  •  (1) A weighing device shall perform within the applicable limits of error when exposed

    • (a) where a temperature range is marked on the device, within that temperature range; and

    • (b) where no temperature range is marked on the device, at any temperature of at least -10°C and no more than 40°C.

  • (2) The minimum marked temperature range on a weighing device shall be

    • (a) in the case of Class Oval outline with the text I inside devices, 5°C;

    • (b) in the case of Class Oval outline with the text II inside devices, 15°C; and

    • (c) in the case of Class Oval outline with the text III inside, Oval outline with the text IIIHD inside and Oval outline with the text IIII inside devices, 30°C.