Government of Canada / Gouvernement du Canada
Symbol of the Government of Canada

Search

Energy Efficiency Regulations, 2016

Version of section 447 from 2017-06-28 to 2019-04-29:


Marginal note:Energy efficiency standards

  •  (1) The energy efficiency standards set out in column 3 of the table to this section apply to general service fluorescent lamps described in column 1 that are manufactured during the periods set out in column 4.

  • Marginal note:Testing standard

    (2) A general service fluorescent lamp complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a general service fluorescent lamp as defined in section 445.

    TABLE

    Column 1Column 2Column 3Column 4
    ItemEnergy-using ProductStandardEnergy Efficiency StandardPeriod of Manufacture
    1General service fluorescent lamps that are rapid-start and straight-shaped and that have a nominal overall length of 1 200 mm, a medium bi-pin base and a nominal power of > 35 WCSA C819-95

    Average lamp efficacy ≥ 75 lm/W

    Average colour rendering index ≥ 69

    Before July 15, 2012
    2General service fluorescent lamps that are rapid-start and straight-shaped and that have a nominal overall length of 1 200 mm, a medium bi-pin base and a nominal power of ≤ 35 WCSA C819-95

    Average lamp efficacy ≥ 75 lm/W

    Average colour rendering index ≥ 45

    Before July 15, 2012
    3General service fluorescent lamps that are rapid-start and straight-shaped and that have a nominal overall length of 2 400 mm, a recessed double-contact base, a nominal power of > 100 W and a nominal current of 0.8 ACSA C819-95

    Average lamp efficacy ≥ 80 lm/W

    Average colour rendering index ≥ 69

    Before July 15, 2012
    4General service fluorescent lamps that are rapid-start and straight-shaped and that have a nominal overall length of 2 400 mm, a recessed double-contact base, a nominal power of ≤ 100 W and a nominal current of 0.8 ACSA C819-95

    Average lamp efficacy ≥ 80 lm/W

    Average colour rendering index ≥ 45

    Before July 15, 2012
    5General service fluorescent lamps that are rapid-start and U-shaped and that have a nominal overall length of ≥ 560 mm but ≤ 635 mm, a medium bi-pin base and a nominal power of > 35 WCSA C819-95

    Average lamp efficacy ≥ 68 lm/W

    Average colour rendering index ≥ 69

    Before July 15, 2012
    6General service fluorescent lamps that are rapid-start and U-shaped and that have a nominal overall length of ≥ 560 mm but ≤ 635 mm, a medium bi-pin base and a nominal power of ≤ 35 WCSA C819-95

    Average lamp efficacy ≥ 64 lm/W

    Average colour rendering index ≥ 45

    Before July 15, 2012
    7General service fluorescent lamps that are instant-start and straight-shaped and that have a nominal overall length of 2 400 mm, a single-pin base and a nominal power of > 65 WCSA C819-95

    Average lamp efficacy ≥ 80 lm/W

    Average colour rendering index ≥ 69

    Before July 15, 2012
    8General service fluorescent lamps that are instant-start and straight-shaped and that have a nominal overall length of 2 400 mm, a single-pin base and a nominal power of ≤ 65 WCSA C819-95

    Average lamp efficacy ≥ 80 lm/W

    Average colour rendering index ≥ 45

    Before July 15, 2012
    9General service fluorescent lampsCSA C819-11CSA C819-11, Table 1On or after July 15, 2012 and before January 26, 2018
    10General service fluorescent lampsCSA C819-16 or 10 C.F.R. Appendix RCSA C819-16, Table 1 or average lamp efficacy × 1.011 > the minimum average lamp efficacy for the product in 10 C.F.R. §430.32(n)(4)On or after January 26, 2018

Date modified: