Electricity and Gas Inspection Regulations (SOR/86-131)

Regulations are current to 2017-12-11 and last amended on 2014-08-01. Previous Versions

 An inspector shall not, in the execution of his functions, use any measuring apparatus other than a measuring apparatus permitted by section 5 of the Act.

PART VIIIProvisions Specific to Gas

Prohibited Substances

 No person shall supply to a purchaser for any purpose other than processing or delivery for processing, natural gas that contains more than 0.030 per cent of water vapour, calculated by volume at standard pressure and standard temperature.

Sale of Gas by Volume

 A volume of gas measured by any meter that registers in units of volume shall be converted to standard volume by using the following equation, namely,

Vs = Vr × Pm × Tm × (Fpv)2

where

  • (a) Vs is the standard volume;

  • (b) Vr is the volume registered by the meter;

  • (c) Pm is the pressure multiplier established for the meter pursuant to section 36;

  • (d) Tm is the temperature multiplier established for the meter pursuant to section 38 or 39, whichever is applicable; and

  • (e) Fpv is the supercompressibility factor established for the meter pursuant to section 40.

  • SOR/95-532, s. 3(F).

Pressure Multiplier

  •  (1) The pressure multiplier for any pressure converting meter shall be established by using the following equation, namely,

    Pm = Pb/Ps

    where

    • (a) Pm is the pressure multiplier;

    • (b) Pb is the pressure expressed on the absolute pressure scale and used as the base pressure for the calibration of the pressure converting meter; and

    • (c) Ps is the standard pressure expressed on the absolute pressure scale.

  • (2) The pressure multiplier for any meter other than a pressure correcting meter shall be established by using the following equation, namely,

    Pm = (Pga + Pa)/Ps

    where

    • (a) Pm is the pressure multiplier;

    • (b) Pga is the average meter pressure expressed on the gauge pressure scale;

    • (c) Pa is

      • (i) the mean atmospheric pressure at the meter location, expressed to at least four significant digits,

      • (ii) the atmospheric pressure calculated for the meter location pursuant to subsection 37(1), expressed to at least four significant digits,

      • (iii) the atmospheric pressure declared for the meter location pursuant to subsection 37(2), expressed to at least four significant digits, or

      • (iv) the measured atmospheric pressure at the meter location, expressed to at least four significant digits; and

    • (d) Ps is the standard pressure expressed on the absolute pressure scale.

  • SOR/95-532, s. 3.

Atmospheric Pressure

  •  (1) The atmospheric pressure shall be calculated for a meter location by using the following equation, namely,

    • (a) in the International system of units,

      Pa = 101.560 - (0.0113 × M) kPa, or

    • (b) in the Imperial system of units,

      Pa = 14.73 - (0.0005 × F) psia

      where

    • (c) Pa is the calculated atmospheric pressure; and

    • (d) M is the number of metres of elevation of the meter location above mean sea level and F is the number of feet of elevation of the meter location above mean sea level, in either case as determined by a survey carried out by a registered surveyor or as determined from the most recent applicable topographical maps published by the Department of Energy, Mines and Resources.

  • (2) The atmospheric pressure declared for a meter location shall not differ from the atmospheric pressure calculated for that meter location pursuant to subsection (1) by more than

    • (a) in the International system of units,

      0.621 + (0.001 × Pga) kPa, or

    • (b) in the Imperial system of units,

      0.090 + (0.001 × Pga) psi

      where

      Pga
      is the average meter pressure expressed on the gauge pressure scale.

Temperature Multiplier

  •  (1) Subject to section 39, the temperature multiplier for any temperature converting meter shall be established by using the following equation, namely,

    • (a) in the International system of units,

      Tm = 288.15/(Tb + 273.15), or

    • (b) in the Imperial system of units,

      Tm = 519.67/(Tb + 459.67)

      where

    • (c) Tm is the temperature multiplier; and

    • (d) Tb is the temperature established by the contractor and used as the base temperature for the calibration of the temperature converting meter.

  • (2) Subject to section 39, the temperature multiplier of any meter other than a temperature converting meter shall be established by using the following equation, namely,

    • (a) in the International system of units,

      Tm = 288.15/(Tga + 273.15), or

    • (b) in the Imperial system of units,

      Tm = 519.67/(Tga + 459.67)

      where

    • (c) Tm is the temperature multiplier; and

    • (d) Tga is the average flowing gas temperature.

  • SOR/95-532, s. 3.

 A temperature multiplier of one may be used for

  • (a) meters that are purchased prior to December 31, 1986 and

    • (i) that have a capacity that is less than 14 standard cubic metres per hour at a differential pressure of 0.125 kPa, or

    • (ii) that have a capacity that is less than 500 standard cubic feet per hour at a differential pressure of 0.5 in. of water column;

  • (b) meters that are installed prior to December 31, 1986, where the average meter pressure exceeds the atmospheric pressure by more than 3.5 kPa in the International system of units or 0.5 psi in the Imperial system of units; and

  • (c) meters that are installed where the average meter pressure does not exceed the atmospheric pressure by more than 3.5 kPa in the International system of units or 0.5 psi in the Imperial system of units and that

    • (i) were most recently sealed prior to December 31, 1986, and

    • (ii) have a capacity that is greater than that stated in subparagraph (a)(i) or (ii), whichever is applicable.

Supercompressibility Factor

 For the purpose of paragraph 35(e),

  • (a) subject to paragraphs (b) and (c), the supercompressibility factor for any meter shall be established based on

    • (i) the pressure exerted by the gas within the meter and the temperature of the gas flowing through the meter as determined by continuous monitoring at the meter location,

    • (ii) the relative density, the carbon dioxide content and the nitrogen content of the gas being measured, as determined by

      • (A) a gas sampling process, if the process gives results that are representative of the gas at the meter location, or

      • (B) continuous monitoring at the meter location, and

    • (iii) if the parameters of the gas referred to in subparagraphs (i) and (ii) vary, either the time weighted or the volume weighted averages of those parameters during the period that the volume of the gas is measured by the meter;

  • (b) the supercompressibility factor for any meter for which the pressure exerted by the gas within the meter expressed on the gauge pressure scale does not exceed 207 kPa in the International system of units, or 30 psi in the Imperial system of units, may be established based on

    • (i) the pressure exerted by the gas within the meter, established and maintained through the use of a pressure factor metering regulator that has been approved and verified under section 9 of the Act,

    • (ii) an assumed flowing gas temperature of 59°F or 15°C, and

    • (iii) the relative density, the carbon dioxide content and the nitrogen content of the gas being measured as determined by a gas sampling process, if the process gives results that are representative of the gas at the meter location; or

  • (c) a supercompressibility factor of one may be used if the pressure exerted by the gas within the meter expressed on the gauge pressure scale does not exceed 700 kPa in the International system of units or 100 psi in the Imperial system of units.

  • SOR/2006-76, s. 2.
 