Government of Canada / Gouvernement du Canada
Symbol of the Government of Canada

Search

Energy Efficiency Regulations, 2016

Version of section 260 from 2019-04-30 to 2019-06-02:


Marginal note:Information

 For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas furnace described in column 1.

TABLE

Column 1Column 2Column 3
ItemEnergy-using ProductStandardInformation
1Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured before December 31, 2009CSA 2.3
  • (a) heating capacity, in kW (Btu/h); and

  • (b) annual fuel utilization efficiency.

2Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured on or after December 31, 2009 and before July 3, 2019CSA P.2
  • (a) maximum heat input and output nominal capacities, in kW (Btu/h);

  • (b) annual fuel utilization efficiency;

  • (c) information that indicates whether product has an integrated cooling component;

  • (d) if product has an integrated cooling component, information that indicates whether the product is outdoor or through-the-wall;

  • (e) standby power, in W;

  • (f) power burner’s PE and VPE; and

  • (g) type of fuel used.

2.1Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured on or after July 3, 2019

CSA P.2, for information set out in paragraphs (a) to (e)

10 C.F.R. Appendix AA, for information set out in paragraphs (f) and (g)

  • (a) maximum heat input and output nominal capacities, in kW (Btu/h);

  • (b) annual fuel utilization efficiency;

  • (c) information that indicates whether product has an integrated cooling component;

  • (d) if product has an integrated cooling component, information that indicates whether the product is outdoor or through-the-wall;

  • (e) type of fuel used;

  • (f) FER, expressed in W/472 L/s (W/1,000 ft³/min); and

  • (g) product’s maximum airflow (Qmax), expressed in L/s (ft³/min).

3Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h) and that use three-phase electric currentCSA 2.3
  • (a) heating capacity, in kW (Btu/h); and

  • (b) annual fuel utilization efficiency or thermal efficiency.

4Gas furnaces that have an input rate of > 65.92 kW (225,000 Btu/h) but ≤ 117.23 kW (400,000 Btu/h)CSA 2.3
  • (a) heating capacity, in kW (Btu/h); and

  • (b) thermal efficiency.

  • SOR/2018-201, s. 36

Date modified: