Energy Efficiency Regulations, 2016

Version of section 380 from 2018-10-31 to 2019-12-11:


Marginal note:Energy efficiency standards

  •  (1) The energy efficiency standards set out in column 3 of the table to this section apply to oil-fired water heaters described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard

    (2) An oil-fired water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to an oil-fired water heater as defined in section 378.

    TABLE

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductStandardEnergy Efficiency StandardPeriod of Manufacture
    1Oil-fired water heatersCSA B211-00Energy factor of ≥ 0.59 – 0.0005 VrOn or after February 3, 1995 and before December 31, 2016
    2Oil-fired water heatersCSA B211-00Energy factor of ≥ 0.68 – 0.0005 VrOn or after December 31, 2016 and before January 1, 2018
    3Oil-fired water heaters that have a first-hour rating of < 68 L (18 US gallons)

    CSA B211-00 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.68 – 0.0005 Vr; or

    • (b) uniform energy factor of ≥ 0.2509 – 0.00032 Vs.

    On or after January 1, 2018
    4Oil-fired water heaters that have a first-hour rating of ≥ 68 L (18 US gallons) but < 193 L (51 US gallons)

    CSA B211-00 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.68 – 0.0005 Vr; or

    • (b) uniform energy factor of ≥ 0.5330 – 0.00042 Vs.

    On or after January 1, 2018
    5Oil-fired water heaters that have a first-hour rating of ≥ 193 L (51 US gallons) but < 284 L (75 US gallons)

    CSA B211-00 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.68 – 0.0005 Vr; or

    • (b) uniform energy factor of ≥ 0.6078 – 0.00042 Vs.

    On or after January 1, 2018
    6Oil-fired water heaters that have a first-hour rating of > 284 L (75 US gallons)

    CSA B211-00 for energy factor

    CSA P.3-15 for uniform energy factor

    Must have at least one of the following:

    • (a) energy factor of ≥ 0.68 – 0.0005 Vr; or

    • (b) uniform energy factor of ≥ 0.6815 – 0.00037 Vs.

    On or after January 1, 2018
  • SOR/2018-201, s. 41