Vessel Fire Safety Regulations (SOR/2017-14)
Full Document:
- HTMLFull Document: Vessel Fire Safety Regulations (Accessibility Buttons available) |
- XMLFull Document: Vessel Fire Safety Regulations [303 KB] |
- PDFFull Document: Vessel Fire Safety Regulations [764 KB]
Regulations are current to 2026-03-17 and last amended on 2022-11-23. Previous Versions
224 (1) The exposed surfaces within accommodation spaces, service spaces, control stations or corridor or stairway enclosures, and the concealed surfaces behind bulkheads, ceilings, panelling or linings in accommodation spaces, service spaces or control stations, must meet the flame spread, smoke and toxicity requirements set out in Annex 1 to the FTP Code.
(2) The exposed surfaces of glass-reinforced plastic within accommodation spaces, service spaces, control stations, machinery spaces of category A or other machinery spaces of similar fire risk to machinery spaces of category A must
(a) be coated with a final layer of fire retardant resin;
(b) be coated with a fire retardant coating; or
(c) be protected by non-combustible materials that meet the requirements for non-combustible materials set out in Annex 1 to the FTP Code.
(3) The paints, varnishes and other finishes used on any exposed interior surface must be a fire retardant coating.
Page Details