Energy Efficiency Regulations, 2016
Marginal note:Definitions
369 (1) The following definitions apply in this Division.
- CSA P.3-15
CSA P.3-15 means the CSA standard CAN/CSA-P.3-15 entitled Testing method for measuring energy consumption and determining efficiencies of gas-fired and fuel oil-fired water heaters. (CSA P.3-15)
- electric water heater
electric water heater means a stationary electric storage tank water heater that is intended for use on a pressurized water system and has a Vr of at least 50 L (13.21 US gallons). (chauffe-eau électrique)
- first-hour rating
first-hour rating means, in respect of an electric water heater, gas-fired storage water heater or oil-fired water heater, the measure of the maximum volume of hot water that the water heater can supply within an hour that begins when the water in the water heater is fully heated. (capacité de première heure)
- gas-fired instantaneous water heater
gas-fired instantaneous water heater means a flow-activated water heater that uses propane or natural gas for fuel, has a Vr that is less than or equal to 38 L (10 US gallons) and has an input rate to Vr ratio of at least 309 W/L (4,000 Btu/h/US gallon). (chauffe-eau instantané au gaz)
- gas-fired storage water heater
gas-fired storage water heater means a stationary gas-heated water container that uses propane or natural gas for fuel and has a Vr of at least 76 L (20 US gallons). (chauffe-eau à réservoir alimenté au gaz)
- oil-fired water heater
oil-fired water heater means a water heater that uses oil for fuel and has a Vr of at least 76 L (20 US gallons). (chauffe-eau à mazout)
- 10 C.F.R. Appendix A
10 C.F.R. Appendix A means Appendix A to Subpart G, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Thermal Efficiency and Standby Loss of Gas-Fired and Oil-Fired Storage Water Heaters and Storage-Type Instantaneous Water Heaters, as amended from time to time. (appendice A 10 C.F.R.)
- 10 C.F.R. Appendix E
10 C.F.R. Appendix E means Appendix E to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Water Heaters, as amended from time to time, except for sections 5.1.1 and 5.1.2. (appendice E 10 C.F.R.)
- Veff
Veff means the effective storage volume, expressed in litres, of a water heater’s storage tank, as determined in accordance with 10 C.F.R. Appendix E. (Veff)
- Vr
Vr means the nominal volume, expressed in litres, of a water heater’s storage tank. (Vr)
- Vs
Vs means the measured storage volume, expressed in litres, of a water heater’s storage tank. (Vs)
Marginal note:Interpretation — draw pattern
(2) In this Division, a reference to
(a) a “very-small-usage” draw pattern is to be read as a reference to the draw pattern set out in Table III.1 to section 5.5 of 10 C.F.R. Appendix E;
(b) a “low-usage” draw pattern is to be read as a reference to the draw pattern set out in Table III.2 to section 5.5 of 10 C.F.R. Appendix E;
(c) a “medium-usage” draw pattern is to be read as a reference to the draw pattern set out in Table III.3 to section 5.5 of 10 C.F.R. Appendix E; and
(d) a “high-usage” draw pattern is to be read as a reference to the draw pattern set out in Table III.4 to section 5.5 of 10 C.F.R. Appendix E.
- SOR/2018-201, s. 38
- SOR/2019-164, s. 24
- SOR/2025-110, s. 45