  1. Canada Oil and Gas Installations Regulations - SOR/96-118 (Section 23)
    •  (1) In this section,

      class A-60 division

      class A-60 division means a division formed by a bulkhead or deck that is

      • [...]

      • (c) insulated with non-combustible materials so that, if either side is exposed to a standard fire test, after 60 minutes the average temperature on the unexposed face will not increase by more than 139°C above the initial temperature and the temperature at any point on the unexposed face, including any joint, will not increase by more than 180°C above the initial temperature; (cloisonnement de classe A-60)

      class B-15 division

      class B-15 division means a division formed by a bulkhead, ceiling or lining that is

      • [...]

      • (c) insulated so that if either face is exposed to the first 30 minute period of a standard fire test, the average temperature on the unexposed face will not increase at any time during the first 15 minutes of the test by more than 139°C above that initial temperature, and the temperature at any point on the unexposed face, including any joint, will not increase by more than 225°C above the initial temperature after exposure for 15 minutes; (cloisonnement de classe B-15)

      class H-120 division

      class H-120 division means a division formed by a bulkhead or deck that is

      • [...]

      • (c) insulated with non-combustible material so that, if either face is exposed to a hydrocarbon fire test, after 120 minutes the average temperature on the unexposed face will not increase by more than 139°C above the initial temperature, and the temperature at any point on the unexposed face, including any joint, will not increase by more than 180°C above the initial temperature; (cloisonnement de classe H-120)

      hydrocarbon fire test

      hydrocarbon fire test means a test in which a specimen division, which division resembles as closely as possible the intended construction of the division, includes, where appropriate, at least one joint and has an exposed surface of not less than 4.65 m2 and a height or a length of not less than 2.44 m, is exposed in a test furnace to temperatures corresponding approximately to a time-temperature relationship defined by a smooth curve drawn through the following temperature points measured above the initial furnace temperature, namely,

      [...]


  2. Nova Scotia Offshore Petroleum Installations Regulations - SOR/95-191 (Section 23)
    •  (1) In this section,

      class A-60 division

      class A-60 division means a division formed by a bulkhead or deck that is

      • [...]

      • (c) insulated with non-combustible materials so that, if either side is exposed to a standard fire test, after 60 minutes the average temperature on the unexposed face will not increase by more than 139°C above the initial temperature and the temperature at any point on the unexposed face, including any joint, will not increase by more than 180°C above the initial temperature; (cloisonnement de classe A-60)

      class B-15 division

      class B-15 division means a division formed by a bulkhead, ceiling or lining that is

      • [...]

      • (c) insulated so that if either face is exposed to the first 30 minute period of a standard fire test, the average temperature on the unexposed face will not increase at any time during the first 15 minutes of the test by more than 139°C above that initial temperature, and the temperature at any point on the unexposed face, including any joint, will not increase by more than 225°C above the initial temperature after exposure for 15 minutes; (cloisonnement de classe B-15)

      class H-120 division

      class H-120 division means a division formed by a bulkhead or deck that is

      • [...]

      • (c) insulated with non-combustible material so that, if either face is exposed to a hydrocarbon fire test, after 120 minutes the average temperature on the unexposed face will not increase by more than 139°C above the initial temperature, and the temperature at any point on the unexposed face, including any joint, will not increase by more than 180°C above the initial temperature; (cloisonnement de classe H-120)

      hydrocarbon fire test

      hydrocarbon fire test means a test in which a specimen division, which division resembles as closely as possible the intended construction of the division, includes, where appropriate, at least one joint and has an exposed surface of not less than 4.65 m2 and a height or a length of not less than 2.44 m, and is exposed in a test furnace to temperatures corresponding approximately to a time-temperature relationship defined by a smooth curve drawn through the following temperature points measured above the initial furnace temperature, namely,

      [...]


  3. Newfoundland Offshore Petroleum Installations Regulations - SOR/95-104 (Section 23)
    •  (1) In this section,

      class A-60 division

      class A-60 division means a division formed by a bulkhead or deck that is

      • [...]

      • (c) insulated with non-combustible materials so that, if either side is exposed to a standard fire test, after 60 minutes the average temperature on the unexposed face will not increase by more than 139 °C above the initial temperature and the temperature at any point on the unexposed face, including any joint, will not increase by more than 180 °C above the initial temperature; (cloisonnement de classe A-60)

      class B-15 division

      class B-15 division means a division formed by a bulkhead, ceiling or lining that is

      • [...]

      • (c) insulated so that if either face is exposed to the first 30 minute period of a standard fire test, the average temperature on the unexposed face will not increase at any time during the first 15 minutes of the test by more than 139 °C above that initial temperature, and the temperature at any point on the unexposed face, including any joint, will not increase by more than 225 °C above the initial temperature after exposure for 15 minutes; (cloisonnement de classe B-15)

      class H-120 division

      class H-120 division means a division formed by a bulkhead or deck that is

      • [...]

      • (c) insulated with non-combustible material so that, if either face is exposed to a hydrocarbon fire test, after 120 minutes the average temperature on the unexposed face will not increase by more than 139 °C above the initial temperature, and the temperature at any point on the unexposed face, including any joint, will not increase by more than 180 °C above the initial temperature; (cloisonnement de classe H-120)

      hydrocarbon fire test

      hydrocarbon fire test means a test in which a specimen division, which division resembles as closely as possible the intended construction of the division, includes, where appropriate, at least one joint and has an exposed surface of not less than 4.65 m2 and a height or a length of not less than 2.44 m, and is exposed in a test furnace to temperatures corresponding approximately to a time-temperature relationship defined by a smooth curve drawn through the following temperature points measured above the initial furnace temperature, namely,

      [...]


  4. Motor Vehicle Safety Regulations - C.R.C., c. 1038 (Section 2)
    •  (1) In these Regulations,

      ambient temperature

      ambient temperature means the surrounding air temperature measured at such a distance from a vehicle under test that the temperature is not significantly affected by heat from the vehicle; (température ambiante)

      engine coolant temperature indicator

      engine coolant temperature indicator  means a device that presents information concerning the temperature of the coolant; (indicateur de température du liquide de refroidissement)

      engine coolant temperature tell-tale

      engine coolant temperature tell-tale  means a signal that, when alight, indicates that the temperature of the engine coolant is above the normal engine running temperature prescribed by the manufacturer; (témoin de température du liquide de refroidissement)

      initial brake temperature

      initial brake temperature[Repealed, SOR/99-357, s. 1]

    [...]


  5. Transportation of Dangerous Goods Regulations - SOR/2001-286 (SCHEDULE 3 : Alphabetical Index)

    [...]

    LEGEND

    Column 1A Column 1B Column 2 Column 3 Column 4
    Shipping and/or Technical Name Appellation réglementaire et/ou technique Primary Class UN Number Marine Pollutant
    ELEVATED TEMPERATURE LIQUID, N.O.S., at or above 100°C and below its flash point including molten metals, molten salts, etc. LIQUIDE TRANSPORTÉ À CHAUD, N.S.A. (y compris métal fondu, sel fondu, etc.), à une température égale ou supérieure à 100 °C et inférieure à son point 9 UN3257
    ELEVATED TEMPERATURE LIQUID, FLAMMABLE, N.O.S., with flash point above 60°C, at or above its flash point LIQUIDE TRANSPORTÉ À CHAUD, INFLAMMABLE, N.S.A., ayant un point d’éclair supérieur à 60 °C, à une température égale ou supérieure à son point d’éclair 3 UN3256
    ELEVATED TEMPERATURE SOLID, N.O.S., at or above 240°C SOLIDE TRANSPORTÉ À CHAUD, N.S.A., à une température égale ou supérieure à 240 °C 9 UN3258
    ORGANIC PEROXIDE TYPE B, LIQUID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE B, LIQUIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3111
    ORGANIC PEROXIDE TYPE B, SOLID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE B, SOLIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3112
    ORGANIC PEROXIDE TYPE C, LIQUID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE C, LIQUIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3113
    ORGANIC PEROXIDE TYPE C, SOLID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE C, SOLIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3114
    ORGANIC PEROXIDE TYPE D, LIQUID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE D, LIQUIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3115
    ORGANIC PEROXIDE TYPE D, SOLID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE D, SOLIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3116
    ORGANIC PEROXIDE TYPE E, LIQUID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE E, LIQUIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3117
    ORGANIC PEROXIDE TYPE E, SOLID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE E, SOLIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3118
    ORGANIC PEROXIDE TYPE F, LIQUID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE F, LIQUIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3119
    ORGANIC PEROXIDE TYPE F, SOLID, TEMPERATURE CONTROLLED PEROXYDE ORGANIQUE DU TYPE F, SOLIDE, AVEC RÉGULATION DE TEMPÉRATURE 5.2 UN3120
    POLYMERIZING SUBSTANCE, LIQUID, TEMPERATURE CONTROLLED, N.O.S. MATIÈRE LIQUIDE QUI POLYMÉRISE, AVEC RÉGULATEUR DE TEMPÉRATURE, N.S.A. 4.1 UN3534
    POLYMERIZING SUBSTANCE, SOLID, TEMPERATURE CONTROLLED, N.O.S. MATIÈRE SOLIDE QUI POLYMÉRISE, AVEC RÉGULATEUR DE TEMPÉRATURE, N.S.A. 4.1 UN3533
    SELF-REACTIVE LIQUID TYPE B, TEMPERATURE CONTROLLED LIQUIDE AUTORÉACTIF DU TYPE B, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3231
    SELF-REACTIVE LIQUID TYPE C, TEMPERATURE CONTROLLED LIQUIDE AUTORÉACTIF DU TYPE C, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3233
    SELF-REACTIVE LIQUID TYPE D, TEMPERATURE CONTROLLED LIQUIDE AUTORÉACTIF DU TYPE D, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3235
    SELF-REACTIVE LIQUID TYPE E, TEMPERATURE CONTROLLED LIQUIDE AUTORÉACTIF DU TYPE E, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3237
    SELF-REACTIVE LIQUID TYPE F, TEMPERATURE CONTROLLED LIQUIDE AUTORÉACTIF DU TYPE F, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3239
    SELF-REACTIVE SOLID TYPE B, TEMPERATURE CONTROLLED SOLIDE AUTORÉACTIF DU TYPE B, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3232
    SELF-REACTIVE SOLID TYPE C, TEMPERATURE CONTROLLED SOLIDE AUTORÉACTIF DU TYPE C, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3234
    SELF-REACTIVE SOLID TYPE D, TEMPERATURE CONTROLLED SOLIDE AUTORÉACTIF DU TYPE D, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3236
    SELF-REACTIVE SOLID TYPE E, TEMPERATURE CONTROLLED SOLIDE AUTORÉACTIF DU TYPE E, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3238
    SELF-REACTIVE SOLID TYPE F, TEMPERATURE CONTROLLED SOLIDE AUTORÉACTIF DU TYPE F, AVEC RÉGULATION DE TEMPÉRATURE 4.1 UN3240

    [...]