  1. Nova Scotia Offshore Petroleum Installations Regulations - SOR/95-191 (Section 8)
    •  (1) In this section

      process vessel

      process vessel means a heater, dehydrator, separator, treater or vessel used in the processing or treatment of produced gas or oil. (récipient de fabrication)

    • (2) No person shall create or cause to be created any unprotected flame or source of ignition within 50 m of a well, an oil storage tank or other source of ignitable vapour.

    • (3) No flame-type equipment shall be placed or operated within 25 m of a well, an oil storage tank or other source of ignitable vapour, except

      [...]

    • [...]

    • (7) An exhaust pipe from an internal combustion engine located within 25 m of a well, a process vessel, an oil storage tank or other source of ignitable vapour shall be constructed so that

      [...]

    • (8) All equipment at or near a well, a process vessel, an oil storage tank or other source of ignitable vapour shall be constructed in accordance with Part I of the Canadian Electrical Code Part I and the Oil and Gas Occupational Health and Safety Regulations.


  2. Nova Scotia Offshore Petroleum Installations Regulations - SOR/95-191 (Section 23)
    • [...]

    • (2) Subject to subsection (3), on an installation,

      • [...]

      • (d) every machinery space and every storeroom containing paint, oil, any gaseous substance or other flammable material shall be separated from galleys or accommodation areas by class A-60 divisions and from each other by class A-0 divisions;

      • [...]

      • (o) for compartments that contain or are affected by oil and oil vapour, the surface of insulating materials fitted to the inside of bulkheads and decks and forming the casings and crowns shall be impervious to oil and oil vapour;


  3. Nova Scotia Offshore Petroleum Installations Regulations - SOR/95-191 (Section 57)
    • [...]

    • (7) Where crude oil is to be stored in a floating platform, the platform shall have enough ballast capacity, segregated from the crude storage, to be able to float at minimum operating draft with no crude oil on board.

    • [...]

    • (12) Every floating platform shall be equipped with a bilge system that has at least two bilge pumps connected to the bilge main and that is capable, under all conditions from upright to 15 degrees in any direction, of pumping or draining any watertight compartment except for those spaces permanently designated for the storage of fresh water, water ballast, fuel oil or liquid cargo and for which other effective means of pumping are provided.


  4. Nova Scotia Offshore Petroleum Installations Regulations - SOR/95-191 (Section 35)
    • [...]

    • (2) Every pressure vessel or fired vessel on a production installation shall be designed and constructed in accordance with the following standards:

      • (a) American Petroleum Institute Spec 12J, Specification for Oil and Gas Separators;

    • [...]

    • (4) All materials and procedures used in a production installation used to produce and process sour gas shall conform to National Association of Corrosion Engineers (U.S.) MR-01-75, Sulfide Stress Cracking Resistant Metallic Materials for Oil Field Equipment.

    • (5) Where an operator handles, treats or processes oil, gas or water that contains hydrogen sulphide, the operator shall do so in accordance with good industry practice to minimize the discharge of hydrogen sulphide into the environment and to ensure that the operation is carried out in a safe and efficient manner.


  5. Nova Scotia Offshore Petroleum Installations Regulations - SOR/95-191 (Section 29)
    • [...]

    • (3) Each extinguisher provided pursuant to subsection (1) for use in machinery spaces where oil is used as fuel shall be of a type discharging foam, carbon dioxide gas or dry powder.

    • [...]

    • (7) On an installation, every space containing an oil- or gas-fired boiler or any other fired process vessel that has a thermal rating of at least 75 kW shall be provided with

      [...]

    • (8) Every portable foam applicator unit provided pursuant to this section shall be provided with

      • (a) an air-foam nozzle of an inductor type capable of being connected to the water main described in subsection 24(2) and of producing foam effective for extinguishing an oil fire at the rate of at least 1.5 m3/minute; and



Date modified: