﻿<?xml version="1.0" encoding="utf-8"?><Regulation lims:pit-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:current-date="2019-06-21" lims:inforce-start-date="2006-03-22" lims:fid="565906" lims:id="565906" gazette-part="II" regulation-type="SOR" xml:lang="en" xmlns:lims="http://justice.gc.ca/lims"><Identification lims:inforce-start-date="2006-03-22" lims:fid="565907" lims:id="565907"><InstrumentNumber>C.R.C., c. 828</InstrumentNumber><ConsolidationDate lims:inforce-start-date="2006-03-22"><Date><YYYY>2019</YYYY><MM>6</MM><DD>22</DD></Date></ConsolidationDate><EnablingAuthority lims:inforce-start-date="2006-03-22" lims:fid="565909" lims:id="565909"><XRefExternal reference-type="act" link="F-14">FISHERIES ACT</XRefExternal></EnablingAuthority><ShortTitle lims:inforce-start-date="2006-03-22" lims:fid="565910" lims:id="565910">Petroleum Refinery Liquid Effluent Regulations</ShortTitle><LongTitle lims:inforce-start-date="2006-03-22" lims:fid="565911" lims:id="565911">Regulations Respecting Deleterious Substances in Liquid Effluents from Petroleum Refineries</LongTitle></Identification><Body lims:inforce-start-date="2006-03-22" lims:fid="565912" lims:id="565912"><Heading lims:inforce-start-date="2006-03-22" lims:fid="565913" lims:id="565913" level="1"><TitleText>Short Title</TitleText></Heading><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565914" lims:id="565914"><Label>1</Label><Text>These Regulations may be cited as the <XRefExternal reference-type="regulation" link="C.R.C.,_c._828">Petroleum Refinery Liquid Effluent Regulations</XRefExternal>.</Text></Section><Heading lims:inforce-start-date="2006-03-22" lims:fid="565915" lims:id="565915" level="1"><TitleText>Interpretation</TitleText></Heading><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565916" lims:id="565916"><Label>2</Label><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565917" lims:id="565917"><Label>(1)</Label><Text>In these Regulations,</Text><Definition lims:inforce-start-date="2006-03-22" lims:fid="565918" lims:id="565918" generate-in-text="no"><Text><DefinedTermEn>Act</DefinedTermEn> means the <XRefExternal reference-type="act" link="F-14">Fisheries Act</XRefExternal>; (<DefinedTermFr>Loi</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565919" lims:id="565919" generate-in-text="no"><Text><DefinedTermEn>actual deposit</DefinedTermEn> means the aggregate quantity, measured in pounds per day, of a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) that is contained in all liquid effluent and once-through cooling water and that is actually deposited in any one day by a refinery; (<DefinedTermFr>rejet réel</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565920" lims:id="565920" generate-in-text="no"><Text><DefinedTermEn>ammonia nitrogen</DefinedTermEn> means the nitrogen in ammonia that results from the operation of a refinery, that is contained in liquid effluent or once-through cooling water from that refinery and that is determined to be present therein by the test method referred to in item 4 of the table to Schedule IV; (<DefinedTermFr>azote ammoniacal</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565921" lims:id="565921" generate-in-text="no"><Text><DefinedTermEn>authorized deposit</DefinedTermEn> means the aggregate quantity, measured in pounds per day, of a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) that is contained in all liquid effluent and once-through cooling water and that may be deposited in any one day by a refinery under the authority of these Regulations; (<DefinedTermFr>rejet autorisé</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565922" lims:id="565922" generate-in-text="no"><Text><DefinedTermEn>ballast water</DefinedTermEn> means water, carried in a vessel for stability and seaworthiness, that is discharged from the vessel to a refinery prior to loading the vessel and includes water used for cargo or ballast tank cleaning; (<DefinedTermFr>eau de ballast</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565923" lims:id="565923" generate-in-text="no"><Text><DefinedTermEn>crude oil</DefinedTermEn> means virgin or naturally occurring unrefined petroleum and any hydrocarbons or mixture of hydrocarbons similar in composition to petroleum brought into a refinery for processing, but does not include hydrocarbons and residual fuels brought into a refinery primarily to meet the fuel requirements of that refinery or primarily for direct blending into finished products; (<DefinedTermFr>pétrole brut</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565924" lims:id="565924" generate-in-text="no"><Text><DefinedTermEn>day</DefinedTermEn> means a period of 24 consecutive hours; (<DefinedTermFr>jour</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565925" lims:id="565925" generate-in-text="no"><Text><DefinedTermEn>deposit</DefinedTermEn> means to deposit or permit the deposit in water frequented by fish; (<DefinedTermFr>rejeter</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565926" lims:id="565926" generate-in-text="no"><Text><DefinedTermEn>liquid effluent</DefinedTermEn> means, subject to subsection (3), waste water and includes process water, cooling tower blow-down, tank draining, ballast water, storm water, wastes from water treatment facilities and run-off from land used for the disposition of waste water and sludges associated with the operation of a refinery; (<DefinedTermFr>effluent</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565927" lims:id="565927" generate-in-text="no"><Text><DefinedTermEn>Minister</DefinedTermEn> means the Minister of the Environment; (<DefinedTermFr>ministre</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565928" lims:id="565928" generate-in-text="no"><Text><DefinedTermEn>oil and grease</DefinedTermEn> means the oil and grease that results from the operation of a refinery, that is contained in liquid effluent or once-through cooling water from that refinery and that is determined to be present therein by the test method referred to in item 1 of the table to Schedule IV; (<DefinedTermFr>huiles et graisses</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565929" lims:id="565929" generate-in-text="no"><Text><DefinedTermEn>once-through cooling water</DefinedTermEn> means, subject to subsection (3), water that has been circulated once through heat exchangers, either singly or in series, for the purpose of removing heat from process streams and that is not intended to come into contact with the process streams; (<DefinedTermFr>eau de refroidissement non recyclée</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565930" lims:id="565930" generate-in-text="no"><Text><DefinedTermEn>owner</DefinedTermEn> means the owner or operator of a refinery or his authorized representative; (<DefinedTermFr>propriétaire</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565931" lims:id="565931" generate-in-text="no"><Text><DefinedTermEn>phenols</DefinedTermEn> means the hydroxy derivatives of benzene and its condensed nuclei that result from the operation of a refinery, that are contained in liquid effluent or once-through cooling water from that refinery and that are determined to be present therein by the test method referred to in item 2 of the table to Schedule IV; (<DefinedTermFr>phénols</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565932" lims:id="565932" generate-in-text="no"><Text><DefinedTermEn>process water</DefinedTermEn> means water that is intended to come into contact with hydrocarbons or treating chemicals at a refinery; (<DefinedTermFr>eau de traitement</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565933" lims:id="565933" generate-in-text="no"><Text><DefinedTermEn>reference crude rate</DefinedTermEn> means the quantity of crude oil, expressed in thousand barrels per day, that, in accordance with section 6, has been declared by the owner of a refinery to be the reference crude rate of the refinery; (<DefinedTermFr>taux de référence de brut</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565934" lims:id="565934" generate-in-text="no"><Text><DefinedTermEn>refinery</DefinedTermEn> means facilities intended primarily for the separation and conversion of crude oil into products, including liquified petroleum gas, gasolines, naphthas, heating oils, fuel oils, asphalts, lubricating oils and greases, benzene, toluene, xylene, hydrogen, sulphur and coke, and includes blending, shipping and packaging facilities located on the refinery property and all properties developed for the operation of those facilities, but does not include facilities associated with the processing of natural gas or the production of synthetic petroleum originating from coal or bituminous sands; (<DefinedTermFr>raffinerie</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565935" lims:id="565935" generate-in-text="no"><Text><DefinedTermEn>storm water</DefinedTermEn> means, subject to subsection (2), water run-off that results from precipitation of any kind that falls on a refinery and includes water run-off originating from outside the refinery that passes over or through the refinery; (<DefinedTermFr>eaux pluviales</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565936" lims:id="565936" generate-in-text="no"><Text><DefinedTermEn>stream day crude rate</DefinedTermEn> means the rate, in barrels per day, at which crude oil is processed in a refinery; (<DefinedTermFr>taux de brut par jour de fonctionnement effectif</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565937" lims:id="565937" generate-in-text="no"><Text><DefinedTermEn>sulfide</DefinedTermEn> means dissolved sulfide that results from the operation of a refinery that is contained in liquid effluent or once-through water from that refinery and that is determined to be present therein by the test method referred to in item 3 of the table to Schedule IV; (<DefinedTermFr>sulfures</DefinedTermFr>)</Text></Definition><Definition lims:inforce-start-date="2006-03-22" lims:fid="565938" lims:id="565938" generate-in-text="no"><Text><DefinedTermEn>total suspended matter</DefinedTermEn> means the non-filterable residue that results from the operation of a refinery, that is contained in liquid effluent or once-through cooling water from that refinery and that is determined to be present therein by the test method referred to in item 5 of the table to Schedule IV. (<DefinedTermFr>matières en suspension de toute nature</DefinedTermFr>)</Text></Definition></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565939" lims:id="565939"><Label>(2)</Label><Text>When storm water is protected, in such manner as the Minister may approve in writing, from contamination by the deleterious substances prescribed in section 4 that originate from the refinery, the storm water shall be deemed not to be storm water for the purpose of these Regulations.</Text></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565940" lims:id="565940"><Label>(3)</Label><Text>When, prior to being deposited, liquid effluent or once-through cooling water has been treated, in such manner as the Minister may approve in writing, at a site outside a refinery for the purpose of removing therefrom the deleterious substances prescribed in section 4, the liquid effluent or once-through cooling water shall be deemed not to be liquid effluent or once-through cooling water for the purpose of these Regulations.</Text></Subsection></Section><Heading lims:inforce-start-date="2006-03-22" lims:fid="565941" lims:id="565941" level="1"><TitleText>Application</TitleText></Heading><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565942" lims:id="565942"><Label>3</Label><Text>These Regulations apply to every refinery that has not commenced the processing of crude oil prior to November 1, 1973 and that commences the processing of crude oil on or after that date.</Text></Section><Heading lims:inforce-start-date="2006-03-22" lims:fid="565943" lims:id="565943" level="1"><TitleText>Substances Prescribed as Deleterious Substances</TitleText></Heading><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565944" lims:id="565944"><Label>4</Label><Text>For the purpose of paragraph (c) of the definition <DefinedTermEn>deleterious substance</DefinedTermEn> in subsection 33(11) of the Act, the following substances are prescribed as deleterious substances;</Text><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565945" lims:id="565945"><Label>(a)</Label><Text>oil and grease;</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565946" lims:id="565946"><Label>(b)</Label><Text>phenols;</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565947" lims:id="565947"><Label>(c)</Label><Text>sulfide;</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565948" lims:id="565948"><Label>(d)</Label><Text>ammonia nitrogen;</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565949" lims:id="565949"><Label>(e)</Label><Text>total suspended matter; and</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565950" lims:id="565950"><Label>(f)</Label><Text>any substance capable of altering the pH of liquid effluent or once-through cooling water.</Text></Paragraph></Section><Heading lims:inforce-start-date="2006-03-22" lims:fid="565951" lims:id="565951" level="1"><TitleText>Authorized Deposit of a Deleterious Substance</TitleText></Heading><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565952" lims:id="565952"><Label>5</Label><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565953" lims:id="565953"><Label>(1)</Label><Text>Subject to these Regulations, the owner of a refinery may deposit a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) if</Text><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565954" lims:id="565954"><Label>(a)</Label><Text>the arithmetic mean of the actual deposits of each such substance during the month in which the deposit is made does not exceed the arithmetic mean of the authorized deposits of that substance in the same month for the refinery, as calculated in accordance with section 7;</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565955" lims:id="565955"><Label>(b)</Label><Text>the actual deposit of each such substance deposited in each day by the refinery does not exceed, for more than one day in each month, the authorized deposit of that substance for the refinery, as calculated in accordance with subsection 8(1); and</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565956" lims:id="565956"><Label>(c)</Label><Text>the actual deposit of each such substance deposited in each day by the refinery does not exceed the authorized deposit of that substance for the refinery as calculated in accordance with subsection 8(2).</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565957" lims:id="565957"><Label>(2)</Label><Text>Subject to these Regulations, the owner of a refinery may deposit the deleterious substance prescribed in paragraph 4(f) if the pH of the liquid effluent or once-through cooling water is within the limits of 6.0 and 9.5.</Text></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565958" lims:id="565958"><Label>(3)</Label><Text>Subject to these Regulations, the owner of a refinery may deposit a deleterious substance prescribed in paragraph 4(a), (b) or (e), if the aggregate quantity of that substance contained in storm water being deposited in any month does not exceed the limit of the deposit authorized of that substance in the same month for the refinery, as calculated in accordance with subsection 9(2).</Text></Subsection></Section><Heading lims:inforce-start-date="2006-03-22" lims:fid="565959" lims:id="565959" level="1"><TitleText>Reference Crude Rates</TitleText></Heading><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565960" lims:id="565960"><Label>6</Label><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565961" lims:id="565961"><Label>(1)</Label><Text>When the owner of a refinery intends to deposit a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e), he shall, before making the deposit, sign, date and forward to the Minister a declaration, in such form as the Minister may prescribe, stating the reference crude rate of the refinery.</Text></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565962" lims:id="565962"><Label>(2)</Label><Text>For the purpose of subsection (1), the reference crude rate of a refinery is the maximum design stream day crude rate of the refinery, divided by 1,000.</Text></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565963" lims:id="565963"><Label>(3)</Label><Text>The owner of a refinery may revise the reference crude rate of the refinery at any time by signing, dating and forwarding to the Minister a declaration, in such form as the Minister may prescribe, stating the revised reference crude rate of the refinery.</Text></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565964" lims:id="565964"><Label>(4)</Label><Text>The owner of a refinery that deposits a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) shall revise the reference crude rate of the refinery if the arithmetic mean of the stream day crude rates during any two consecutive months, divided by 1,000, excluding days when crude rates have been reduced due to refinery maintenance, is less than 85 per cent of the last declared reference crude rate of the refinery and shall sign, date and forward a declaration, in such form as the Minister may prescribe, stating the revised reference crude rate of the refinery.</Text></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565965" lims:id="565965"><Label>(5)</Label><Text>For the purpose of subsection (3), the revised reference crude rate of a refinery is the arithmetic mean of stream day crude rates sustained in commercial operation for at least seven consecutive days, divided by 1,000.</Text></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565966" lims:id="565966"><Label>(6)</Label><Text>For the purpose of subsection (4), the revised reference crude rate of a refinery is the arithmetic mean of stream day crude rates sustained in commercial operation for at least 14 consecutive days, divided by 1,000.</Text></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565967" lims:id="565967"><Label>(7)</Label><Text>The revised reference crude rate of a refinery takes effect on the first day of the month in which it is declared.</Text></Subsection></Section><Heading lims:inforce-start-date="2006-03-22" lims:fid="565968" lims:id="565968" level="1"><TitleText>Calculation of Authorized Deposits</TitleText></Heading><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565969" lims:id="565969"><Label>7</Label><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565970" lims:id="565970"><Label>(1)</Label><Text>For the purpose of paragraph 5(1)(a), the arithmetic mean of the authorized deposits for a refinery for a month shall be calculated using the amounts obtained in the calculations made under subsection (2).</Text></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565971" lims:id="565971"><Label>(2)</Label><Text>The authorized deposit for a refinery of a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) shall, subject to section 9, be calculated for each day by multiplying the amount in Column II of an item of Schedule I for the deleterious substance set out in Column I of that item by the reference crude rate of the refinery for that month.</Text></Subsection></Section><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565972" lims:id="565972"><Label>8</Label><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565973" lims:id="565973"><Label>(1)</Label><Text>For the purpose of paragraph 5(1)(b), the authorized deposit for a refinery of a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) shall, subject to section 9, be calculated by multiplying the amount set out in Column III of an item of Schedule I for the deleterious substance set out in Column I of that item by the reference crude rate of the refinery for that month.</Text></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565974" lims:id="565974"><Label>(2)</Label><Text>For the purpose of paragraph 5(1)(c), the authorized deposit for a refinery of a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) shall, subject to section 9, be calculated by multiplying the amount set out in Column IV of an item of Schedule I for the deleterious substance set out in Column I of that item by the reference crude rate of the refinery for that month.</Text></Subsection></Section><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565975" lims:id="565975"><Label>9</Label><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565976" lims:id="565976"><Label>(1)</Label><Text>When storm water is deposited by a refinery in any day, the authorized deposit for the refinery of a deleterious substance prescribed in paragraph 4(a), (b) or (e), calculated in accordance with sections 7 and 8, may be increased for that day by the amount set out in Column II of an item of Schedule II for the deleterious substance set out in Column I of that item for each 10,000 Canadian gallons of storm water that is deposited.</Text></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565977" lims:id="565977"><Label>(2)</Label><Text>The limit of the deposit authorized in pounds per month of a deleterious substance prescribed in paragraph 4(a), (b) or (e) contained in storm water being deposited by a refinery in any month shall be calculated by multiplying the amount set out in Column III of an item of Schedule II for the deleterious substance set out in Column I of that item by the reference crude rate of the refinery for that month.</Text></Subsection></Section><Heading lims:inforce-start-date="2006-03-22" lims:fid="565978" lims:id="565978" level="1"><TitleText>Calculation of Actual Deposits</TitleText></Heading><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565979" lims:id="565979"><Label>10</Label><Text>For the purposes of subsection 5(1), when the owner of a refinery deposits a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e), he shall, within 30 days after the end of the month in which the deposit is made, determine for that month the actual deposit of each substance deposited by the refinery by making the measurements and calculations in accordance with Schedule IV.</Text></Section><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565980" lims:id="565980"><Label>11</Label><Text>The owner of a refinery that deposits the deleterious substance prescribed in paragraph 4(f) shall, every day in the month during which the deposit is made or when requested by the Minister, monitor the deposit for the purpose of subsection 5(2) by performing the test referred to in Schedule III.</Text></Section><Heading lims:inforce-start-date="2006-03-22" lims:fid="565981" lims:id="565981" level="1"><TitleText>Reporting</TitleText></Heading><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565982" lims:id="565982"><Label>12</Label><Subsection lims:inforce-start-date="2006-03-22" lims:fid="565983" lims:id="565983"><Label>(1)</Label><Text>The owner of a refinery that has deposited a deleterious substance prescribed in section 4 in any month shall sign, date and forward to the Minister within 30 days after the end of that month or when requested by the Minister, a report, in such form as the Minister may prescribe, indicating</Text><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565984" lims:id="565984"><Label>(a)</Label><Text>the arithmetic mean of the authorized deposits of that substance in that month for the refinery as calculated in accordance with section 7 and, where applicable, section 9;</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565985" lims:id="565985"><Label>(b)</Label><Text>the authorized deposits of that substance in each day of that month for the refinery as calculated in accordance with sections 7 and 8 and, where applicable, section 9;</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565986" lims:id="565986"><Label>(c)</Label><Text>the actual deposits of the deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) deposited in each day of that month by the refinery as calculated in accordance with Schedule IV;</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565987" lims:id="565987"><Label>(d)</Label><Text>the arithmetic mean of the actual deposits of the deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) deposited in that month by the refinery as calculated in accordance with Schedule IV;</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565988" lims:id="565988"><Label>(e)</Label><Text>the pH of composite samples measured in accordance with Schedule III;</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565989" lims:id="565989"><Label>(f)</Label><Text>the reference crude rate of the refinery in that month; and</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="565990" lims:id="565990"><Label>(g)</Label><Text>such other information as may be requested by the Minister to enable him to determine whether the refinery is operating in compliance with the requirements of these Regulations.</Text></Paragraph></Subsection></Section><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565991" lims:id="565991"><Label>13</Label><Text>The owner of a refinery that deposits a deleterious substance prescribed in section 4 shall install and maintain facilities including sampling connections and flow-measuring devices that are acceptable to the Minister to enable the Minister to determine whether the refinery is operating in compliance with the requirements of these Regulations.</Text></Section></Body><Schedule lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="565992" lims:id="565992" spanlanguages="no" bilingual="no"><ScheduleFormHeading lims:inforce-start-date="2006-03-22" lims:fid="565993" lims:id="565993"><Label>SCHEDULE I</Label><OriginatingRef>(Sections 7 and 8)</OriginatingRef></ScheduleFormHeading><TableGroup lims:inforce-start-date="2006-03-22" lims:fid="565994" lims:id="565994" pointsize="7" topmarginspacing="10" rowbreak="no" bilingual="no" spanlanguages="no"><table lims:inforce-start-date="2006-03-22" lims:fid="565995" lims:id="565995" frame="topbot"><title lims:inforce-start-date="2006-03-22" lims:fid="565996" lims:id="565996">Amounts To Be Used in Calculating Authorized Deposits of Deleterious Substances</title><tgroup lims:inforce-start-date="2006-03-22" lims:fid="565997" lims:id="565997" cols="5"><colspec colname="1" colwidth="36.27*" /><colspec colname="2" colwidth="96.00*" /><colspec colname="3" colwidth="109.81*" /><colspec colname="4" colwidth="107.95*" /><colspec colname="5" colwidth="117.99*" /><thead lims:inforce-start-date="2006-03-22" lims:fid="565998" lims:id="565998"><row topdouble="yes" topmarginspacing="4"><entry colsep="0" rowsep="0" valign="top" /><entry colsep="0" rowsep="0" valign="top">Column I</entry><entry colsep="0" rowsep="0" valign="top">Column II</entry><entry colsep="0" rowsep="0" valign="top">Column III</entry><entry colsep="0" rowsep="0" valign="top">Column IV</entry></row><row valign="bottom"><entry colsep="0" rowsep="1">Item</entry><entry colsep="0" rowsep="1">Name of Deleterious Substance</entry><entry colsep="0" rowsep="1">Monthly amount in pounds per 1,000 barrels of crude oil</entry><entry colsep="0" rowsep="1">One day amount in pounds per 1,000 barrels of crude oil</entry><entry colsep="0" rowsep="1">Maximum daily amount in pounds per 1,000 barrels of crude oil</entry></row></thead><tbody lims:inforce-start-date="2006-03-22" lims:fid="565999" lims:id="565999"><row><entry colsep="0" rowsep="0">1</entry><entry rowheader="yes" colsep="0" rowsep="0">Oil and Grease</entry><entry colsep="0" rowsep="0">3.0</entry><entry colsep="0" rowsep="0">5.5</entry><entry colsep="0" rowsep="0">7.5</entry></row><row><entry colsep="0" rowsep="0">2</entry><entry rowheader="yes" colsep="0" rowsep="0">Phenols</entry><entry colsep="0" rowsep="0">0.3</entry><entry colsep="0" rowsep="0">0.55</entry><entry colsep="0" rowsep="0">0.75</entry></row><row><entry colsep="0" rowsep="0">3</entry><entry rowheader="yes" colsep="0" rowsep="0">Sulfide</entry><entry colsep="0" rowsep="0">0.1</entry><entry colsep="0" rowsep="0">0.3</entry><entry colsep="0" rowsep="0">0.5</entry></row><row><entry colsep="0" rowsep="0">4</entry><entry rowheader="yes" colsep="0" rowsep="0">Ammonia Nitrogen</entry><entry colsep="0" rowsep="0">3.6</entry><entry colsep="0" rowsep="0">5.7</entry><entry colsep="0" rowsep="0">7.2</entry></row><row><entry colsep="0" rowsep="0">5</entry><entry rowheader="yes" colsep="0" rowsep="0">Total Suspended Matter</entry><entry colsep="0" rowsep="0">7.2</entry><entry colsep="0" rowsep="0">12.0</entry><entry colsep="0" rowsep="0">15.0</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="566000" lims:id="566000" spanlanguages="no" bilingual="no"><ScheduleFormHeading lims:inforce-start-date="2006-03-22" lims:fid="566001" lims:id="566001"><Label>SCHEDULE II</Label><OriginatingRef>(Section 9)</OriginatingRef></ScheduleFormHeading><TableGroup lims:inforce-start-date="2006-03-22" lims:fid="566002" lims:id="566002" pointsize="7" topmarginspacing="10" rowbreak="no" bilingual="no" spanlanguages="no"><table lims:inforce-start-date="2006-03-22" lims:fid="566003" lims:id="566003" frame="topbot"><title lims:inforce-start-date="2006-03-22" lims:fid="566004" lims:id="566004">Amounts To Be Used in Calculating Additional Authorized Deposits of Deleterious Substances when Storm Water is Being Discharged and Limits of Deposits Authorized</title><tgroup lims:inforce-start-date="2006-03-22" lims:fid="566005" lims:id="566005" cols="4"><colspec colname="1" colwidth="42.67*" /><colspec colname="2" colwidth="139.18*" /><colspec colname="3" colwidth="145.94*" /><colspec colname="4" colwidth="140.19*" /><thead lims:inforce-start-date="2006-03-22" lims:fid="566006" lims:id="566006"><row topdouble="yes" topmarginspacing="4"><entry colsep="0" rowsep="0" valign="top" /><entry colsep="0" rowsep="0" valign="top">Column I</entry><entry colsep="0" rowsep="0" valign="top">Column II</entry><entry colsep="0" rowsep="0" valign="top">Column III</entry></row><row valign="bottom"><entry colsep="0" rowsep="1">Item</entry><entry colsep="0" rowsep="1">Name of Deleterious Substance</entry><entry colsep="0" rowsep="1">Pounds per 10,000 Canadian Gallons of Storm Water</entry><entry colsep="0" rowsep="1">Pounds per month per 1,000 barrels of crude oil per day</entry></row></thead><tbody lims:inforce-start-date="2006-03-22" lims:fid="566007" lims:id="566007"><row><entry colsep="0" rowsep="0">1</entry><entry rowheader="yes" colsep="0" rowsep="0">Oil and Grease</entry><entry colsep="0" rowsep="0">1.0</entry><entry colsep="0" rowsep="0">25.0</entry></row><row topmarginspacing="8"><entry colsep="0" rowsep="0">2</entry><entry rowheader="yes" colsep="0" rowsep="0">Phenols</entry><entry colsep="0" rowsep="0">0.1</entry><entry colsep="0" rowsep="0">2.5</entry></row><row topmarginspacing="8"><entry colsep="0" rowsep="0">3</entry><entry rowheader="yes" colsep="0" rowsep="0">Total Suspended Matter</entry><entry colsep="0" rowsep="0">3.0</entry><entry colsep="0" rowsep="0">75.0</entry></row></tbody></tgroup></table></TableGroup></Schedule><Schedule lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="566008" lims:id="566008" spanlanguages="no" bilingual="no"><ScheduleFormHeading lims:inforce-start-date="2006-03-22" lims:fid="566009" lims:id="566009"><Label>SCHEDULE III</Label><OriginatingRef>(Sections 11, 12 and Schedule IV)</OriginatingRef><TitleText>Measurement of pH</TitleText></ScheduleFormHeading><RegulationPiece lims:inforce-start-date="2006-03-22" lims:fid="566010" lims:id="566010"><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="566011" lims:id="566011"><Label>1</Label><Text>The pH of composite samples obtained from each liquid effluent outfall and from the once-through cooling water shall be determined using</Text><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="566012" lims:id="566012"><Label>(a)</Label><Text>the test method prescribed in section 221 of the publication <XRefExternal reference-type="standard">Standard Methods for the Examination of Water and Waste Water</XRefExternal>, 13th edition (1971), published jointly by the American Public Health Association, American Water Works Association and the Water Pollution Control Federation; or</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="566013" lims:id="566013"><Label>(b)</Label><Text>another equivalent method, approved in writing by the Minister, the results of which can be confirmed by the method referred to in paragraph (a).</Text></Paragraph></Section><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="566014" lims:id="566014"><Label>2</Label><Text>For the purpose of section 1, <DefinedTermEn>composite sample</DefinedTermEn> has the same meaning as in subsection 2(2) of Schedule IV.</Text></Section></RegulationPiece></Schedule><Schedule lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="566015" lims:id="566015" spanlanguages="no" bilingual="no"><ScheduleFormHeading lims:inforce-start-date="2006-03-22" lims:fid="566016" lims:id="566016"><Label>SCHEDULE IV</Label><OriginatingRef>(Sections 2, 10 and 12)</OriginatingRef><TitleText>Measurement and Calculation of Actual Deposit of a Deleterious Substance Prescribed in Paragraph 4(a), (b), (c), (d) or (e) of Regulations</TitleText></ScheduleFormHeading><RegulationPiece lims:inforce-start-date="2006-03-22" lims:fid="566017" lims:id="566017"><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="566018" lims:id="566018"><Label>1</Label><Text>The flow rates of all liquid effluents and once-through cooling water deposited by a refinery shall be measured and recorded continuously in Canadian gallons per minute.</Text></Section><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="566019" lims:id="566019"><Label>2</Label><Subsection lims:inforce-start-date="2006-03-22" lims:fid="566020" lims:id="566020"><Label>(1)</Label><Text>The concentration in milligrams per litre of a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) in composite samples obtained from each liquid effluent outfall and from the once-through cooling water shall be determined every Monday, Wednesday and Friday, or as requested by the Minister, using</Text><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="566021" lims:id="566021"><Label>(a)</Label><Text>the test method referred to in Column II of an item of the table to this Schedule and modified as set out in Column III of that item in respect of the deleterious substance set out in Column I of that item; or</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="566022" lims:id="566022"><Label>(b)</Label><Text>any other equivalent method, approved in writing by the Minister, the results of which can be confirmed by the method referred to in paragraph (a).</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="566023" lims:id="566023"><Label>(2)</Label><Text>For the purpose of subsection (1), a composite sample is</Text><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="566024" lims:id="566024"><Label>(a)</Label><Text>the quantity of liquid effluent or once-through cooling water that is collected continually during a sampling period of 24 hours at a rate in proportion to the flow rate of the liquid effluent or once-through cooling water;</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="566025" lims:id="566025"><Label>(b)</Label><Text>the quantity of liquid effluent or once-through cooling water that is collected so that a minimum of 96 equal volumes of liquid are delivered into a receptacle at equal time intervals over a sampling period of 24 hours; or</Text></Paragraph><Paragraph lims:inforce-start-date="2006-03-22" lims:fid="566026" lims:id="566026"><Label>(c)</Label><Text>in the case where the use of continuous stream analyzers have been approved by the Minister, the liquid effluent or once-through cooling water itself.</Text></Paragraph></Subsection><Subsection lims:inforce-start-date="2006-03-22" lims:fid="566027" lims:id="566027"><Label>(3)</Label><Text>For the purpose of this section, procedures pertaining to sampling, the preservation and storage of samples and the prevention of interference, as outlined in the general sections relating to the specific test methods set out in Column II of the table to this Schedule, should be adhered to.</Text></Subsection></Section><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="566028" lims:id="566028"><Label>3</Label><Text>The actual deposit by a refinery of a deleterious substance prescribed in paragraph 4(a), (b), (c), (d) or (e) shall be calculated by using the amounts obtained under sections 1 and 2 of this Schedule for each day that the concentration of that deleterious substance has been determined.</Text></Section><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="566029" lims:id="566029"><Label>4</Label><Text>The arithmetic mean of the actual deposits referred to in paragraph 5(1)(a) of the Regulations shall be calculated using the amounts obtained under section 3 of this Schedule.</Text></Section><Section lims:inforce-start-date="2006-03-22" lims:lastAmendedDate="2006-03-22" lims:fid="566030" lims:id="566030"><Label>5</Label><Text>For the purpose of subsection 5(3) of the Regulations, the actual quantity of a deleterious substance prescribed in paragraph 4(a), (b) or (e) of the Regulations contained in storm water deposited each month shall be calculated using the weighted average concentration, based on the quantity of storm water discharged for those days during which the concentration of that deleterious substance has been determined, and the total quantity of storm water discharged in that month.</Text></Section></RegulationPiece><Heading lims:inforce-start-date="2006-03-22" lims:fid="566031" lims:id="566031" level="1"><Label>TABLE</Label><OriginatingRef>(Section 2)</OriginatingRef></Heading><TableGroup lims:inforce-start-date="2006-03-22" lims:fid="566032" lims:id="566032" pointsize="8" topmarginspacing="10" rowbreak="no" bilingual="no" spanlanguages="no"><table lims:inforce-start-date="2006-03-22" lims:fid="566033" lims:id="566033" frame="topbot"><title lims:inforce-start-date="2006-03-22" lims:fid="566034" lims:id="566034">Analytical Test Methods for Determining Presence and Concentrations of Deleterious Substances in Liquid Effluent and Once-Through Cooling Water</title><tgroup lims:inforce-start-date="2006-03-22" lims:fid="566035" lims:id="566035" cols="4"><colspec colname="1" colwidth="48.82*" /><colspec colname="2" colwidth="120.44*" /><colspec colname="3" colwidth="122.73*" /><colspec colname="4" colwidth="176.00*" /><thead lims:inforce-start-date="2006-03-22" lims:fid="566036" lims:id="566036"><row topdouble="yes" topmarginspacing="8"><entry colsep="0" rowsep="0" valign="top" /><entry colsep="0" rowsep="0" valign="top">Column I</entry><entry colsep="0" rowsep="0" valign="top">Column II</entry><entry colsep="0" rowsep="0" valign="top">Column III</entry></row><row valign="bottom"><entry colsep="0" rowsep="1">Item</entry><entry colsep="0" rowsep="1">Name of Deleterious Substance</entry><entry colsep="0" rowsep="1">Test Method</entry><entry colsep="0" rowsep="1">Remarks</entry></row></thead><tbody lims:inforce-start-date="2006-03-22" lims:fid="566037" lims:id="566037"><row><entry colsep="0" rowsep="0">1</entry><entry rowheader="yes" colsep="0" rowsep="0">Oil and grease</entry><entry colsep="0" rowsep="0">APHA<FootnoteRef idref="footnote1star_e">*</FootnoteRef>, Section 137</entry><entry colsep="0" rowsep="0">In 4 (a)<FootnoteRef idref="footnote2star_e">**</FootnoteRef> use petroleum ether as the solvent; in 4 (c)<FootnoteRef idref="footnote2star_e">**</FootnoteRef> dry on a steam bath at 100 °C.</entry></row><row topmarginspacing="8"><entry colsep="0" rowsep="0">2</entry><entry rowheader="yes" colsep="0" rowsep="0">Phenols</entry><entry colsep="0" rowsep="0">APHA<FootnoteRef idref="footnote1star_e">*</FootnoteRef>, Section 222B and C</entry><entry colsep="0" rowsep="0" /></row><row topmarginspacing="8"><entry colsep="0" rowsep="0">3</entry><entry rowheader="yes" colsep="0" rowsep="0">Sulfide</entry><entry colsep="0" rowsep="0">APHA<FootnoteRef idref="footnote1star_e">*</FootnoteRef>, Section 228C(b)</entry><entry colsep="0" rowsep="0">This test may be carried out on a filtered sample.</entry></row><row topmarginspacing="8"><entry colsep="0" rowsep="0">4</entry><entry rowheader="yes" colsep="0" rowsep="0">Ammonia nitrogen</entry><entry colsep="0" rowsep="0">APHA<FootnoteRef idref="footnote1star_e">*</FootnoteRef>, Section 212</entry><entry colsep="0" rowsep="0" /></row><row topmarginspacing="8"><entry colsep="0" rowsep="1">5</entry><entry rowheader="yes" colsep="0" rowsep="1">Total suspended matter</entry><entry colsep="0" rowsep="1">APHA<FootnoteRef idref="footnote1star_e">*</FootnoteRef>, Section 224C</entry><entry colsep="0" rowsep="1">During periods when storm water is being deposited, the volatile portion of total suspended matter determined by APHA<FootnoteRef idref="footnote1star_e">*</FootnoteRef> Section 224D may be substituted for APHA<FootnoteRef idref="footnote1star_e">*</FootnoteRef> Section 224C.</entry></row></tbody></tgroup></table><Footnote id="footnote1star_e" placement="table" status="official"><Label> *</Label><Text>Refers to the publication <XRefExternal reference-type="standard">Standard Methods for the Examination of Water and Waste Water</XRefExternal>, 13th edition, (1971), published jointly by the American Public Health Association, American Water Works Association and the Water Pollution Control Federation.</Text></Footnote><Footnote id="footnote2star_e" placement="table" status="official"><Label>**</Label><Text>Refers to section of test method.</Text></Footnote></TableGroup></Schedule></Regulation>