Cargo, Fumigation and Tackle Regulations (SOR/2007-128)
Full Document:
- HTMLFull Document: Cargo, Fumigation and Tackle Regulations (Accessibility Buttons available) |
- XMLFull Document: Cargo, Fumigation and Tackle Regulations [429 KB] |
- PDFFull Document: Cargo, Fumigation and Tackle Regulations [989 KB]
Regulations are current to 2026-03-17 and last amended on 2021-10-31. Previous Versions
358 (1) Lifting appliances shall have an emergency stop button at the operator’s position.
(2) A lifting appliance’s machinery shall have a means for promptly cutting off its power in the event of an emergency.
(3) A category 2 lifting appliance shall have
(a) an adjustable automatic slow-down device on the lowering function; and
(b) an indicator specifying the overrun to be expected under normal working conditions.
(4) If wind speed is a limiting condition for the use of a lifting appliance, the appliance shall have an anemometer that
(a) is located on a part of the appliance that is exposed to the wind; and
(b) has a read-out in the operator’s cab or, in the case of a self-unloading vessel, on the bridge or in the control room of the vessel.