Government of Canada / Gouvernement du Canada
Symbol of the Government of Canada

Search

Energy Efficiency Regulations, 2016

Version of section 213 from 2022-12-21 to 2024-06-11:


Marginal note:Energy efficiency standards — single-phase

  •  (1) The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase split system central heat pumps described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Energy efficiency standards — three-phase

    (1.1) The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase split system central heat pumps described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard

    (2) A split system central heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a split system central heat pump as defined in section 211.

    TABLE 1

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture
    1Split system central heat pumps, other than those that are small-duct and high-velocity

    CSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor

    10 C.F.R. Appendix M for off mode power consumption

    Seasonal energy efficiency ratio ≥ 14.0

    Heating seasonal performance factor (Region V) ≥ 7.1

    Off mode power consumption ≤ 33 W

    On or after December 31, 1998 and before January 1, 2023
    2Split system central heat pumps that are small-duct and high-velocity

    CSA C656-14 for seasonal energy efficiency ratio and heating seasonal performance factor

    10 C.F.R. Appendix M for off mode power consumption

    Seasonal energy efficiency ratio ≥ 12.0

    Heating seasonal performance factor (Region V) ≥ 6.3

    Off mode power consumption ≤ 30 W

    On or after December 31, 1998 and before January 1, 2023
    3Split system central heat pumps, other than those that are small-duct and high-velocity or space-constrained10 C.F.R. Appendix M1

    Seasonal energy efficiency ratio 2 ≥ 14.3

    Heating seasonal performance factor 2 (Region V) ≥ 6.0

    Off mode power consumption ≤ 33 W

    On or after January 1, 2023 and before January 1, 2025
    4Split system central heat pumps that are small-duct and high-velocity10 C.F.R. Appendix M1

    Seasonal energy efficiency ratio 2 ≥ 12.0

    Heating seasonal performance factor 2 (Region V) ≥ 4.9

    Off mode power consumption ≤ 30 W

    On or after January 1, 2023 and before January 1, 2025
    5Split system central heat pumps that are space-constrained10 C.F.R. Appendix M1

    Seasonal energy efficiency ratio 2 ≥ 11.9

    Heating seasonal performance factor 2 (Region V) ≥ 5.0

    Off mode power consumption ≤ 33 W

    On or after January 1, 2023 and before January 1, 2025
    6Split system central heat pumps, other than those that are small-duct and high-velocity or space-constrained10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F)

    Seasonal energy efficiency ratio 2 ≥ 14.3

    Heating seasonal performance factor 2 (Region V) ≥ 6.0

    Off mode power consumption ≤ 33 W

    On or after January 1, 2025
    7Split system central heat pumps that are small-duct and high-velocity10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F)

    Seasonal energy efficiency ratio 2 ≥ 12.0

    Heating seasonal performance factor 2 (Region V) ≥ 4.9

    Off mode power consumption ≤ 30 W

    On or after January 1, 2025
    8Split system central heat pumps that are space-constrained10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F)

    Seasonal energy efficiency ratio 2 ≥ 11.9

    Heating seasonal performance factor 2 (Region V) ≥ 5.0

    Off mode power consumption ≤ 33 W

    On or after January 1, 2025

    TABLE 2

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductTesting StandardEnergy Efficiency StandardPeriod of Manufacture
    1Split system central heat pumps, other than those that are small-duct and high-velocityCSA C656-14

    Seasonal energy efficiency ratio ≥ 14.0

    Heating seasonal performance factor (Region V) ≥ 7.1

    On or after December 31, 1998
    2Split system central heat pumps that are small-duct and high-velocityCSA C656-14

    Seasonal energy efficiency ratio ≥ 12.0

    Heating seasonal performance factor (Region V) ≥ 6.3

    On or after December 31, 1998
  • SOR/2019-163, s. 42
  • SOR/2022-265, s. 21

Date modified: