Specifications Relating to Non-automatic Weighing Devices (1998) (SI/98-81)
Full Document:
- HTMLFull Document: Specifications Relating to Non-automatic Weighing Devices (1998) (Accessibility Buttons available) |
- XMLFull Document: Specifications Relating to Non-automatic Weighing Devices (1998) [113 KB] |
- PDFFull Document: Specifications Relating to Non-automatic Weighing Devices (1998) [356 KB]
Regulations are current to 2026-09-30 and last amended on 2019-06-17. Previous Versions
63 (1) Approach and exit ramps to and from a permanently installed vehicle scale shall
(a) be straight for a distance of at least 3 m adjacent to the weighbridge;
(b) be as wide as, and in the same plane as, the weighbridge;
(c) be constructed, for a distance of at least 3 m adjacent to the weighbridge, of concrete or similar durable material to ensure that they remain smooth, level and in the same plane as the weighbridge; and
(d) beyond the 3 m distance set out in paragraphs (a) and (c), be constructed so as to permit
(i) easy access by the vehicle being weighed,
(ii) ready access for testing purposes, and
(iii) any water to drain away from the scale.
(2) Where approach and exit ramps to and from a permanently installed vehicle scale include grating, the grating shall be of sufficient strength to withstand all loads that are intended to be supported by the scale.
Page Details
- Date modified: