  1. Specifications Relating to Non-automatic Weighing Devices (1998) - SI/98-81 (Section 24)
    •  (1) A weighing device shall perform within the applicable limits of error when exposed

      • (a) where a temperature range is marked on the device, within that temperature range; and

      • (b) where no temperature range is marked on the device, at any temperature of at least -10°C and no more than 40°C.

    • (2) The minimum marked temperature range on a weighing device shall be

      [...]


  2. Specifications Relating to Non-automatic Weighing Devices (1998) - SI/98-81 (Section 28)

     A weighing device shall perform within applicable limits of error when exposed to relative humidity of up to 85 per cent

    • (a) where a temperature range is marked on the device, within that temperature range; and

    • (b) where no temperature range is marked on the device, at any temperature of at least -10°C and no more than 40°C.


  3. Specifications Relating to Non-automatic Weighing Devices (1998) - SI/98-81 (Section 23)

     The weight indication at or near zero shall not vary by more than

    • (a) in the case of Class Oval outline with the text I inside weighing devices, one verification scale interval for each change in temperature of 1°C;

    • (b) in the case of Class Oval outline with the text IIIHD inside weighing devices, three verification scale intervals for each change in temperature of 5°C; and

    • (c) in the case of all other classes of weighing device, one verification scale interval for each change in temperature of 5°C.