Multi-Sector Air Pollutants Regulations

Version of section 44 from 2016-06-17 to 2025-11-20:


Marginal note:Record-making

 Records in respect of a boiler or heater that contain the following information and documents must be made:

  • (a) a description of the steps, including the relevant dates, that are taken to comply with the operation and maintenance specifications for the boiler or heater set out by its manufacturer or required by its design;

  • (b) a description, including the relevant dates, of any modifications that are made to the design or characteristics of the boiler and heater, including

    • (i) a redesign referred to in subsection 10(2),

    • (ii) a major modification referred to in subsection 13(2),

    • (iii) for a heater, the addition or removal of equipment to preheat air,

    • (iv) the refurbishment of a burner, and

    • (v) a modification that results in a change in its thermal efficiency;

  • (c) the following information necessary to determine the percentage of the input energy in the boiler’s or heater’s combustion chamber that results from the introduction of gaseous fossil fuel in accordance with the formula set out in section 15:

    • (i) if the value determined for each of Eo and Eh is zero, information that establishes that the boiler or heater combusted only gaseous fossil fuel, and

    • (ii) in any other case, information necessary to determine the value of each of Ecng, Egff, Eo and Eh in that formula; and

  • (d) an indication of a change in fuel from alternative gas to natural gas, or vice versa, including the date and hour of the change, along with supporting documents necessary to determine the value of an element of the formula set out in section 16.