Government of Canada / Gouvernement du Canada
Symbol of the Government of Canada

Search

Energy Efficiency Regulations, 2016

Version of section 755 from 2023-06-21 to 2024-11-26:


Marginal note:Energy efficiency standards

  •  (1) The energy efficiency standards set out in the applicable table in paragraph (a) of 10 C.F.R. §431.446 apply to a small motor.

  • Marginal note:Testing standard

    (2) A small electric motor complies with the energy efficiency standard if it meets that standard when

    • (a) the product’s average full load efficiency is determined using horsepower and kilowatt ratings that are determined in accordance with paragraph (b) of 10 C.F.R. §431.446;

    • (b) the product is tested at 100% of its nominal full load; and

    • (c) the product is tested in accordance with testing procedures established by one of the following standards that are applicable to a small electric motor as defined in section 753:

      • (i) if the motor is polyphase and has a nominal output power ≥ 0.18 kW (0.25 horsepower) but ≤ 0.75 kW (1 horsepower), CSA C747-09, IEEE 112 (Test Method A) or IEC 60034-2-1 (Test Method 2-1-1A),

      • (ii) if the motor is polyphase and has a nominal output power > 0.75 kW (1 horsepower) but ≤ 2.2 kW (3 horsepower), CSA C390-10, IEEE 112 (Test Method B) or IEC 60034-2-1 (Test Method 2-1-1B), or

      • (iii) if the motor is capacitor-start capacitor-run or capacitor-start induction-run, CSA C747-09, IEEE 114-2010 or IEC 60034-2-1 (Test Method 2-1-1A).

  • SOR/2018-201, s. 80
  • SOR/2022-265, s. 45

Date modified: