Language selection

Government of Canada

Search

Hull Construction Regulations (C.R.C., c. 1431)

Regulations are current to 2026-03-17 and last amended on 2023-12-20. Previous Versions

  •  (1) Every interior crew access opening that gives direct access to a space below the main deck from inside a wheelhouse shall be fitted with a type ‘A’ closing appliance.

  • (2) Subject to subsection (3), every interior crew access opening that gives direct access to a space below the main deck, other than an opening described in subsection (1), shall be fitted with a closing appliance that

    • (a) in association with the reinforcing of the opening is of equivalent strength to the unpierced structure in which it is set;

    • (b) is close fitting and supported around the perimeter against external pressure;

    • (c) if hinged, opens outwards from the space below the main deck;

    • (d) if it gives access to the engine room, is self-closing and is provided with a fire protective sheathing on the engine room side; and

    • (e) if it gives access from an accommodation space to the engine room, is gastight.

  • (3) An interior crew access opening that gives direct access to a watertight accommodation space below the main deck is not required to be fitted with a closing appliance where

    • (a) the opening is located inside a structure in which every exterior crew access opening is fitted with a type ‘A’ closing appliance; and

    • (b) no part of the main deck is submerged when that accommodation space is completely flooded.

  • (4) Every interior door that gives access to an accommodation space and that is not required by these Regulations to be fitted with a type ‘A’ closing appliance, a type ‘B’ closing appliance or a closing appliance described in subsection (2) shall be fitted with a kick-out panel in the lower half of the door.

Page Details

Date modified: