Pacifiers Regulations (SOR/2016-184)
Full Document:
- HTMLFull Document: Pacifiers Regulations (Accessibility Buttons available) |
- XMLFull Document: Pacifiers Regulations [12 KB] |
- PDFFull Document: Pacifiers Regulations [343 KB]
Regulations are current to 2024-10-30
SCHEDULE 2(Paragraph 5(b))Structural Integrity Test
1 The following method is to be used for testing the structural integrity of the pacifier:
(a) hold the nipple of the pacifier in a fixed position and apply to the ring or handle of the pacifier a force of 44.5 ± 1.0 N in the plane of the axis of the nipple at a rate of 4.5 ± 1.0 N/s and then maintain the final force for 10 ± 0.5 s;
(b) hold the guard of the pacifier in a fixed position and apply to the ring or handle of the pacifier a force of 44.5 ± 1.0 N in the plane perpendicular to the axis of the nipple at a rate of 4.5 ± 1.0 N/s and then maintain the final force for 10 ± 0.5 s;
(c) repeat the procedure described in paragraph (b) with the force applied to the nipple of the pacifier;
(d) immerse the pacifier in boiling water for 10 ± 0.5 min, then remove the pacifier from the boiling water and allow to cool in air at 21 ± 5° C for 15 ± 0.5 min;
(e) repeat the procedures described in paragraphs (a) to (c); and
(f) repeat the procedures described in paragraphs (d) and (e) nine times.
- Date modified: