Energy Efficiency Regulations, 2016
Marginal note:Energy efficiency standards
447 (1) The energy efficiency standards set out in column 3 of the table to this section apply to general service fluorescent lamps described in column 1 that are manufactured during the periods set out in column 4.
Marginal note:Testing standard
(2) A general service fluorescent lamp complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a general service fluorescent lamp as defined in section 445.
Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Standard Energy Efficiency Standard Period of Manufacture 1 General service fluorescent lamps that are rapid-start and straight-shaped and that have a nominal overall length of 1 200 mm, a medium bi-pin base and a nominal power of > 35 W CSA C819-95 Average lamp efficacy ≥ 75 lm/W
Average colour rendering index ≥ 69
Before July 15, 2012 2 General service fluorescent lamps that are rapid-start and straight-shaped and that have a nominal overall length of 1 200 mm, a medium bi-pin base and a nominal power of ≤ 35 W CSA C819-95 Average lamp efficacy ≥ 75 lm/W
Average colour rendering index ≥ 45
Before July 15, 2012 3 General service fluorescent lamps that are rapid-start and straight-shaped and that have a nominal overall length of 2 400 mm, a recessed double-contact base, a nominal power of > 100 W and a nominal current of 0.8 A CSA C819-95 Average lamp efficacy ≥ 80 lm/W
Average colour rendering index ≥ 69
Before July 15, 2012 4 General service fluorescent lamps that are rapid-start and straight-shaped and that have a nominal overall length of 2 400 mm, a recessed double-contact base, a nominal power of ≤ 100 W and a nominal current of 0.8 A CSA C819-95 Average lamp efficacy ≥ 80 lm/W
Average colour rendering index ≥ 45
Before July 15, 2012 5 General service fluorescent lamps that are rapid-start and U-shaped and that have a nominal overall length of ≥ 560 mm but ≤ 635 mm, a medium bi-pin base and a nominal power of > 35 W CSA C819-95 Average lamp efficacy ≥ 68 lm/W
Average colour rendering index ≥ 69
Before July 15, 2012 6 General service fluorescent lamps that are rapid-start and U-shaped and that have a nominal overall length of ≥ 560 mm but ≤ 635 mm, a medium bi-pin base and a nominal power of ≤ 35 W CSA C819-95 Average lamp efficacy ≥ 64 lm/W
Average colour rendering index ≥ 45
Before July 15, 2012 7 General service fluorescent lamps that are instant-start and straight-shaped and that have a nominal overall length of 2 400 mm, a single-pin base and a nominal power of > 65 W CSA C819-95 Average lamp efficacy ≥ 80 lm/W
Average colour rendering index ≥ 69
Before July 15, 2012 8 General service fluorescent lamps that are instant-start and straight-shaped and that have a nominal overall length of 2 400 mm, a single-pin base and a nominal power of ≤ 65 W CSA C819-95 Average lamp efficacy ≥ 80 lm/W
Average colour rendering index ≥ 45
Before July 15, 2012 9 General service fluorescent lamps CSA C819-11 CSA C819-11, Table 1 On or after July 15, 2012 and before January 26, 2018 10 General service fluorescent lamps CSA C819-16 or 10 C.F.R. Appendix R CSA C819-16, Table 1 or average lamp efficacy × 1.011 > the minimum average lamp efficacy for the product in 10 C.F.R. §430.32(n)(4) On or after January 26, 2018
- Date modified: