Multi-Sector Air Pollutants Regulations (SOR/2016-151)
Full Document:
- HTMLFull Document: Multi-Sector Air Pollutants Regulations (Accessibility Buttons available) |
- XMLFull Document: Multi-Sector Air Pollutants Regulations [629 KB] |
- PDFFull Document: Multi-Sector Air Pollutants Regulations [1179 KB]
Regulations are current to 2026-10-29 and last amended on 2026-01-01. Previous Versions
Marginal note:Modern heaters
7 (1) Subject to section 10, the NOx emission intensity of a modern heater — that, for a given hour, has at least 50% of the input energy in its combustion chamber resulting from the introduction of gaseous fossil fuel set out in column 1 of the table to this subsection and that has a difference between the temperature of its preheated air and the ambient air set out in column 2 must not, for that hour, exceed the limit set out in column 3.
TABLE
Modern Heaters — NOX Emission Intensity Limits
Column 1 Column 2 Column 3 Item Gaseous Fossil Fuel Difference between Temperature of Preheated Air and Ambient Air (°C) NOx Emission Intensity Limit (g/GJ) 1 Natural gas 0 16 2 Natural gas > 0 and ≤ 150 16 × [1 + (2 x 10-4T) + (7 x 10-6T2)], where T is the difference, expressed in °C, between the temperature of its preheated air and the ambient air 3 Natural gas > 150 19 4 Alternative gas 0 20.8 5 Alternative gas > 0 and ≤ 155 20.8 × [1 + (2 x 10-4T) + (7 x 10-6T2)], where T is the difference, expressed in °C, between the temperature of its preheated air and the ambient air 6 Alternative gas > 155 25 Marginal note:Preheated air
(2) For the purpose of subsection (1), the difference between the temperature of a modern heater’s preheated air and the ambient air, expressed in °C, for the given hour
(a) if there has been a determination of that difference made in accordance with section 24 within the previous 12 months, is the result of the most recent of such determination; and
(b) in any other case, is deemed to be 0°C.