Energy Efficiency Regulations, 2016
Marginal note:Information
756 (1) For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a small electric motor:
(a) its average full load efficiency;
(b) its type, namely, capacitor-start capacitor-run, capacitor-start induction-run or polyphase; and
(c) if the motor is one for which a unique motor identifier has not been provided under paragraph 5(1)(c), its nominal output power expressed in kilowatts (horsepower) and the number of poles.
Marginal note:Standard
(2) The information must be collected in accordance with one of the following standards:
(a) if the motor is polyphase and has a nominal output power ≥ 0.18 kW (0.25 horsepower) but ≤ 0.75 kW (1 horsepower), CSA C747-09 or IEEE 112-2004, Test Method A;
(b) if the motor is polyphase and has a nominal output power > 0.75 kW (1 horsepower) but ≤ 2.2 kW (3 horsepower), CSA C390-10 or IEEE 112-2004, Test Method B; or
(c) if the motor is capacitor-start capacitor-run or capacitor-start induction-run, CSA C747-09 or IEEE 114-2010.
- SOR/2018-201, s. 80