Propane Dispenser Specifications (SI/91-110)

Regulations are current to 2026-05-26

  •  (1) The temperature sensor of the electronic ATC and the test thermal well of a propane dispenser shall be installed adjacent to each other

    • (a) in the meter chamber;

    • (b) in the vapour separator housing; or

    • (c) in the inlet or outlet piping to the meter.

  • (2) A temperature sensor referred to in subsection (1) shall be installed so that

    • (a) the sensing end of the sensor is in the main flow of liquid;

    • (b) the sensor is located no more than 0.5 m from the meter as measured along the piping; and

    • (c) no valves, pumps, flow-control valves or other equipment that may alter the temperature of the liquid are located between the meter chamber and the sensor.