Energy Efficiency Regulations, 2016

Version of section 641 from 2016-12-09 to 2017-06-27:

The following provision is not in force.

Marginal note:Energy efficiency standards

  •  (1) The energy efficiency standards set out in column 2 of the table to this section apply to commercial refrigerator-freezers described in column 1 that are manufactured during the periods set out in column 3.

  • Marginal note:Testing standard

    (2) A commercial refrigerator-freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C657, Test Procedure A, that are applicable to a commercial refrigerator-freezer as defined in section 636.

    TABLE

    Column 1Column 2Column 3
    ItemEnergy-using ProductEnergy Efficiency StandardPeriod of Manufacture
    1Commercial refrigerator-freezers that are closed and not transparentEdaily ≤ 0.00964 AV + 2.63On or after April 1, 2007 and before January 1, 2008
    2Commercial refrigerator-freezers that are closed and not transparentEdaily ≤ 0.00964 AV + 1.65On or after January 1, 2008 and before January 1, 2010
    3Commercial refrigerator-freezers that are closed and not transparentEdaily ≤ the greater of (0.00953 AV – 0.71) and 0.70On or after January 1, 2010
    4Commercial refrigerator-freezers that are open or transparentCSA C657, Table 5On or after January 1, 2012