Multi-Sector Air Pollutants Regulations (SOR/2016-151)

Regulations are current to 2026-10-29 and last amended on 2026-01-01. Previous Versions

Marginal note:Modern heaters

  •  (1) Subject to section 10, the NOx emission intensity of a modern heater — that, for a given hour, has at least 50% of the input energy in its combustion chamber resulting from the introduction of gaseous fossil fuel set out in column 1 of the table to this subsection and that has a difference between the temperature of its preheated air and the ambient air set out in column 2 must not, for that hour, exceed the limit set out in column 3.

    TABLE

    Modern Heaters — NOX Emission Intensity Limits

    Column 1Column 2Column 3
    ItemGaseous Fossil FuelDifference between Temperature of Preheated Air and Ambient Air (°C)NOx Emission Intensity Limit (g/GJ)
    1Natural gas016
    2Natural gas> 0 and ≤ 15016 × [1 + (2 x 10-4T) + (7 x 10-6T2)], where T is the difference, expressed in °C, between the temperature of its preheated air and the ambient air
    3Natural gas> 15019
    4Alternative gas020.8
    5Alternative gas> 0 and ≤ 15520.8 × [1 + (2 x 10-4T) + (7 x 10-6T2)], where T is the difference, expressed in °C, between the temperature of its preheated air and the ambient air
    6Alternative gas> 15525
  • Marginal note:Preheated air

    (2) For the purpose of subsection (1), the difference between the temperature of a modern heater’s preheated air and the ambient air, expressed in °C, for the given hour

    • (a) if there has been a determination of that difference made in accordance with section 24 within the previous 12 months, is the result of the most recent of such determination; and

    • (b) in any other case, is deemed to be 0°C.