  1. Canada–Newfoundland and Labrador Offshore Area Petroleum Operations Framework Regulations - SOR/2024-25 (Section 135)

    [...]

    Marginal note:Boilers and pressure systems
    • [...]

    • [...]

      (2) The boilers and pressure systems must be designed to

      • [...]

      • [...]

        (g) monitor safe limits of pressure, temperature and fluid levels and reliably protect against exceeding those limits;

    • [...]

      (3) The design of boilers and pressure systems must

      • [...]

        (a) be based on standards that incorporate safety margins, that conform to good engineering practice and that involve the carrying out of analyses and numerical modelling as necessary to determine the behaviour and failure modes of the boilers and pressure systems under all foreseeable operating conditions, taking into account

        • [...]

        • (ii) ambient and operating temperatures,

      • [...]

        (b) if hazards cannot be eliminated, incorporate safety measures that take into account

        • [...]

        • (iii) the surface temperature of the boilers and pressure systems, and

    • [...]

      Marginal note:Loads and other factors

      (4) The operator must ensure that boilers and pressure systems can withstand all combinations of loads, pressures, temperatures, fluids and substances to which they may be subjected during their design service life.

    • [...]

    • [...]

      (12) The operator must keep a register of all boilers and pressure systems that includes the following documents and information in respect of each:

      • [...]

      • [...]

        (c) the boiler or pressure system’s operating limits, including its pressure and temperature ratings;

      • [...]

      • [...]

        (e) in respect of each inspection and test referred to in subsection (7) or (8), a record created and signed by the authorized inspector who conducted the inspection that includes

        • [...]

        • (iii) the range of safe pressure and temperature at which the boiler or pressure system may be operated,


  2. Canada–Newfoundland and Labrador Offshore Area Petroleum Operations Framework Regulations - SOR/2024-25 (Section 136)

    [...]

    Marginal note:Mechanical equipment
    • [...]

    • [...]

      (2) Mechanical equipment must be designed to eliminate hazards to safety or the environment in the following scenarios or, if that is not possible, to mitigate the risks posed by those hazards:

      • [...]

      • [...]

        (c) extreme surface temperatures of the mechanical equipment;

    • [...]

    • [...]

      (5) The operator must ensure that turbines and internal combustion engines are

      • [...]

      • [...]

        (c) equipped with safety devices — including manual fuel shut-off devices and, unless it would increase safety or environmental risks, automatic fuel shut-off devices — to prevent major damage from overspeeding, high exhaust temperature, high cooling water temperature, low lubricating oil pressure or other foreseeable hazards that could impair the safety of operations.


  3. Canada–Newfoundland and Labrador Offshore Area Petroleum Operations Framework Regulations - SOR/2024-25 (Section 112)

    [...]

    Marginal note:Passive fire and blast protection
    • [...]

    • [...]

      Marginal note:Bulkheads — production installation

      (9) Unless the other combined features of a production installation can be demonstrated to provide at least the same level of protection, the operator must ensure that the following bulkheads are capable of preventing the passage of smoke and flame and of limiting the temperature rise on the unexposed face of the bulkhead to an average increase of 139°C and a maximum increase of 180°C above the initial temperature following 120 minutes of exposure to a hydrocarbon fire:

      [...]


  4. Canada–Newfoundland and Labrador Offshore Area Petroleum Operations Framework Regulations - SOR/2024-25 (Section 193)

    [...]

    Marginal note:Critical information
    • [...]

       (1) The records that must be kept under section 181 include, in the case of an operation involving drilling or production, records containing the following information and documents:

      • [...]

      • [...]

        (c) the pressure, temperature and flow rate data obtained from compressors and from systems and equipment used for treatment and processing;


  5. Canada–Newfoundland and Labrador Offshore Area Petroleum Operations Framework Regulations - SOR/2024-25 (Section 123)

    [...]

    Marginal note:Control system
    • [...]

    • [...]

      Marginal note:Protection of hardware

      (3) The operator must ensure that control system hardware is protected from circumstances, including excessive vibration, high electromagnetic field levels, electrical power disturbances and extreme temperatures or humidity levels or other physical and environmental conditions, that could cause mechanical damage to or degradation of the hardware or that could otherwise adversely affect the performance of the system.