Specifications Relating to Timber Dimension Measuring Devices (SI/2024-48)
Full Document:
Regulations are current to 2026-06-21
Marginal note:Marking — general
29 (1) The following information must be permanently marked in a clearly visible location on a timber dimension measuring device or on a descriptive plate that is affixed to the device:
(a) the approval number assigned to the class, type or design of the device in accordance with paragraph 17(c) of the Weights and Measures Regulations;
(b) the name of the device’s manufacturer;
(c) the device’s model designation;
(d) the device’s serial number;
(e) for each axis of measurement that the device is capable of measuring in the location where it is installed,
(i) the minimum and maximum dimensions for each measuring range on that axis, and
(ii) the interval for each measuring range on that axis;
(f) the number of scan heads installed on the device;
(g) the device’s minimum and maximum operating speeds as installed;
(h) the minimum distance, in centimetres or metres, between each log measured; and
(i) the temperature range specified for the device by the manufacturer, if any.
Marginal note:Marking — temperature range
(2) Despite paragraph (1)(i), a temperature range specified for the device by the manufacturer must not be marked on it or the descriptive plate unless the range spans at least 30°C and is entirely within the default temperature range.
Page Details