231 (1) A space that is used to store highly flammable liquids or liquefied gases must
(a) be kept clear of sources of heat; and
(b) prominently display signs bearing the following clearly legible words:
(i) “NO NAKED LIGHTS” and “PAS DE FLAMMES NUES”, and
(ii) “NO SMOKING” and “DÉFENSE DE FUMER”.
(2) Electrical wiring and fittings must not be installed within a space that is used to store highly flammable liquids or liquefied gases unless
(a) the installation is necessary for service within the space;
(b) the wiring and fittings are certified or type approved as being intrinsically safe by a product certification body that certifies electrical equipment for marine use or by a recognized organization; and
(c) the temperature of the exposed surface of the wiring and fittings does not exceed the ignition temperature of the explosive atmosphere that may exist in the space.