Explosives Regulations, 2013
Marginal note:Structural requirements
93 (1) Every mobile process unit must be designed and constructed to conform to good engineering practices. It must be constructed in a manner that prevents the accumulation of Footnote *explosives or raw material in cracks and cavities and that minimizes the harm to people and property that could result from an ignition of the explosives or raw material. The construction materials must be Footnote *compatible with the explosives to be manufactured and transported and with the raw material to be used.
Marginal note:Means of escape
(2) Every mobile process unit must have a means of escape that will permit all people in the unit to leave it quickly and easily in an emergency.
Marginal note:Equipment
(3) All tools, equipment, hoses and hydraulic systems in or on a mobile process unit must be designed, constructed and installed to conform to good engineering practices.
Marginal note:Compatibility
(4) Every thing that is in or on a mobile process unit must be made from materials that are compatible with the explosives and raw material with which they could come into contact during manufacturing operations.
Marginal note:Control of safety-critical parameters
(5) All equipment designed to control safety-critical parameters on pumps, and on other process equipment that puts energy into explosives, must be installed and maintained in good condition so that the equipment operates while the pumps and process equipment are in use.
Return to footnote *Terms preceded by an asterisk are defined in section 6.
- Date modified: