  1. Greenhouse Gas Emissions Information Production Order - SOR/2018-214 (SCHEDULE 1 : Content of Annual Report on Emissions and Production)
    Greenhouse Gas Emissions Information Production Order

    [...]

    1 The following information respecting the person responsible for a regulated facility:

    • (a) an indication as to whether they are the owner or operator of the facility and their name and civic address;

    2 The following information respecting the regulated facility:

    • [...]

    • (g) in the case of an automotive facility, the combined floor area of all buildings in the facility as of December 31st of the calendar year, measured between the exterior walls of each of the buildings, expressed in square meters, and all methods and data used to calculate the combined floor area.

    [...]

    7 If thermal energy is sold, the following information for each regulated facility to which the thermal energy was sold:

    • [...]

    • (b) the quantity of thermal energy sold in the calendar year, expressed in gigajoules, as well as the thermal energy’s temperature, pressure and ratio of heat from the combustion of fossil fuel.

    8 If thermal energy is bought, the following information for each regulated facility from which the thermal energy was bought:

    • [...]

    • (b) the quantity of thermal energy bought in the calendar year, expressed in gigajoules, as well as the thermal energy’s temperature and pressure, if applicable, and ratio of heat from the combustion of fossil fuel.

    [...]


  2. Greenhouse Gas Emissions Information Production Order - SOR/2018-214 (Section 103)
    Greenhouse Gas Emissions Information Production Order
    Marginal note:Electricity production
    • [...]

    • (2) If a regulated facility uses a mixture of fossil fuels or a mixture of biomass and fossil fuels to generate electricity, the gross electricity generated by the facility is to be determined separately for the gaseous fuels, liquid fuels and solid fuels, in accordance with the following formula and expressed in GWh

      [...]

      where

      GU 
      is the gross quantity of electricity generated by the regulated facility in the calendar year
      • (a) as measured using meters that comply with the requirements of the Electricity and Gas Inspection Act and the Electricity and Gas Inspection Regulations, expressed in gigawatt hours, or

      • (b) for the 2019 calendar year, if the facility produces electricity using equipment or stationary items that do not have a meter that complies with the requirements specified in paragraph (a), as determined using data recorded in an operations log, expressed in gigawatt hours;

      HFFk 
      is determined in accordance with the following formula, calculated separately for gaseous fuels, liquid fuels and solid fuels “k”:

      [...]

      where:

      QFFj 
      is the quantity of gaseous, liquid or solid fuel, as the case may be, type “j” combusted in the facility for electricity generation during the calendar year, as determined under subsection (3) and in accordance with GHGRP 2.C.2 of,
      HHVj 
      is the higher heating value of the gaseous, liquid or solid fuel, as the case may be, type “j” combusted in the facility for electricity generation in accordance with GHGRP 2.C.1 and 2.C.3 of, and

    [...]


  3. Greenhouse Gas Emissions Information Production Order - SOR/2018-214 (Section 20)
    Greenhouse Gas Emissions Information Production Order
    Marginal note:Content of verification report
    •  (1) A verification report must be prepared by the verification body in relation to the annual report and any related records, and must include

      • [...]

      • (b) a verification statement with respect to the quantification of a regulated facility’s reported GHG emissions for the calendar year in respect of which the annual report was made, as referred to in paragraph 3(o) of Schedule 2; and

      • (c) a verification statement with respect to the quantification of a regulated facility’s production of each product that must be quantified under this Order for the calendar year in respect of which the annual report was made, as referred to in paragraph 3(p) of Schedule 2.

    • (2) For the purpose of the verification of a regulated facility’s annual report, a material discrepancy exists when,

      • (a) with respect to GHG emissions from regulated facilities that have an annual quantity of emissions of GHG of less than 500 kt of CO2e,

        • (i) in the case of each error or omission respecting GHG emissions, that is identified during the verification and that may be quantified, the result, determined in accordance with the following formula, is equal to or greater than 5%:

          A/B × 100

          where

          A 
          is the overstatement or understatement resulting from the error or omission, as an absolute value, expressed in tonnes of CO2e, and
      • (b) with respect to GHG emissions from regulated facilities that have an annual quantity of emissions of GHG that is equal to or greater than 500 kt of CO2e,

        • (i) in the case each single error or omission respecting GHG emissions, that is identified during the verification and that may be quantified, the result, determined in accordance with the following formula, is equal to or greater than 2%:

          A/B × 100

          where

          A 
          is the overstatement or understatement resulting from an error or omission, as an absolute value, expressed in tonnes of CO2e, and
      • (c) with respect to each product that must be quantified under this Order, in the case an error or omission that is identified during the verification and that may be quantified respecting the quantification of the product, the result, determined in accordance with the following formula is equal to or greater than 0.1%:

        A/B × 100

        where

        A 
        is the overstatement or understatement resulting from an error or omission, as an absolute value, expressed in the applicable unit of measure, and

    [...]


  4. Greenhouse Gas Emissions Information Production Order - SOR/2018-214 (SCHEDULE 2 : Content of Verification Report)
    Greenhouse Gas Emissions Information Production Order

    [...]

    1 The following information respecting the person responsible for a regulated facility:

    • (a) an indication as to whether they are the owner or operator of the facility and their name and civic address;

    [...]

    3 The following information respecting the verification:

    • [...]

    • (g) the total greenhouse gas emissions from all industrial activity for the regulated facility for the calendar year and the amount of each type of product produced by the regulated facility, as described in the annual report for the regulated facility;

    • (h) in the case of a verification of an electricity generation facility, the following information as described in the annual report :

      [...]

    • [...]

    • (j) a record of any corrections made by the person responsible as a result of the identification of any errors or omissions identified during the verification;

    [...]


  5. Greenhouse Gas Emissions Information Production Order - SOR/2018-214 (Section 56)
    Greenhouse Gas Emissions Information Production Order
    Marginal note:Production — fossil fuel
    • [...]

    • (2) Subject to section 57, if a unit uses a mixture of fossil fuels or a mixture of biomass and fossil fuels to generate electricity, the gross electricity generated by the unit is to be determined separately for the gaseous fuels, liquid fuels and solid fuels, in accordance with the following formula and expressed in GWh:

      [...]

      where

      GU 
      is the gross quantity of electricity generated by the unit in the calendar year, as measured at the electrical terminals of the generators of the unit using meters that comply with the requirements of the Electricity and Gas Inspection Act and the Electricity and Gas Inspection Regulations, expressed in GWh;
      HFFk 
      is determined in accordance with the following formula, calculated separately for gaseous fuels, liquid fuels and solid fuels “k”:

      [...]

      where:

      QFFj 
      is the quantity of gaseous, liquid or solid fuel, as the case may be, type “j” combusted in the unit during the calendar year, determined in accordance with subsection (3)
      HHVj 
      is the higher heating value of the gaseous, liquid or solid fuel, as the case may be, type “j” combusted in the unit. Each HHVj is determined in accordance with subsection 24(1) of the Reduction of Carbon Dioxide Emissions from Coal-fired Generation of Electricity Regulations, and
      j 
      is the jth fossil fuel type combusted in the unit during the calendar year, where “j” goes from 1 to m and where m is the number of types of gaseous, liquid or solid fuel, as the case may be, combusted; and


Date modified: