 Forbidden Forbidden
    UN3256 ELEVATED TEMPERATURE LIQUID, FLAMMABLE, N.O.S., with flash point above 60°C, at or above its flash point 3 III 16 0 E0 Forbidden
    UN3257 ELEVATED TEMPERATURE LIQUID, N.O.S., at or above 100°C and below its flash point (including molten metals, molten salts, etc.) 9 III 16 0 E0 Forbidden
    UN3258 ELEVATED TEMPERATURE SOLID, N.O.S., at or above 240°C 9 III 16 0 E0 Forbidden
    UN3533 POLYMERIZING SUBSTANCE, SOLID, TEMPERATURE CONTROLLED, N.O.S. 4.1 III 16, 155 0 E0 Forbidden
    UN3534 POLYMERIZING SUBSTANCE, LIQUID, TEMPERATURE CONTROLLED, N.O.S. 4.1 III 16, 155 0 E0 Forbidden

    [...]


  2. Transportation of Dangerous Goods Regulations - SOR/2001-286 (SCHEDULE 3 : Alphabetical Index)

    [...]

    LEGEND

    Column 1A Column 1B Column 2 Column 3 Column 4
    Shipping and/or Technical Name Appellation réglementaire et/ou technique Primary Class UN Number Marine Pollutant
    ELEVATED TEMPERATURE LIQUID, N.O.S., at or above 100°C and below its flash point including molten metals, molten salts, etc. LIQUIDE TRANSPORTÉ À CHAUD, N.S.A. (y compris métal fondu, sel fondu, etc.), à une température égale ou supérieure à 100 °C et inférieure à son point 9 UN3257
    ELEVATED TEMPERATURE LIQUID, FLAMMABLE, N.O.S., with flash point above 60°C, at or above its flash point LIQUIDE TRANSPORTÉ À CHAUD, INFLAMMABLE, N.S.A., ayant un point d’éclair supérieur à 60 °C, à une température égale ou supérieure à son point d’éclair 3 UN3256
    ELEVATED TEMPERATURE SOLID, N.O.S., at or above 240°C SOLIDE TRANSPORTÉ À CHAUD, N.S.A., à une température égale ou supérieure à 240 °C 9 UN3258
    ORGANIC PEROXIDE TYPE B, LIQUID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE B, LIQUIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3111
    ORGANIC PEROXIDE TYPE B, SOLID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE B, SOLIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3112
    ORGANIC PEROXIDE TYPE C, LIQUID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE C, LIQUIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3113
    ORGANIC PEROXIDE TYPE C, SOLID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE C, SOLIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3114
    ORGANIC PEROXIDE TYPE D, LIQUID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE D, LIQUIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3115
    ORGANIC PEROXIDE TYPE D, SOLID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE D, SOLIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3116
    ORGANIC PEROXIDE TYPE E, LIQUID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE E, LIQUIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3117
    ORGANIC PEROXIDE TYPE E, SOLID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE E, SOLIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3118
    ORGANIC PEROXIDE TYPE F, LIQUID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE F, LIQUIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3119
    ORGANIC PEROXIDE TYPE F, SOLID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE F, SOLIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3120
    POLYMERIZING SUBSTANCE, LIQUID, TEMPERATURE CONTROLLED, N.O.S. MATIÈRE LIQUIDE QUI POLYMÉRISE, AVEC RÉGULATEUR DE TEMPÉRATURE, N.S.A. 4.1 UN3534
    POLYMERIZING SUBSTANCE, SOLID, TEMPERATURE CONTROLLED, N.O.S. MATIÈRE SOLIDE QUI POLYMÉRISE, AVEC RÉGULATEUR DE TEMPÉRATURE, N.S.A. 4.1 UN3533
    SELF-REACTIVE LIQUID TYPE B, TEMPERATURE CONTROLLED LIQUIDE AUTORÉACTIF DU TYPE B, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3231
    SELF-REACTIVE LIQUID TYPE C, TEMPERATURE CONTROLLED LIQUIDE AUTORÉACTIF DU TYPE C, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3233
    SELF-REACTIVE LIQUID TYPE D, TEMPERATURE CONTROLLED LIQUIDE AUTORÉACTIF DU TYPE D, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3235
    SELF-REACTIVE LIQUID TYPE E, TEMPERATURE CONTROLLED LIQUIDE AUTORÉACTIF DU TYPE E, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3237
    SELF-REACTIVE LIQUID TYPE F, TEMPERATURE CONTROLLED LIQUIDE AUTORÉACTIF DU TYPE F, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3239
    SELF-REACTIVE SOLID TYPE B, TEMPERATURE CONTROLLED SOLIDE AUTORÉACTIF DU TYPE B, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3232
    SELF-REACTIVE SOLID TYPE C, TEMPERATURE CONTROLLED SOLIDE AUTORÉACTIF DU TYPE C, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3234
    SELF-REACTIVE SOLID TYPE D, TEMPERATURE CONTROLLED SOLIDE AUTORÉACTIF DU TYPE D, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3236
    SELF-REACTIVE SOLID TYPE E, TEMPERATURE CONTROLLED SOLIDE AUTORÉACTIF DU TYPE E, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3238
    SELF-REACTIVE SOLID TYPE F, TEMPERATURE CONTROLLED SOLIDE AUTORÉACTIF DU TYPE F, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3240

    [...]


  3. Transportation of Dangerous Goods Regulations - SOR/2001-286 (SCHEDULE 2 : Special Provisions)

    [...]

    [...]

    24 Lead compounds are considered to be insoluble if they exhibit a solubility of 5% or less when they are mixed in a ratio of 1:1 000 with 0.07 molar hydrochloric acid and stirred for one hour at a temperature of 23°C ± 2°C.

    [...]

    28 A person must not handle, offer for transport or transport these dangerous goods unless they are stabilized and their temperature is maintained below the control temperature while they are being transported.

    [...]

    • [...]

    • (2) These Regulations, except for Part 1 (Coming into Force, Repeal, Interpretation, General Provisions and Special Cases) and Part 2 (Classification), do not apply to UN2800, BATTERIES, WET, NON-SPILLABLE, electric storage, that are not intended for disposal, if

      • (a) at a temperature of 55°C, electrolyte will not flow from a ruptured or cracked battery case and there is no free liquid to flow; and

    [...]

    • 41 (1) A person must not offer for transport, handle or transport UN3356, OXYGEN GENERATOR, CHEMICAL, that contains dangerous goods included in Class 5.1, unless

      • [...]

      • (c) the oxygen generator is transported in a means of containment that is inside another means of containment so that, if the oxygen generator is activated,

        • [...]

        • (iii) the outside surface temperature of the outer means of containment will not exceed 100°C.

    [...]

    45 Maneb and maneb preparations that have been stabilized against self-heating do not have to be classified with a primary class of Class 4.2 or be assigned the UN number UN2210 if it can be demonstrated by testing that l m3 of the substance does not self-ignite and that the temperature at the centre of a l m3 sample does not exceed 200°C when the sample is kept in a storage area maintained at a temperature of not less than 75°C ± 2°C for a period of 24 hours. In this case, the dangerous goods have the classification assigned to the UN number UN2968.

    [...]

    55 Aqueous solutions of inorganic nitrate substances do not meet the criteria for inclusion in Class 5.1 if the concentration of the inorganic nitrate substances in the aqueous solution at the minimum temperature that may be encountered in transport is not more than 80% of the saturation limit of the inorganic nitrate substance in solution.

    [...]

    • [...]

    • (3) Fuel cell cartridges must be filled in accordance with procedures specified by the manufacturer and the manufacturer must provide, with each fuel cell cartridge, the following information:

      • [...]

      • (e) minimum and maximum temperature range; and

    • [...]

    • (6) Each cartridge design type, including the design types for cartridges integral to a fuel cell, must pass a hydrogen cycling test in which the fuel cell cartridge is cycled, for at least 100 cycles, from not more than 5% rated hydrogen capacity to not less than 95% rated hydrogen capacity and then back to not more than 5% rated hydrogen capacity. The rated charging pressure must be used for charging, and temperatures must be held within the operating temperature range.

    [...]

    131 These dangerous goods must not be transported if the temperature of the dangerous goods at the time of loading exceeds the higher of 35°C or 5°C above the ambient temperature.

    [...]

    • 153 (1) This shipping name applies to polyester resin kits that consist of

      • [...]

      • (b) an activator that is an organic peroxide of type D, E or F that is included in Class 5.2 and does not require temperature control.

    [...]

    • 155 (1) If these dangerous goods are stabilized by temperature control, they must be offered for transport, handled or transported in accordance with section 7.1.5 of the UN Recommendations.

    • (2) If chemical stabilization is employed, the person offering the means of containment for transport must ensure that the level of stabilization will prevent a dangerous polymerization of the dangerous goods at a bulk mean temperature of 50°C in the case of a small means of containment or an intermediate bulk container (IBC) or, in the case of a large means of containment that is not an IBC, at a bulk mean temperature of 45°C.

    • (3) If chemical stabilization may become ineffective at lower temperatures within the anticipated duration of transport, temperature control is required. In determining whether chemical stabilization may become ineffective at lower temperatures, the person offering the means of containment for transport must take at least the following the factors into consideration:

      • [...]

      • (b) the temperature of the dangerous goods when offered for transport;

      • (c) the duration of the transport and the seasonal ambient temperature conditions typically encountered during transport; and

    [...]

    • 158 (1) These Regulations, except for Parts 1 and 2, do not apply in respect of anhydrous ammonia that is adsorbed or absorbed on a solid material that is contained in an ammonia dispensing system or in a pressure receptacle that is intended to form part of an ammonia dispensing system if

      • (a) the adsorption or absorption presents the following properties:

        • (i) the pressure at a temperature of 20°C in the receptacle is less than 60 kPa (0.6 bar),

        • (ii) the pressure at a temperature of 35°C in the receptacle is less than 100 kPa (1 bar), and

        • (iii) the pressure at a temperature of 85°C in the receptacle is less than 1.2 MPa (12 bar);

    • (2) The mechanical strength properties set out in subsection (1) must be tested

      • [...]

      • (b) by increasing the temperature until the pressures specified in subsection (1) are reached.

        [...]

    [...]

    • 161 (1) Before loading, these dangerous goods must be cooled to ambient temperature, unless they have been calcined to remove moisture.

    [...]


  4. Energy Efficiency Regulations, 2016 - SOR/2016-311 (Section 642)

     For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a commercial refrigerator-freezer described in column 1.

    TABLE

    Column 1 Column 2 Column 3
    Item Energy-using Product Testing Standard Information
    1 Commercial refrigerator-freezers that are self-contained, closed, not transparent and manufactured on or after April 1, 2007 and before March 27, 2017 CSA C657, Test Procedure A
    • [...]

    • (c) for each compartment tested at the lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting.

    2 Commercial refrigerator-freezers that are self-contained, transparent and manufactured on or after April 1, 2007 and before January 1, 2012 CSA C657, Test Procedure A
    • [...]

    • (c) for each compartment tested at the lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting.

    3 Commercial refrigerator-freezers that are self-contained, open or transparent and manufactured on or after January 1, 2012 and before March 27, 2017 CSA C657, Test Procedure A
    • [...]

    • (b) for each compartment tested at the lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting; and

    4 Commercial refrigerator-freezers that are remote-condensing and manufactured on or after January 1, 2012 and before March 27, 2017 CSA C657, Test Procedure A
    • [...]

    • (b) for each compartment tested at the lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting; and

    5 Commercial refrigerator-freezers that are manufactured on or after March 27, 2017 CSA C657, Test Procedure B
    • [...]

    • (b) for each compartment tested at the lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting; and

    [...]


  5. Canada Oil and Gas Installations Regulations - SOR/96-118 (Section 23)
    •  (1) In this section,

      class A-60 division

      class A-60 division means a division formed by a bulkhead or deck that is

      • [...]

      • (c) insulated with non-combustible materials so that, if either side is exposed to a standard fire test, after 60 minutes the average temperature on the unexposed face will not increase by more than 139°C above the initial temperature and the temperature at any point on the unexposed face, including any joint, will not increase by more than 180°C above the initial temperature; (cloisonnement de classe A-60)

      class B-15 division

      class B-15 division means a division formed by a bulkhead, ceiling or lining that is

      • [...]

      • (c) insulated so that if either face is exposed to the first 30 minute period of a standard fire test, the average temperature on the unexposed face will not increase at any time during the first 15 minutes of the test by more than 139°C above that initial temperature, and the temperature at any point on the unexposed face, including any joint, will not increase by more than 225°C above the initial temperature after exposure for 15 minutes; (cloisonnement de classe B-15)

      class H-120 division

      class H-120 division means a division formed by a bulkhead or deck that is

      • [...]

      • (c) insulated with non-combustible material so that, if either face is exposed to a hydrocarbon fire test, after 120 minutes the average temperature on the unexposed face will not increase by more than 139°C above the initial temperature, and the temperature at any point on the unexposed face, including any joint, will not increase by more than 180°C above the initial temperature; (cloisonnement de classe H-120)

      hydrocarbon fire test

      hydrocarbon fire test means a test in which a specimen division, which division resembles as closely as possible the intended construction of the division, includes, where appropriate, at least one joint and has an exposed surface of not less than 4.65 m2 and a height or a length of not less than 2.44 m, is exposed in a test furnace to temperatures corresponding approximately to a time-temperature relationship defined by a smooth curve drawn through the following temperature points measured above the initial furnace temperature, namely,

      [...]



Type:

Titles:

Date modified: