147 (1) Every bulkhead and deck that separates a cargo pump room, cargo pump room entrance or machinery space of Category A from an accommodation space, service space or control station shall be an ‘A-60’ Class division.
(2) The following exterior boundaries of a superstructure or deckhouse that encloses an accommodation space or service space shall be insulated to the same standards applicable in respect of an ‘A-60’ Class division:
(a) the whole of the boundary facing the cargo tanks;
(b) the sides within 3 m of the boundary facing the cargo tanks; and
(c) where the deck of the superstructure or deckhouse overhangs the main deck, the portion of the overhanging deck that is within 3 m of the boundary referred to in paragraph (a).
(3) [Revoked, SOR/90-240, s. 5]
- SOR/78-605, s. 3
- SOR/83-521, s. 4
- SOR/90-240, s. 5