Language selection

Government of Canada

Search

Accessible Transportation for Persons with Disabilities Regulations (SOR/2019-244)

Regulations are current to 2026-03-17 and last amended on 2022-06-25. Previous Versions

Marginal note:Stairs

  •  (1) Any stairs that are used to board or disembark from a ferry, and any interior stairs on a ferry, must

    • (a) meet the requirements set out in clauses 5.4.1 and 5.4.2 of CSA B651-18;

    • (b) have handrails that

      • (i) are located on both sides of the stairs,

      • (ii) are located at a uniform height of 860 mm to 920 mm, measured vertically from the leading edge of the tread, and

      • (iii) meet the requirements set out in clause 5.3.1 of CSA B651-18; and

    • (c) have tactile attention indicator surfaces that

      • (i) meet the requirements set out in clauses 4.3.5.2(a) and (b), 4.3.5.3.1 and 4.3.5.3.4 of CSA B651-18,

      • (ii) are located at the top of the stairs, and

      • (iii) commence one tread length before the top of the stairs, extend the full width of the stairs and measure from 600 mm to 650 mm in length.

  • Marginal note:Delayed application — portable stairs

    (2) For a period of two years beginning on the day on which this section comes into force, subsection (1) does not apply in respect of stairs that are portable and not integrated with the ferry.

Page Details