Government of Canada / Gouvernement du Canada
Symbol of the Government of Canada

Search

Energy Efficiency Regulations, 2016

Version of section 107 from 2022-12-21 to 2024-11-26:


Marginal note:Definitions

 The following definitions apply in this Division.

CSA C656-05

CSA C656-05 means the CSA standard CAN/CSA-C656-05 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-05)

CSA C656-14

CSA C656-14 means the CSA standard CSA-C656-14 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-14)

CSA C746-06

CSA C746-06 means the CSA standard CAN/CSA-C746-06 entitled Performance Standard for Rating Large and Single Packaged Vertical Air Conditioners and Heat Pumps. (CSA C746-06)

CSA C746-98

CSA C746-98 means the CSA standard CAN/CSA-C746-98 entitled Performance Standard for Rating Large Air Conditioners and Heat Pumps. (CSA C746-98)

small-duct and high-velocity

small-duct and high-velocity, with respect to a single package central air conditioner or a split-system central air conditioner, means one that has an indoor blower and coil combination that

  • (a) produces at least 300 Pa (1.2 inches of water) external static pressure when operated at an air volume rate of 104 to 165 L/s (220 to 350 cubic feet/minute) per nominal ton of cooling; and

  • (b) uses room outlets that produce velocities greater than 5 m/s (1,000 feet/minute) and that each have an area less than 39 cm2 (6 square inches). (à grand débit et à petits conduits)

space-constrained

space-constrained, with respect to a single package central air conditioner or a split system central air conditioner, means one that

  • (a) has a cooling capacity that is less than or equal to 8.79 kW (30,000 Btu/h); and

  • (b) has an outdoor or indoor unit that has an overall displacement or at least two overall exterior dimensions that

    • (i) are substantially smaller than those of other units of a similar cooling capacity that are usually installed in single family homes, and

    • (ii) if increased, would result in a considerable increase in the usual cost of installation or in a significant loss in the utility of the product to the consumer. (à espace restreint)

10 C.F.R. Appendix M

10 C.F.R. Appendix M means Appendix M to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M 10 C.F.R)

10 C.F.R. Appendix M1

10 C.F.R. Appendix M1 means Appendix M1 to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M1 10 C.F.R.)

  • SOR/2019-163, s. 14
  • SOR/2022-265, s. 3

Date modified: