Electricity and Gas Inspection Regulations (SOR/86-131)

Regulations are current to 2026-06-21 and last amended on 2018-11-23. Previous Versions

  •  (1) Subject to section 39, the temperature multiplier for any temperature converting meter shall be established by using the following equation, namely,

    • (a) in the International system of units,

      Tm = 288.15/(Tb + 273.15), or

    • (b) in the Imperial system of units,

      Tm = 519.67/(Tb + 459.67)

      where

    • (c) Tm is the temperature multiplier; and

    • (d) Tb is the temperature established by the contractor and used as the base temperature for the calibration of the temperature converting meter.

  • (2) Subject to section 39, the temperature multiplier of any meter other than a temperature converting meter shall be established by using the following equation, namely,

    • (a) in the International system of units,

      Tm = 288.15/(Tga + 273.15), or

    • (b) in the Imperial system of units,

      Tm = 519.67/(Tga + 459.67)

      where

    • (c) Tm is the temperature multiplier; and

    • (d) Tga is the average flowing gas temperature.

  • SOR/95-532, s. 3