Weights and Measures Regulations (C.R.C., c. 1605)

Regulations are current to 2020-07-15 and last amended on 2019-06-17. Previous Versions

PART VSpecifications Relating to Devices (continued)

DIVISION XIVolumetric Liquid Meters (continued)

Performance (continued)

[SOR/2005-297, s. 42(F)]
  •  (1) Subject to subsections (4) and (5), the limits of error set out in the tables to subsections (2) and (3) apply to all positive displacement bulk volumetric liquid meters, including vehicle-mounted meters, that are designed to measure volumes of 180 litres or more, or 40 gallons or more, of refined petroleum products such as gasoline and fuel oils, foodstuffs such as milk, liquid fertilizers of the solution type such as aqua ammonia, or other liquids of low viscosity.

  • (2) The limits of error set out in the following table apply to meters, generally of a size 65 mm or 2½ inches or smaller that are designed to measure liquids of low viscosity:

    TABLE

    Column IColumn IIColumn III
    ItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of Error
    1Any volume of 225 litres or more up to 900 litres or of 50 gallons or more up to 200 gallons3/16% of known test quantity¼% of known test quantity
  • (3) The limits of error set out in the following table apply to meters, generally of a size 75 mm or three inches or larger that are designed to measure liquids of low viscosity:

    TABLE

    Column IColumn IIColumn III
    ItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of Error
    1Any volume of 1 350 litres or more or of 300 gallons or more1/8% of known test quantity¼% of known test quantity
  • (4) The acceptance limits of error and in-service limits of error set out in the tables to subsections (2) and (3) apply to known test quantities equal to or greater than that delivered by the meter in one minute at the maximum operating rate.

  • (5) The acceptance limits of error set out in Column II of the tables to subsections (2) and (3) apply only to tests made under controlled conditions such as bench tests and, for tests for acceptance limits of error under other conditions, the limits of error set out in Column III of those tables shall apply.

  • SOR/89-570, s. 6(F)
  • SOR/2017-17, s. 16
  • SOR/2018-252, s. 5
  •  (1) Subject to subsections (4) and (5), the limits of error set out in the tables to subsections (2) and (3) apply to all positive displacement bulk volumetric liquid meters, including vehicle-mounted meters, that are designed to measure volumes of 180 litres or more or 40 gallons or more of heavy petroleum products, such as bunker oils, foodstuffs such as syrups, liquid cattle feed, fertilizers of high specific gravities or other liquids of high viscosity.

  • (2) The limits of error set out in the following table apply to meters, generally of a size 65 mm or 2½ inches or smaller, that are used to measure liquids of high viscosity:

    TABLE

    Column IColumn IIColumn III
    ItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of Error
    1Any volume of 225 litres or more up to 900 litres or of 50 gallons or more up to 200 gallons¼% of known test quantity½% of known test quantity
  • (3) The limits of error set out in the following table apply to meters, generally of a size 75 mm or three inches or larger, that are used to measure liquids of high viscosity:

    TABLE

    Column IColumn IIColumn III
    ItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of Error
    1Any volume of 1 350 litres or more, or of 300 gallons or more3/16% of known test quantity3/8% of known test quantity
  • (4) The acceptance limits of error and in-service limits of error set out in the tables to subsections (2) and (3) apply to known test quantities equal to or greater than that delivered by the meter in one minute at maximum operating rate.

  • (5) The acceptance limits of error set out in Column II of the tables to subsections (2) and (3) apply only to tests under controlled conditions such as bench tests, and for tests for acceptance limits of error under other conditions, the limits of error set out in Column III of those tables shall apply.

  • SOR/89-570, s. 6(F)
  • SOR/2017-17, s. 17
  • SOR/2018-252, s. 6(F)
  •  (1) Subject to subsection (7), the limits of error set out in the tables to subsections (2) to (6) apply in respect of all meters that are designed to measure liquefied gases at ambient temperatures.

  • (2) The limits of error set out in the table to this subsection apply in respect of meters of a size from 25 mm to 50 mm or one inch to two inches, when tested using the liquefied gases the meters are intended to measure and using a narrow neck metal standard of the vapour displacement type.

    TABLE

    Column IColumn IIColumn III
    ItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of Error
    LitresGallons
    1225 or more50 or more0.5% of known test quantity1% of known test quantity
  • (3) The limits of error set out in the table to this subsection apply in respect of meters of a size 25 mm or larger or one inch or larger, except meters referred to in paragraph (4)(a), when tested using the liquefied gases the meters are intended to measure and using a pipe prover standard or master meter standard.

    TABLE

    Column IColumn IIColumn III
    ItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of Error
    LitresGallons
    1225 or more50 or more0.25% of known test quantity0.5% of known test quantity
  • (4) The limits of error set out in the table to this subsection apply in respect of

    • (a) meters used to dispense liquid propane to motor vehicles, when tested using the liquefied gases the meters are intended to measure and using a pipe prover standard or master meter standard; and

    • (b) meters of a size smaller than 25 mm or one inch, when tested using the liquefied gases the meters are intended to measure and using a pipe prover standard or master meter standard.

      TABLE

      Column IColumn IIColumn III
      ItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of Error
      LitresGallons
      1  5160 mL or 2 fluid ounces120 mL or 4 fluid ounces
      210285 mL or 3 fluid ounces170 mL or 6 fluid ounces
      320 or more4 or more0.5% of known test quantity1% of known test quantity
  • (5) The limits of error set out in the table to this subsection apply in respect of

    • (a) meters used to dispense liquid propane to motor vehicles, when tested using the liquefied gases the meters are intended to measure and using a gravimetric prover standard; and

    • (b) meters of a size smaller than 25 mm or one inch, when tested using the liquefied gases the meters are intended to measure and using a gravimetric prover standard.

      TABLE

      Column IColumn IIColumn III
      ItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of Error
      LitresGallons
      1from 25 to 45from 5 to 101.5%2%
      2more than 45more than 100.8%1%
  • (6) The limits of error set out in the table to this subsection apply in respect of meters of a size 25 mm or larger or one inch or larger, except meters referred to in paragraph (5)(a), when tested using the liquefied gases the meters are intended to measure and using a gravimetric prover standard.

    TABLE

    Column IColumn IIColumn III
    ItemKnown Test QuantityAcceptance Limits of ErrorIn-Service Limits of Error
    LitresGallons
    1from 100 to 200from 20 to 450.75%1%
    2more than 200more than 450.75%0.75%
  • (7) The acceptance limits of error set out in Column II of the tables to subsections (2) to (6) apply only in respect of tests made under controlled conditions, and for tests made under other conditions the limits of error set out in Column III of those tables apply.

  • SOR/89-570, s. 6(F)
  • SOR/90-118, s. 36
 