Energy Efficiency Regulations, 2016
Marginal note:Energy efficiency standards — single-phase
134 (1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase split-system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.
Marginal note:Energy efficiency standards — three-phase
(1.1) The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase split-system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.
Marginal note:Testing standard
(2) A split-system central air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a split-system central air conditioner as defined in section 132.
Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Split system central air conditioners, other than those that are small-duct and high-velocity CSA C656-14 for seasonal energy efficiency ratio
10 C.F.R. Appendix M for off mode power consumption
Seasonal energy efficiency ratio ≥ 13.0
Off mode power consumption ≤ 30 W
On or after February 3, 1995 and before January 1, 2023 2 Split system central air conditioners that are small-duct and high-velocity CSA C656-14 for seasonal energy efficiency ratio
10 C.F.R. Appendix M for off mode power consumption
Seasonal energy efficiency ratio ≥ 12.0
Off mode power consumption ≤ 30 W
On or after February 3, 1995 and before January 1, 2023 3 Split system central air conditioners, other than those that are space-constrained or small-duct and high-velocity 10 C.F.R. Appendix M1 Seasonal energy efficiency ratio 2 ≥ 13.4
Off mode power consumption ≤ 30 W
On or after January 1, 2023 4 Split system central air conditioners that are small-duct and high-velocity 10 C.F.R. Appendix M1 Seasonal energy efficiency ratio 2 ≥ 12.0
Off mode power consumption ≤ 30 W
On or after January 1, 2023 5 Split system central air conditioners that are space-constrained 10 C.F.R. Appendix M1 Seasonal energy efficiency ratio 2 ≥ 11.7
Off mode power consumption ≤ 30 W
On or after January 1, 2023 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Split system central air conditioners, other than those that are small-duct and high-velocity CSA C656-14 Seasonal energy efficiency ratio ≥ 13.0 On or after February 3, 1995 2 Split system central air conditioners that are small-duct and high-velocity CSA C656-14 Seasonal energy efficiency ratio ≥ 12.0 On or after February 3, 1995
- SOR/2019-163, s. 25
- SOR/2022-265, s. 10
- Date modified: